[. . . ] current category III, in accordance with installation instructions. IMPORTANT: Before re-connecting the hood circuit to the mains supply and checking the efficient function, always check that the mains cable is correctly assembled and that it has NOT remained crushed inside the compartment of the same during the installation stage.
Mounting
The hood is supplied in two versions: model for installation to the wall and model for installation to the ceiling. Before beginning installation: · Check that the product purchased is of a suitable size for the chosen installation area. · To facilitate installation, remove the fat filters and the other parts allowed and described here, dismantle and mount it. [. . . ] Note: in positioning and fixing the reinforcement bracket(s) check that these do not impede easy fixing of the discharge tube (aspiration version) or the deflector (filtering version). Apply the perforation diagram of the ceiling on the vertical of the cooking top (the centre of the scheme must correspond to the centre of the cooking top and the sides must be parallel to the sides of the cooking top the side of the scheme with the word FRONT corresponds to the control panel side). Make holes as indicated (6 holes for 6 wall dowels 4 dowels for the hook), screw 4 screws into the external holes leaving a space between the head of the screw and the ceiling of about 1cm. Introduce a discharge tube into the trellis and connect to the connection ring of the motor space (discharge tube and fixing band not supplied). The discharge tube must be sufficiently long to reach the outside (aspiration version) or the deflector (filtering version). Only for filtering version: mount deflector F on the trellis and fix it with 4 screws to the apposite bracket and, finally, connect the discharge tube to the connection ring on the deflector. Hook the trellis to the ceiling with the 4 screws (see operation 4). Introduce and screw another two screws up decisively into the holes for safety fixing remaining free. Connect the electricity to the domestic power. The electricity supply must be connected only after installation has been completed. Insert 2 pegs at the sides of the fixing points between the
trellis and the hood. Apply the flues support bracket G to the wall adherent to the ceiling, use the flues support bracket as a perforation diagram (if present, the small slot on the support must coincide with the line drawn previously on the wall) and mark two holes with a pencil. Make the holes (Ø8mm), and insert 2 dowels. Fix the chimney support bracket to the wall using two 5x45mm screws. Fix the hood into its final position on the wall (ABSOLUTELY ESSENTIAL). Connect a pipe (pipe and pipe clamps not provided, to be purchased separately) for discharge of fumes to the connection ring located over the suction motor unit. If the hood is to be used in ducting version, the other end of the pipe must be connected to a device expelling the fumes to the outside. If the hood is to be used in filter version, then fix the deflector F to the chimney support bracket G and connect the other extremity of the pipe to the connection ring placed on the deflector F. Apply the chimney stacks and fasten them at the top to the chimney support G (17b) using 2 screws (17a) 18. Slide the bottom section of the chimney down until it completely covers the suction unit and slots into the housing provided on top of the hood. Remount the carbon filter frame and the fat/s filter/s and check the perfect functioning of the hood. Air outlet (used for filter version only)
Operation
Use the high suction speed in cases of concentrated kitchen vapours. [. . . ] To put into function the greasyfilter signal:: Set the cooker-hood off, press switch button no. 6 for more than 3 seconds ( the switch will turn on red signalling that the function has been set. 3 It is possible to use a traditional carbon filter, neither washable nor regenerable, to be replaced every 3 - 4 months. The filter holder frame of the carbon filter is welded together; the eventual frame supplied with the hood is not, therefore, to be used. Insert it into its housing and fix it turning the 2 plastic knobs.
Replacing lamps
Disconnect the hood from the electricity. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE SMEG CB61VGY
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.