User manual SMC 6152L2

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual SMC 6152L2. We hope that this SMC 6152L2 user guide will be useful to you.

Lastmanuals help download the user guide SMC 6152L2.


Mode d'emploi SMC 6152L2
Download

You may also download the following manuals related to this product:

   SMC 6152L2 annexe 1 (6645 ko)
   SMC 6152L2 FICHE TECHNIQUE (1149 ko)

Manual abstract: user guide SMC 6152L2

Detailed instructions for use are in the User's Guide.

[. . . ] TigerSwitch 10/100 48-Port 10/100 Mbps Fast Ethernet Managed Switch 48 auto-MDI/MDI-X 10/100BASE-TX ports 4 Gigabit RJ-45 ports shared with 4 SFP transceiver slots Non-blocking switching architecture Spanning Tree Protocol, Rapid STP, and MSTP Up to 6 LACP or static trunks CoS support through four priority queues Full support for VLANs with GVRP IGMP multicast filtering and snooping Support for jumbo frames up to 9 KB Manageable via console, Web, SNMP, RMON Installation Guide Installationsanleitung SMC6152L2 TigerSwitch 10/100 Installation Guide From SMC's Tiger line of feature-rich workgroup LAN solutions 20 Mason Irvine, CA 92618 Phone: (949) 679-8000 February 2007 Pub. # 150000050600A Information furnished by SMC Networks, Inc. (SMC) is believed to be accurate and reliable. However, no responsibility is assumed by SMC for its use, nor for any infringements of patents or other rights of third parties which may result from its use. [. . . ] Untagged VLANs can be used for small networks attached to a single switch. However, tagged VLANs should be used for larger networks, and all the VLANs assigned to the inter-switch links. This switch also supports multiple spanning trees which allow VLAN groups to maintain a more stable path between all VLAN members. This can reduce the overall amount of protocol traffic crossing the network, and provide a shorter reconfiguration time if any link in the spanning tree fails. Figure 2-4 Making VLAN Connections Note: When connecting to a switch that does not support IEEE 802. 1Q VLAN tags, use untagged ports. 2-5 NETWORK PLANNING Application Notes 1. Full-duplex operation only applies to point-to-point access (such as when a switch is attached to a workstation, server or another switch). When the switch is connected to a hub, both devices must operate in half-duplex mode. Avoid using flow control on a port connected to a hub unless it is actually required to solve a problem. Otherwise back pressure jamming signals may degrade overall performance for the segment attached to the hub. As a general rule the length of fiber optic cable for a single switched link should not exceed: · · · 1000BASE-SX: 550 m (1805 ft) for multimode fiber. 1000BASE-LX: 5 km (3. 2 miles) for singlemode fiber. 1000BASE-ZX: 100 km (62. 1 miles) for singlemode fiber. However, power budget constraints must also be considered when calculating the maximum cable length for your specific environment. 2-6 CHAPTER 3 INSTALLING THE SWITCH Selecting a Site Switch units can be mounted in a standard 19-inch equipment rack or on a flat surface. Be sure to follow the guidelines below when choosing a location. · The site should: · be at the center of all the devices you want to link and near a power outlet. be able to maintain its temperature within 0 to 40 °C (32 to 104 °F) and its humidity within 10% to 90%, non-condensing provide adequate space (approximately two inches) on all sides for proper air flow be accessible for installing, cabling and maintaining the devices allow the status LEDs to be clearly visible Make sure twisted-pair cable is always routed away from power lines, fluorescent lighting fixtures and other sources of electrical interference, such as radios and transmitters. Make sure that the unit is connected to a separate grounded power outlet that provides 100 to 240 VAC, 50 to 60 Hz, is within 2. 44 m (8 feet) of each device and is powered from an independent circuit breaker. As with any equipment, using a filter or surge suppressor is recommended. · 3-1 INSTALLING THE SWITCH Ethernet Cabling To ensure proper operation when installing the switch into a network, make sure that the current cables are suitable for 10BASE-T, 100BASE-TX or 1000BASE-T operation. Check the following criteria against the current installation of your network: · Cable type: Unshielded twisted pair (UTP) or shielded twisted pair (STP) cables with RJ-45 connectors; Category 3 or better for 10BASE-T, Category 5 or better for 100BASE-TX, and Category 5, 5e or 6 for 1000BASE-T. Protection from radio frequency interference emissions Electrical surge suppression Separation of electrical wires (switch related or other) and electromagnetic fields from data based network wiring Safe connections with no damaged cables, connectors or shields RJ-45 Connector · · · · Figure 3-1 RJ-45 Connections 3-2 EQUIPMENT CHECKLIST Equipment Checklist After unpacking this switch, check the contents to be sure you have received all the components. Then, before beginning the installation, be sure you have all other necessary installation equipment. Package Contents · · · · · · · · TigerSwitch 10/100, SMC6152L2 Four adhesive foot pads Bracket Mounting Kit containing two brackets and eight screws for attaching the brackets to the switch Power Cord RS-232 console cable This Installation Guide Management Guide CD SMC Warranty Registration Card--be sure to complete and return to SMC Optional Rack-Mounting Equipment If you plan to rack-mount the switch, be sure to have the following equipment available: · · Four mounting screws for each device you plan to install in a rack--these are not included A screwdriver (Phillips or flathead, depending on the type of screws used) 3-3 INSTALLING THE SWITCH Mounting This switch can be mounted in a standard 19-inch equipment rack or on a desktop or shelf. Mounting instructions for each type of site follow. Rack Mounting Before rack mounting the switch, pay particular attention to the following factors: · Temperature: Since the temperature within a rack assembly may be higher than the ambient room temperature, check that the rack-environment temperature is within the specified operating temperature range 0 °C to 40 °C. Mechanical Loading: Do not place any equipment on top of a rack-mounted unit. Circuit Overloading: Be sure that the supply circuit to the rack assembly is not overloaded. [. . . ] The successor IEEE 802. 3 standard provides for integration into the OSI model and extends the physical layer and media with repeaters and implementations that operate on fiber, thin coax and twisted-pair cable. Fast Ethernet A 100 Mbps network communication system based on Ethernet and the CSMA/CD access method. Glossary-2 Full Duplex Transmission method that allows two network devices to transmit and receive concurrently, effectively doubling the bandwidth of that link. Gigabit Ethernet A 1000 Mbps network communication system based on Ethernet and the CSMA/CD access method. IEEE Institute of Electrical and Electronic Engineers. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE SMC 6152L2

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual SMC 6152L2 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag