Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual SMEG CIR60X3. We hope that this SMEG CIR60X3 user guide will be useful to you.
Lastmanuals help download the user guide SMEG CIR60X3.
Detailed instructions for use are in the User's Guide.
[. . . ] INSTRUCTIONS FOR SAFE AND PROPER USE________________ 4 POSITIONING OF HOB ____________________________________ 6 GAS CONNECTION ______________________________________ 11 ELECTRICAL CONNECTION ______________________________ 12 ADAPTATION TO DIFFERENT TYPES OF GAS _______________ 13 FINAL OPERATIONS _____________________________________ 16 USING THE HOB ________________________________________ 18 CLEANING AND MAINTENANCE ___________________________ 21 PROBLEMS AND CAUSES ________________________________ 24
Thank you for choosing our product. We advise you to read this manual carefully. It contains all necessary instructions for maintaining unaltered the appearance and functional qualities of the hob.
INSTRUCTIONS FOR THE INSTALLER: these are for the authorised persons who must carry out a suitable check of the gas system, install the appliance, set it functioning and carry out an inspection test. INSTRUCTIONS FOR THE USER: these contain user advice, description of the commands and the correct procedures for cleaning and maintenance of the appliance.
3
Introduction
1. [. . . ] Warranty service calls do not cover these adjustments!To check the operating pressure of the appliance it is recommended at least 2 large size burners are used. Ensure appliance is secured to wall when installation is completed. The regulator supplied must be fitted to the ½ BSP thread at the rear of the appliance. An approved manual shut-off valve must be installed. regulator must be checked and adjusted to 1. 0kPa after installation. Can be connected to the inlet fitting directly. The pressure must be checked to ensure it is operating at 2. 75kPa. A separate test point fitting must be installed between the piping & the appliance for the pressure to be checked to ensure it is operating at 2. 75kPa.
11
Instructions for the installer
4. ELECTRICAL CONNECTION
Make sure that the voltage and capacity of the power line conform to the data shown on the plate located under the casing. Do not remove this plate for any reason. The plug on the end of the supply cable and the wall socket must be the same type and conform to the current electrical system regulations. Check that the power line is adequately grounded. On the power line, install an omnipolar cut-off device with contact cut-off distance greater than or equal to 3 mm, located in an easily accessible position near the unit. Do not use reducers, adapters or shunts.
If the power cable is replaced, the wire section on the new cable must not be less than 1. 5 mm2 (3 x 1. 5 cable), keeping in mind that the end to be connected to the hob must have the ground wire (yellow-green) longer by at least 20 mm. Use only H05V2V2-F cable or similar which has a maximum temperature of 90°C. Any replacement needed should be carried out by a specialised technician who should make the mains connections according to the following diagram. L = brown N = blue = yellow-green
The manufacturer will not be liable for any damage to persons or property caused by non-observance of the above instructions or deriving from the tampering of even a single part of the hob.
12
Instructions for the installer
5. FINAL OPERATIONS
Having carried out the above adjustments, reassemble the appliance following, backwards, the instructions in paragraph "6. 1 Removing the hob".
6. 1 Regulation of minimum for natural gas
Replace the components on the burner and slide the knobs on the gas tap pins. Light the burner and set it at minimum position. Remove the knob and turn the regulation screw inside or next to the gas tap pin (depending on the model) until you get a suitable minimum flame. Replace the knob and check burner flame stability: (rapidly turning the knob from maximum to minimum position, the flame should not go out).
6. 2 Regulation of minimum for LPG
To regulate the minimum for LPG, completely tighten (clockwise) the screw inside or next to the gas tap pin (depending on the model). [. . . ] Your local authorised after-sales technician is able to supply professional products for appliance cleaning and care. Grids, caps, flame cap crowns and burners can be removed for ease of cleaning. Wash them in warm water using a non-abrasive detergent, taking care to remove all tough spots. Before remounting, allow the components to fully dry out. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE SMEG CIR60X3
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.
Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual SMEG CIR60X3 will begin.