User manual SMEG DGS60W

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual SMEG DGS60W. We hope that this SMEG DGS60W user guide will be useful to you.

Lastmanuals help download the user guide SMEG DGS60W.


Mode d'emploi SMEG DGS60W
Download
Manual abstract: user guide SMEG DGS60W

Detailed instructions for use are in the User's Guide.

[. . . ] SHOULD THE APPLIANCE NOT FUNCTION, DISCONNECT IT FROM THE SUPPLY AND CALL THE NEAREST TECHNICAL ASSISTANCE CENTRE. ALWAYS CHECK THAT THE CONTROL KNOBS ARE IN THE POSITION "ZERO" (OFF) WHEN YOU FINISH USING THE HOB. 22 Introduction THE IDENTIFICATION PLATE, WITH TECHNICAL DATA, SERIAL NUMBER AND MARKING IS CLEARLY VISIBLE UNDER THE CASING. THE PLATE ON THE CASING MUST NOT BE REMOVED. BEFORE CONNECTING THE DEVICE, MAKE SURE THAT IT HAS BEEN REGULATED FOR THE TYPE OF GAS THAT WILL FEED IT, CHECKING THE LABEL UNDER THE HOB. [. . . ] Keep a minimum distance of 10 mm between the bottom of the unit and the panel surface. The panel has to be easily removable to allow access in the event of technical service. 25 Instructions for the installer 3 ELECTRICAL CONNECTION Make sure that the voltage and capacity of the power line conform to the data shown on the plate located under the casing. Do not remove this plate for any reason. The plug on the end of the supply cable and the wall socket must be the same type and conform to the current electrical system regulations. Check that the power line is adequately grounded. On the power line, install an omnipolar cut-off device with contact cutoff distance greater than or equal to 3 mm, located in an easily accessible position near the unit. Do not use reducers, adapters or shunts. If the power cable is replaced, the wire section on the new cable must not be less than 1. 0 mm 2 (3 x 1. 0 cable), keeping in mind that the end to be connected to the hob must have the ground wire (yellow-green) longer by at least 20 mm. Use only H05V2V2-F cable or similar which has a maximum temperature of 90°C. Any replacement needed should be carried out by a specialised technician who should make the mains connections according to the following diagram. L = brown N = blue = yellow-green The manufacturer will not be liable for any damage to persons or property caused by non-observance of the above instructions or deriving from the tampering of even a single part of the hob. 26 Instructions for the installer 4 GAS CONNECTION Connection to the gas mains may be made with a rigid copper pipe or with a flexible pipe and conforming to the provisions defined by standard regulations in force. To facilitate connection, fitting A on the rear of the appliance may be adjusted laterally. After the regulations have been carried out, restore the seals with sealing wax or equivalent material. Burner Rated heating capacity LPG ­ G30/G31 28/37 mbar Nozzle diameter By-pass 1/100 mm 1/100 mm 48 30 (1) 62 30 (1) 76 37 (2) 85 43 67 43 (3) 87 55 (4) 48 30 (1) 92 55 (4) Reduced flowrate (W) Flowrate g/h G30 Flowrate g/h G31 Auxiliary (1) Semirapid (2) Rapid (3) Rapid large (4) Fish pan (7) Ultra rapid (5) Double Internal crown External (6) 1. 05 1. 65 2. 55 3. 1 2 3. 3 1. 15 3. 8 380 380 650 750 750 1200 380 1200 76 120 185 225 145 240 84 276 75 118 182 222 143 236 82 271 (1)= 33 for valveless appliances. (4)= 65 for valveless appliances. 30 Instructions for the installer 5. 3 Regulation for natural gas The hob has been inspected for G20 (2H) natural gas at a pressure of 20 mbar. To allow the unit to work with this type of gas, perform the same operations described in paragraph "5. 2 Regulation for LPG", but choose the nozzles and regulate the primary air for natural gas, as shown in the following table and in paragraph "5. 5 Regulation of primary air". After the regulations have been carried out, restore the seals with sealing wax or equivalent material. Rated heating Burner Natural gas ­ G20 20 mbar capacity Nozzle diameter Reduced flowrate 1/100 mm (W) Auxiliary (1) 1. 05 73 380 Semirapid (2) 1. 65 92 380 Rapid (3) 2. 55 115 650 Rapid large (4) 3. 1 126 750 Fish pan (7) 2. 0 100 750 Ultra rapid (5) 3. 3 130 1200 Double Internal 1. 05 73 380 crown External 3. 9 140 1200 (6) 5. 4 Regulation for town gas To allow the unit to work with this type of gas, perform the same operations described in paragraph "5. 2 Regulation for LPG", but choose the nozzles and regulate the primary air for town gas, as shown in the following table and in paragraph "5. 5 Regulation of primary air". Only units with safety valves can be used with town gas G110. Rated heating Burner Town Gas 110 - 8 mbar capacity Nozzle diameter Reduced flowrate 1/100 mm (W) Auxiliary (1) 1. 05 132 380 Semirapid (2) 1. 65 165 380 Rapid (3) 2. 55 210 650 Rapid large (4) 3. 1 240 750 Fish pan (7) 2 190 750 Ultra rapid (5) 3. 3 250 1200 1. 05 132 380 Double crown Internal (6) External 3. 9 290 1200 31 Instructions for the installer 5. 5 Regulation of primary air G30/G31 30/37 mbar 1. 0 1. 5 1. 5 10. 0 2. 5 2. 5 6. 0 10. 0 G110 8 mbar 0. 5 0. 5 1. 0 1. 5 1. 0 1. 5 1. 0 5. 0 Referred to distance "X" in mm. G20 Burner 20 mbar Auxiliary (1) Semirapid (2) Rapid (3) Rapid large (4) Fish pan (7) Ultra rapid (5) Double crown (6) Internal External 1. 5 1. 5 1. 0 2. 5 2. 0 2. 0 3 3. 0 To identify the burners on your hob, refer to the drawings in point "6. 3 Arrangement of burners on hob " 32 Instructions for the installer 6 FINAL OPERATIONS Having carried out the above adjustments, reassemble the appliance following, backwards, the instructions in paragraph "5. 1 Removing the hob". 6. 1 Regulation of minimum for natural gas Replace the components on the burner and slide the knobs on the gas tap pins. Light the burner and set it at minimum position. Remove the knob and turn the regulation screw inside or next to the gas tap pin (depending on the model) until you get a suitable minimum flame. Replace the knob and check burner flame stability: (rapidly turning the knob from maximum to minimum position, the flame should not go out). 6. 2 Regulation of minimum for LPG To regulate the minimum for LPG, completely tighten (clockwise) the screw inside or next to the gas tap pin (depending on the model). [. . . ] In normal use of the hob, the stainless steel burner caps and panstands tend to be burnished by the high temperature. Clean these parts using very fine abrasive sponges or similar commercial products. Then use a specific paste polish to restore the steel's shine. Your local authorised after-sales technician is able to supply professional products for appliance cleaning and care. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE SMEG DGS60W

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual SMEG DGS60W will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag