[. . . ] Make sure the room is properly ventilated when using the hood and other gas appliances at the same time. Comply with the regulations on air discharge when operating the hood. The extracted air must not be routed into a duct used to discharge fumes of gasoperated appliances.
·
· · · · · · · ·
·
·
This appliance must not be used by children without an adult supervision and disabled people may require assistance.
THE MANUFACTURER CANNOT BE HELD RESPONSIBLE IF THE ABOVE INSTRUCTIONS ARE NOT FOLLOWED.
OPERATION
This appliance has been designed to work as a DUCTING hood (evacuation of the air) or RECYCLING hood (recycling of the filtered air). · DUCTED MODE: In order to use the hood in the ducted mode, connect the motor intake, by means of a suitable ducting hose not less than 120mm diameter, directly to the external fumes outlet. [. . . ] Put the chimney bracket K on the B chimney (fig. Mark the holes on the wall for fixing the chimney bracket to the wall. Remove the chimney set, drill and fix the support bracket to the wall by means of wall anchors. Put the chimney group back in place and fix it to the hood with the Z screws and to the chimney bracket with the L screws as shown in figure 6.
Fig. 5
ELECTRICAL CONNECTION It is recommended that all electrical connection operations are performed by a qualified technician.
Fig. 6 K
B
The appliance is supplied WITHOUT A PLUG. It is therefore necessary to fix a plug to the cable or hard wire direct to a spur. The plug and fuse must be in accordance with the rating plate inside the hood. Then connect it to a nearby, easily reachable socket in accordance with the rules in force. In the case of a direct connection to the mains supply, it is necessary to put a switched spur between the appliance and the mains supply. The switch must be suitable for the load, compliant with the rules in force and must have a minimum contact opening of not less than 3mm.
Z Z
EN
03
OPERATING INSTRUCTIONS: ü
CONTROL PANEL:
In order to achieve the best performance, it is recommended to start the hood a few minutes before starting cooking and keep it on for at least 15 minutes after finishing cooking or after all fumes and odours have disappeared. To start the hood, identify your type of control panel and follow the instructions:
Ø SLIDER:
A
B
- Key (A) to turn on/off the hood's light. - Four-position Cursor (B): 0: Off 1/2/3: On/Speed adjustment
(A)
(B)
Ø ELECTROMECHANICAL PUSHBUTTONS:
0 1-2-3
Light ON/OFF Button Motor OFF button On/speed adjustment button
Ø WITH KNOBS :
- Two-position Knob (A) to turn on/off
the light (0-1)
- Four-position Knob (B):
0 Motor OFF 1-2-3 Speed adjustment
(A)
(B)
EN
04
Ø ELECTRONIC PUSHBUTTONS: Lights ON/OFF
0/1 2-3-4
OFF/1 speed Speed adjustment
Filters reset button OPTIONAL FUNCTIONS: - AUTO POWER-OFF TIMER: Pushing one of the speed adjustment buttons (2-3-4) twice, you will activate the "Auto power-off timer" function that turns the motor and light off after 10 mins. The activation of such function is signalled by the blinking LED
above the pressed button.
- FILTERS CLEANING WARNING: When all the 4 LEDs blink at the same time (which is programmed to happen every 100h of operation), the user is required to clean/replace the filters .
Pressing the Reset button
the 100h count will start again
Note: Pressing the reset button accidentally before the end of the 100h cycle does not reset the filters cleaning memory It is recommended that grease filters are cleaned every 100h and active carbon filters are replaced every 200h.
CLEANING AND MAINTENANCE:
Before performing any cleaning and/or maintenance operation always disconnect the hood from the mains supply. Regular cleaning will ensure a good performance and extend the working life of the hood. Special attention should be given to the grease filters and carbon filters (for recycling hoods only). Note: An excess of grease in the filter, as well as affecting the performance of the hood, can also be a fire risk. EXTERNAL CLEANING: External and internal cleaning of the hood should be performed with a damp cloth and a non-bleach liquid detergent, absolutely avoiding solvents or abrasive substances. It is advisable to use specific products, following their instructions. When cleaning the steel of the hood, we suggest rubbing in the same direction as the grain.
EN
05
METAL FILTERS CLEANING: Special attention should be reserved to the metal grease filters. [. . . ] Once the fixture has been removed, remove the biax lamp from its seat and support. Put a new lamp in, performing the same operations backwards.
d)
Neon lamp: 15/18W neon tube. To reach the neon tube, unscrew the glass framework screws. Rotate the tube 90 degrees and remove the neon lamp. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE SMEG KAP700X
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.