User manual SMEG GM274-110

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual SMEG GM274-110. We hope that this SMEG GM274-110 user guide will be useful to you.

Lastmanuals help download the user guide SMEG GM274-110.


Mode d'emploi SMEG GM274-110
Download
Manual abstract: user guide SMEG GM274-110

Detailed instructions for use are in the User's Guide.

[. . . ] · Deep fat fryers must be continuously monitored during use: overheated oil can burst into flames. · The hood should not be used by children or persons not instructed in its correct use. MAINTENANCE · Switch off or unplug the appliance from the mains supply before carrying out any maintenance work. · Clean and/or replace the Filters after the specified time period. [. . . ] · For the power supply cable feed, drill ø 10 mm. · For the air outlet (Ducted Version), drill according to the diameter of the external air exhaust duct connection. FIXING THE FRAME Before fixing, separate the Upper Section 2. 1 and the Lower Section 2. 2 from the Frame by unscrewing the screws 12c, then separate the two sections of the frame by unscrewing the 6 side screws to obtain the Upper frame and Lower frame. GB 16 Upper frame · Align the power supply cable feed hole · Fix the upper frame to the ceiling or shelf using: · For concrete ceilings, use the appropriate plugs for the screw size (not provided). · For hollow brick ceilings of wall thickness of approximately 20 mm: use 4 plugs 11 and 4 screws 12h, provided. · For wooden beam ceilings, use 4 wood screws (not provided). · For wooden shelf, use 4 screws 12g with washers 22 and nuts 23, provided. Lower frame · Fix the lower frame using the 8 previously removed screws, adjusting the length according to the installation height (hood body lower fixing surface must be at least 720 mm from the hob). · For the recirculation version, turn the frame in the direction chosen for the recirculated air outlet. · The frame mountings must be secure to withstand the weight of the hood and any stresses caused by the occasional side thrust applied to the device. On completion, check that the base is stable, even if the frame is subjected to bending. · In all cases where the ceiling is not strong enough at the suspension point, the installer must provide strengthening using suitable plates and backing pieces anchored to the structurally sound parts. Connections DUCTED VERSION AIR EXHAUST SYSTEM When installing the ducted version, connect the hood to the chimney using either a flexible or rigid pipe ø 150 or 120 mm, the choice of which is left to the installer. Switches the extractor motor on and off at low speed. Used to provide a continuos and silent air change in the presence of light cooking vapours. When the Hood is in ELC (Electronic Comfort) mode, the button will not only turn the Ducting motor on, but will also disable this function. V1 Speed Reduces the operating speed. When the button is pressed with the Motor off, ELC (Electronic Comfort) mode will be enabled again, giving a continuous, low noise flow of air. Press the button and hold it until Led S1 flashes slowly. V2 V3 Speed Intensive speed Increases the operating speed. Maximum speed, used for eliminating the highest cooking vapour emission. Switches off automatically after 10 minutes operation. Can also be switched off manually by pressing the button. GB 19 MAINTENANCE Grease filters CLEANING METAL SELF-SUPPORTING GREASE FILTERS Alarm signal reset · Switch off the lights and extractor motor. · Press button V3 for at least 3 seconds, until the leds start to flash. Cleaning the filters · The filters are washable and must be cleaned when led S1 flashes or at least every 2 months of operation, or more frequently for particularly heavy usage. · Remove the filters one at a time by pushing them towards the back of the group and pulling down at the same time. [. . . ] · Press button V3 for at least 10 seconds, until the leds start to flash: · 2 flashes of the activated carbon odour filter saturation alarm led = filter ACTIVATED · 1 flash of the activated carbon odour filter saturation alarm led = filter DEACTIVATED Lighting LIGHT REPLACEMENT 20 W halogen light. · Remove the 2 screws fixing the ring nut. · Extract the lamp from the lamp holder by pulling gently. · Replace with another of the same type, making sure that the two pins are properly inserted in the lamp holder socket holes. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE SMEG GM274-110

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual SMEG GM274-110 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag