[. . . ] EN
Specific Instruction Manual
EN
Installation instructions:
EN
Grease filter extraction instructions.
Top removable glass
Bottom removable glass
1)Top glass extraction phases:
NB: Extract the bottom glass in the same manner.
EN
2) Grease filter extraction:
To remove the metal grease filter, follow the instructions carried in the General Instruction Booklet.
EN
Electronic control system instructions for use:
Technical Features:
· Power supply from mains: 230 VAC 50/60 Hz · Power consumption in standby: 20 mA · Max. load applicable to LIGHTS connection: 150 W · Max. [. . . ] · SPEED Reduces motor speed: V4 V3 V2 V1 · SPEED + Increases motor speed: V1 V2 V3 V4 · BOOST-SPEED MODE Enables BOOST-SPEED mode from any motor speed or when motor is off. To disable BOOST-SPEED, press the button again and stop the motor. BOOST-SPEED mode is set to operate for 10 minutes: during which the display alternatively shows HI and the remaining time and the dot at the bottom right flashes every second. After 10 minutes the system automatically reverts to the previous speed setting. · 24H AIR CHANGE Starts the blower motor at a speed that provides a flow rate of about 100 m3/h. When 24h AIR CHANGE is enabled the display shows 24. 24h AIR CHANGE cannot be enabled when either BOOST-SPEED or DELAY -OFF is enabled. · DELAY Enables and disables the hood's complete shutdown (motor+lights) after 30 minutes: during which the display alternatively shows the motor speed and the minutes remaining and the dot at the bottom right flashes every second.
EN
To disable the DELAY press the button again or stop the motor. · RESET FILTRI: Resets the filter saturation alarm if pressed for 2s when all the loads (motor+lights) are off. · If there is a metal Filter sat. alarm, FF appears on the display, after 100 h of operation. · If there is a CA filter alarm, EF appears on the display after 200h of operation. [. . . ] ACCESSING THE SET-UP PROCEDURE: 1) To access the set-up procedure press button 24 for about 5s, until an animation appears on the display; when the animation starts you have about 5 seconds to perform the set-up: · Press V- to enable/disable the A. C. filter saturation alarm EF flashes twice when enabled and once when disabled .
EN
· Press button 24 to enable/disable the remote control receiver; "tc" flashes twice on the display when the remote has been enabled and once when the remote control has been disabled. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE SMEG KCVB9SG
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.