Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual SMEG CIR60X. We hope that this SMEG CIR60X user guide will be useful to you.
Lastmanuals help download the user guide SMEG CIR60X.
Detailed instructions for use are in the User's Guide.
[. . . ] INSTRUCTIONS FOR SAFE AND PROPER USE________________ 4 POSITIONING OF HOB ____________________________________ 6 GAS CONNECTION ______________________________________ 11 ELECTRICAL CONNECTION ______________________________ 12 GAS CONNECTION ______________________________________ 13 ADAPTATION TO DIFFERENT TYPES OF GAS _______________ 15 FINAL OPERATIONS _____________________________________ 17 USING THE HOB ________________________________________ 19 CLEANING AND MAINTENANCE ___________________________ 22 PROBLEMS AND CAUSES ________________________________ 24
Thank you for choosing our product. We advise you to read this manual carefully. It contains all necessary instructions for maintaining unaltered the appearance and functional qualities of the hob. INSTRUCTIONS FOR THE INSTALLER: these are for the authorised persons who must carry out a suitable check of the gas system, install the appliance, set it functioning and carry out an inspection test. [. . . ] The regulator supplied must be fitted to the ½ BSP thread at the rear of the appliance. An approved manual shut-off valve must be installed. regulator must be checked and adjusted to 1. 0kPa after installation. ULPG: Can be connected to the inlet fitting directly. The pressure must be checked to ensure it is operating at 2. 75kPa. A separate test point fitting must be installed between the piping & the appliance for the pressure to be checked to ensure it is operating at 2. 75kPa.
11
Instructions for the installer
4. ELECTRICAL CONNECTION
Make sure that the voltage and capacity of the power line conform to the data shown on the plate located under the casing. Do not remove this plate for any reason. The plug on the end of the supply cable and the wall socket must be the same type and conform to the current electrical system regulations. Check that the power line is adequately grounded. On the power line, install an omnipolar cut-off device with contact cut-off distance greater than or equal to 3 mm, located in an easily accessible position near the unit. Do not use reducers, adapters or shunts.
If the power cable is replaced, the wire section on the new cable must not be less than 1. 5 mm2 (3 x 1. 5 cable), keeping in mind that the end to be connected to the hob must have the ground wire (yellow-green) longer by at least 20 mm. Use only H05V2V2-F cable or similar which has a maximum temperature of 90°C. Any replacement needed should be carried out by a specialised technician who should make the mains connections according to the following diagram. L = brown N = blue = yellow-green
The manufacturer will not be liable for any damage to persons or property caused by non-observance of the above instructions or deriving from the tampering of even a single part of the hob.
12
Instructions for the installer
5. The room where the oven is installed should be suitably ventilated to avoid overheating or excess humidity produced by cooking, and in the case of lengthy use a window should be opened or the speed of any ventilators should be increased.
5. 3 Discharge of combustion products
Discharge of combustion products must be guaranteed by means of hoods connected to a natural draught flue with certain efficiency, or by means of forced aspiration. An efficient aspiration system requires careful planning by a specialist capable of installing it, respecting the positions and distances prescribed by standards. After installation, the installer must issue a certificate of conformity.
14
Instructions for the installer
6. ADAPTATION TO DIFFERENT TYPES OF GAS
Before performing any cleaning or maintenance work, detach the appliance from the electrical socket.
The hob has been inspected for NG natural gas at a pressure of 1. 0 kPa. For functioning with other types of gas the nozzles must be replaced and the primary air adjusted. To replace the nozzles and regulate the burners, you have to remove the top as described in the following paragraph.
6. 1 Removing the hob
1. Remove all the knobs, the grids, the burner caps and the flame-caps; remove the screws and the nuts A that secure the burner supports; remove plates B; lift the hob from its seat; replace the burner nozzles in accordance with the reference gas chart; regulate the primary air as described in paragraph "6. 2 Regulation for LPG".
15
Instructions for the installer
6. 2 Regulation for LPG
Loosen screw A and push support B all the way. [. . . ] How to use: pour the product on a damp cloth and wipe the surface, rinse thoroughly and dry with a soft cloth or deerskin. 9. 1. 2 Food stains or residues Do not use metallic sponges or sharp scrapers: they will damage the surface. Use normal non-abrasive products and remove spots or residuals with non-scratch sponges or, if need be, with wood or plastic utensils. Rinse thoroughly and dry with a soft cloth or deerskin.
9. 2 Cleaning of cooking hob components
Grids, caps, flame cap crowns and burners can be removed for ease of cleaning. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE SMEG CIR60X
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.