User manual SKYPE 8512

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual SKYPE 8512. We hope that this SKYPE 8512 user guide will be useful to you.

Lastmanuals help download the user guide SKYPE 8512.


Mode d'emploi SKYPE 8512
Download
Manual abstract: user guide SKYPE 8512

Detailed instructions for use are in the User's Guide.

[. . . ] SKYE® A/C SERVICE EQUIPMENT & ACCESSORIES OWNERS MANUAL MODEL SKY8512 R12 A/C SERVICE CENTER RECOVER/RECYCLE/VACUUM/CHARGE WARNING: DO NOT MIX REFRIGERANTS April 12, 2001 SKYE® 2 A/C SERVICE EQUIPMENT & ACCESSORIES SKYE International Holdings, Inc. , 7441 Tower Street, Fort Worth TX. 76118 FOR TECHNICAL SUPPORT AND CUSTOMER SERVICE PLEASE CALL 1-800 722 SKYE (7593) RECORD YOUR EQUIPMENT DETAILS BELOW: MODEL NO. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] This does not mean that all the refrigerant has been recovered as there may be refrigerant trapped in the A/C system which will slowly evaporate. The compressor will restart automatically and recover this refrigerant. When the GAUGES remain at 0 PSI or below for at least 2 minutes recovery is complete. Note: The compressor will cycle ON/OFF due to internal machine pressure transition while performing the 2 minute outgas check. ) Close the low side and the high side manifold valves and proceed to the next step. If additional operations will be performed, continue to the next function. If no further operations are to be performed at this time, turn the FUNCTION SELECTOR to the OFF position and turn master power off. Drain the RECOVERED OIL into the measuring bottle by turning the RECOVERED OIL DRAIN VALVE to the OIL DRAIN position. This amount of new oil may be placed back into the A/C system. NOTE: If the unit stops during recovery and the RED TANK FULL light illuminates, your storage tank is full and must be replaced. All new tanks must be evacuated before use. EVACUATION (VACUUM) PROCEDURE 1. With power connected and both service hoses connected to the A/C system, turn the MASTER POWER SWITCH ON and turn the FUNCTION SELECTOR to the VACUUM position. Turn the VACUUM PUMP TIMER SWITCH to the desired operating time, the GREEN vacuum pump light will illuminate and the vacuum pump will turn on. (NOTE: The vacuum pump will not operate if there is pressure in the A/C system or unit plumbing. If this occurs, recover the refrigerant in the A/C system or unit plumbing and restart vacuum. ) 3. Open both manifold valves and evacuate the system for the set time. (NOTE: The scale may be programmed for the charge amount at this time. ) 5. When the evacuation is complete, close the gauge valves and check for vacuum leaks. 7 8 OIL CHARGE PROCEDURE IMPORTANT: THIS IS VACUUM SIDE OIL CHARGE. ONLY PUT THE AMOUNT OF OIL TO BE CHARGED IN THE BOTTLE FOR EACH JOB. ALLOW ENOUGH TIME FOR THE OIL TO CLEAR THE SERVICE HOSES BEFORE RESUMING VACUUM. Put the desired amount of oil in the bottle and start the vacuum operation. Allow the vacuum pump to run for 5 minutes then turn the VACUUM/OIL CHARGE valve to the CHARGE position (DO NOT TURN THE VACUUM PUMP OFF). The oil will be drawn into the A/C system by the vacuum in the A/C system. [. . . ] Refill the vacuum pump with SKYE Vacuum Pump Oil (PART # SA132) or a high quality vacuum pump oil unitl the oil level is even with the fill line on the nose of the pump. Replace the FILL plug and visually check for leaks. YOU ARE NOW READY TO BEGIN NORMAL SERVICE OPERATIONS TROUBLE SHOOTING CHART SYMPTOM Amber light on ­ Compressor won't run. Amber light on ­ compressor cycles on/off rapidly. Vacuum pump will not start. POSSIBLE CAUSE A/C system empty. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE SKYPE 8512

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual SKYPE 8512 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag