User manual SMEG A1DN-7

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual SMEG A1DN-7. We hope that this SMEG A1DN-7 user guide will be useful to you.

Lastmanuals help download the user guide SMEG A1DN-7.


Mode d'emploi SMEG A1DN-7
Download
Manual abstract: user guide SMEG A1DN-7

Detailed instructions for use are in the User's Guide.

[. . . ] BEFORE CONNECTING THE DEVICE, MAKE SURE THAT IT HAS BEEN REGULATED FOR THE TYPE OF GAS THAT WILL FEED IT, CHECKING THE LABEL UNDER THE CASING. DO NOT PUT PANS WITHOUT PERFECTLY SMOOTH AND FLAT BOTTOMS ON THE COOKING HOB GRIDS. DO NOT USE RECIPIENTS OR GRIDDLE PLATES THAT EXTEND BEYOND THE EXTERNAL PERIMETER OF THE HOB. THE HOB IS TO BE USED BY ADULTS ONLY. DO NOT LET UNSUPERVISED CHILDREN PLAY WITH THE HOB. REPLACED APPLIANCES MUST BE TAKEN TO A SPECIAL GARBAGE COLLECTION CENTRE. The manufacturer declines all responsibility for damage to persons or things caused by non-observance of the above prescriptions or by interference with any part of the appliance or by the use of non-original spares. 20 Instructions for the installer 2. POSITIONING OF HOB The following operation requires building and/or carpentry work so must be carried out by a competent tradesman. Installation can be carried out on various materials such as masonry, metal, solid wood or plastic laminated wood as long as they are heat resistant (T 90°C). [. . . ] Refer to the coordinates shown in the figure, bearing in mind that sides A should be adjacent to the hole. Secure the hob to the counter with brackets B (supplied). Carefully trim any excess from border C of the gasket. The distances in the following drawing refer to the hole on the inner side of the gasket. 21 Instructions for the installer 3. ELECTRICAL CONNECTION Make sure that the voltage and capacity of the power line conform to the data shown on the plate located under the casing. Do not remove this plate for any reason. The plug on the end of the supply cable and the wall socket must be the same type and conform to the current electrical system regulations. Check that the power line is adequately grounded. On the power line, install an omnipolar cut-off device with contact cut-off distance greater than or equal to 3 mm, located in an easily accessible position near the unit. Do not use reducers, adapters or shunts. If the power cable is replaced, the wire section on the new cable must 2 not be less than 0. 75 mm (3 x 0. 75 cable), keeping in mind that the end to be connected to the hob must have the ground wire (yellow-green) longer by at least 20 mm. Use only H05V2V2-F cable or similar which has a maximum temperature of 90°C. ADAPTATION TO DIFFERENT TYPES OF GAS Before performing any cleaning or maintenance work, detach the appliance from the electrical socket. The hob has been inspected for G20 (2H) natural gas at a pressure of 20 mbar. For functioning with other types of gas the nozzles must be replaced and the primary air adjusted. To replace the nozzles and regulate the burners, you have to remove the top as described in the following paragraph. 5. 1 Removing the hob 1. Remove all the knobs, the grids, the burner caps and the flame-caps; remove the screws and the nuts A that secure the burner supports; remove plates B; lift the hob from its seat; replace the burner nozzles in accordance with the reference gas chart; regulate the primary air as described in paragraph "5. 2 Regulation for LPG". 25 Instructions for the installer 5. 2 Regulation for LPG Loosen screw A and push support B all the way. Use a double head wrench to remove nozzle C and assemble the suitable one, following the instructions indicated in the reference charts, with respect to the type of gas to use. The screwing torque of the nozzle should never exceed 3 Nm. Reposition support B so that nozzle C is covered perfectly. Move the Venturi tube D to regulate the air flow until distance "X" is reached indicated in the chart in paragraph "5. 4 Regulation of primary air" and then secure the tube by means of screw A. After the regulations have been carried out, restore the seals with sealing wax or equivalent material. Burner Rated heating capacity (kW) Nozzle diameter 1/100 mm 48 62 76 85 95 87 42 87 LPG ­ G30/G31 28/37 mbar Auxiliary (1) Semi-rapid (2) Average rapid (3) Large rapid (4) Triple crown (5) Triple crown (6) Double crown internal (7) external (7) 1. 05 1. 65 2. 55 3. 1 3. 9 3. 3 0. 8 3. 3 By-pass mm 1/100 30 33 (*) 30 33 (*) 37 40 (*) 45 65 65 26 33 (*) 55 Reduced flowrate (W) 380 380 750 800 1700 1700 380 1200 Flowrate g/h G30 76 120 185 225 283 240 58 240 Flowrate g/h G31 75 118 182 222 279 236 57 236 (*) By-pass value for valveless appliances. 26 Instructions for the installer 5. 3 Regulation for natural gas The hob has been inspected for G20 (2H) natural gas at a pressure of 20 mbar. To allow the unit to work with this type of gas, perform the same operations described in paragraph "5. 2 Regulation for LPG", but choose the nozzles and regulate the primary air for natural gas, as shown in the following table and in paragraph "5. 4 Regulation of primary air". After the regulations have been carried out, restore the seals with sealing wax or equivalent material. Burner Rated heating capacity (kW) Natural gas ­ G20 20 mbar Nozzle diameter 1/100 mm 73 92 115 126 140 130 67 130 Reduced flowrate (W) 380 380 750 800 1400 1400 380 1200 Auxiliary (1) Semi-rapid (2) Average rapid (3) Large rapid (4) Triple crown (5) Triple crown (6) Double crown internal (7) external (7) 1. 05 1. 65 2. 55 3. 1 3. 9 3. 3 0. 8 3. 3 5. 4 Regulation of primary air Referred to distance "X" in mm. BURNER G20 20 mbar 1. 5 1. 5 1 1. 5 2 1 9 1. 5 G30/G31 28/37 mbar 1 1. 5 1. 5 2. 5 3. 5 2. 5 1 8 Auxiliary (1) Semi-rapid (2) Average rapid (3) Large rapid (4) Triple crown (5) Triple crown (6) Double crown internal (7) external (7) 27 Instructions for the installer 6. [. . . ] The diameters of the by-passes for each burner are given in table "5. 2 Regulation for LPG". After having regulated the device with gas other than the one tested, replace the label located on the guard with the one that corresponds to the new gas. The label is inside the bag that contains the nozzles provided. 28 Instructions for the installer 6. 3 Arrangement of burners on hob BURNERS 1 2 3 4 5-6 7 Auxiliary Semi-rapid Average rapid Large rapid Triple crown Double crown 6. 4 Lubrication of gas taps After a while, the gas tap may become hard to turn or lock. If this happens, it has to be cleaned inside and re-greased. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE SMEG A1DN-7

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual SMEG A1DN-7 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag