User manual SMEG KEIV90

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual SMEG KEIV90. We hope that this SMEG KEIV90 user guide will be useful to you.

Lastmanuals help download the user guide SMEG KEIV90.


Mode d'emploi SMEG KEIV90
Download
Manual abstract: user guide SMEG KEIV90

Detailed instructions for use are in the User's Guide.

[. . . ] Before any cleaning or maintenance operation, disconnect the hood from the mains by removing the plug or disconnecting the home mains switch. Always wear work gloves for all installation and maintenance operations. The appliance is not intended for use by children or persons with impaired physical, sensorial or mental faculties, or if lacking in experience or know-how, unless they are under supervision or have been trained in the use of the appliance by a person responsible for their safety. Children should be monitored to ensure that they do not play with the appliance. [. . . ] Note: 1 bracket can already be fixed to the trellis temporarily with 2 screws during transport. Move it into the desired position or complete fixing it with 6 additional screws, as follows: a. Slightly stretch the brackets to be fixed in order to be able to apply them outside the structure. Position the reinforcement bracket immediately above the fixing point of the two sections of the structure and fix with a total of 8 screws (2 per corner). Fix the second reinforcement bracket, if supplied, in a position midway between the first reinforcement bracket and the upper side of the trellis and fix with 8 screws (2 per corner). Note: check that there is no obstacle to an easy fixing of the discharge tube (aspiration version) or the deflector (filtering version) in positioning the reinforcement bracket(s). Hook the hood to the trellis and make sure that it is perfectly hooked up. Screw the 16 screws up (4 per corner) tightly to hook the hood to the trellis. Apply the perforation diagram of the cooking top to the ceiling vertically (the centre of the diagram must correspond to the centre of the cooking top and the sides must be parallel to the sides of the cooking top ­ the side of the diagram with the word FRONT corresponds to the control panel side). Make holes as indicated (6 holes for 6 wall dowels ­ 4 dowels for hooking), and screw 4 screws into the external holes, leaving a space of about 1 cm between the head of the screws and the ceiling. Hook the trellis to the ceiling with 4 screws, see operation 4). Introduce and screw another 2 screws tightly into the holes for fixing the safety elements remaining free. Introduce a discharge tube inside the trellis and connect to the connecting ring of the motor space (discharge tube and bands not supplied). The discharge tube must be Electrical connection The mains power supply must correspond to the rating indicated on the plate situated inside the hood. If provided with a plug connect the hood to a socket in compliance with current regulations and positioned in an accessible area. If it not fitted with a plug (direct mains connection) or if the plug is not located in an accessible area apply a bi-polar switch in accordance with standards which assures the complete disconnection of the mains under conditions relating to overcurrent category III, in accordance with installation instructions. Before re-connecting the hood circuit to the mains supply and checking the efficient function, always check that the mains cable is correctly assembled. Mounting · · · · · · · · Before beginning installation: Check that the product purchased is of a suitable size for the chosen installation area. To facilitate installation, remove the fat filters and the other parts allowed and described here, dismantle and mount it. To remove see also the relative paragraphs. Remove the active carbon (*) filter/s if supplied (see also relative paragraph). [. . . ] d. ON/OFF light switch Speed 1/OFF switch 2-speed selection 3-speed selection 12 Maintenance ATTENTION!Before performing any maintenance operation, isolate the hood from the electrical supply by switching off at the connector and removing the connector fuse. Eliminate excess water without damaging the filter, then remove the mattress located inside the plastic frame and put it in the oven for 10 minutes at 100° C to dry completely. Replace the mattress every 3 years and when the cloth is damaged. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE SMEG KEIV90

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual SMEG KEIV90 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag