User manual SMEG BQ91T-1

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual SMEG BQ91T-1. We hope that this SMEG BQ91T-1 user guide will be useful to you.

Lastmanuals help download the user guide SMEG BQ91T-1.


Mode d'emploi SMEG BQ91T-1
Download
Manual abstract: user guide SMEG BQ91T-1

Detailed instructions for use are in the User's Guide.

[. . . ] THE MANUFACTURER DECLINES ALL RESPONSIBILITY FOR IMPROPER USE. This kit sold separately is designed specifically for transformation of barbecue fuelling from GPL gas to METHANE gas. The kit includes all the components and the instructions necessary in order to make the modification. The appliance is factory set to run on GPL gas; to transform it (using the following kit) you must change the nozzles on all the burners, regulate the primary air only of the barbecue compartment burners and also regulate the minimum flame on the gas taps. [. . . ] Nozzle By-pass Reduced FlowFlowturns diameter 1/100 flowrate rate rate by-pass 1/100 mm (W) g/h G30 g/h G31 mm closed 100 2200 85 327 321 closed closed 1 + 1/4 1 + 1/4 closed closed 100 100 95 105 85 50 Left Centre (BQ91T) 4. 5 4. 5 4. 5 3. 8 4. 5 3. 0 1. 05 85 85 Reg. 45 30 2200 2200 2500 2700 800 400 327 327 276 327 218 76 321 321 271 321 214 75 Right Radiating grill Radiating grill (BQ91T) Rapid (BQ6130T) Auxiliary (BQ6130T) In the column no. turns by-pass, closed means screwed in fully. Burner Rated heating capacity (kW) Methane gas ­ G20 20 mbar no. turns by-pass Nozzle diameter 1/100 mm 150 150 150 145 155 108 72 Reduced flowrate (W) 2200 2200 2200 2500 2700 800 400 Left Centre (BQ91T) Right Radiating grill Radiating grill (BQ91T) Rapid (BQ6130 - S) Auxiliary (BQ6130 - S) 4. 5 4. 5 4. 5 3. 8 4. 5 3. 0 1. 05 360° + 90° 360° + 90° 360° + 90° 360° + 360° 720° + 180° 180° 180° 12 Instructions for the installer BQ61 - BQ6130 - BQ91 - BQ61S - BQ6130S - BQ91S Burner Rated heating capacity (kW) LPG ­ G30/G31 30/37 mbar no. Nozzle By-pass Reduced Flow- Flowrate turns diameter 1/100 flowrate rate g/h G31 by-pass 1/100 mm (W) g/h G30 mm closed 80 1800 75 218 214 closed closed closed closed closed closed 80 80 80 80 85 50 Left Centre left (BQ91S - BQ91) 3. 0 3. 0 3. 0 3. 0 3. 0 3. 0 1. 05 75 75 75 75 45 30 1800 1800 1800 1800 800 400 218 218 218 218 218 76 214 214 214 214 214 75 Centre Centre right (BQ91S - BQ91) Right Rapid (BQ6130 - S) Auxiliary (BQ6130 - S) In the column no. turns by-pass, closed means screwed in fully. Burner Rated heating capacity (kW) Methane gas ­ G20 20 mbar rotation by-pass Nozzle diameter 1/100 mm 123 123 123 123 123 115 72 Reduced flowrate (W) 1800 1800 1800 1800 1800 800 400 Left Centre left (BQ91S - BQ91) Centre Centre right (BQ91S - BQ91) Right Rapid (BQ6130 - S) Auxiliary (BQ6130 - S) 3. 0 3. 0 3. 0 3. 0 3. 0 3. 0 1. 05 315° 315° 315° 315° 315° 180° 180° 13 Instructions for the installer CHANGING THE NOZZLES CHANGING THE BURNER COMPARTMENT NOZZLES 1 Remove the grills and refractory plates (where present) located inside the barbecue compartment. 2 Unscrew the screw(s) (for each burner) located on the rear crosspiece. 3 Remove the burners from the barbecue compartment. 4 Using a 7mm socket wrench, unscrew the nozzles positioned on the taps (Change the nozzles according to the table provided above). 5 Regulate the air (see primary air adjustment). 6 Replace the burners correctly and screw the holding screws. CHANGING THE RADIATING GRILL NOZZLES (ONLY ON MODELS BQ61T - BQ6130T - BQ91T) Remove the rear part of the barbecue by unscrewing the support screws. 2 Using a 7mm wrench unscrew the nozzle (1). 3 Change the nozzles according to the table provided above. [. . . ] If the minimum flame is not regular, remove the knob and move the by-pass with small clockwise or counter-clockwise turns and repeating the flame stability check. If the flame is regular, the minimum adjustment operation has been successful. 3 4 5 6 CONVERSION FROM METHANE GAS TO GPL GAS Carry out the following operations on all the gas taps. Turn the by-pass inside, screwing it in fully. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE SMEG BQ91T-1

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual SMEG BQ91T-1 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag