Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual SMEG KFV92DN. We hope that this SMEG KFV92DN user guide will be useful to you.
Lastmanuals help download the user guide SMEG KFV92DN.
Detailed instructions for use are in the User's Guide.
[. . . ] Do not connect the extractor hood to exhaust ducts carrying combustion fumes (boilers, fireplaces, etc. ). If the extractor is used in conjunction with non-electrical appliances (e. g. gas burning appliances), a sufficient degree of aeration must be guaranteed in the room in order to prevent the backflow of exhaust gas. The kitchen must have an opening communicating directly with the open air in order to guarantee the entry of clean air.
USE
The extractor hood has been designed exclusively for domestic use to eliminate kitchen smells. [. . . ] The kitchen must have an opening communicating directly with the open air in order to guarantee the entry of clean air.
USE
The extractor hood has been designed exclusively for domestic use to eliminate kitchen smells. Never use the hood for purposes other than for which it has been designed. Never leave high naked flames under the hood when it is in operation. Adjust the flame intensity to direct it onto the bottom of the pan only, making sure that it does not engulf the sides. Deep fat fryers must be continuously monitored during use: overheated oil can burst into flames. Do not flamb under the range hood; risk of fire This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance.
650 mm min.
MAINTENANCE
Switch off or unplug the appliance from the mains supply before carrying out any maintenance work. Clean and/or replace the Filters after the specified time period (Fire hazard). Clean the hood using a damp cloth and a neutral liquid detergent.
The symbol on the product or on its packaging indicates that this product may not be treated as household waste. Instead it shall be handed over to the applicable collection point for the recycling of electrical and electronic equipment. Fix the pipe in position using sufficient pipe clamps (not supplied). Remove possible charcoal filters.
150
9
120
RECIRCULATION VERSION AIR OUTLET Assemble the two halves of the hood body extension piece 14. Push fit the assembled hood body extension piece 14 onto the air outlet. Push fit connection 15 onto the hood body extension piece 14. Insert the connection extension pieces laterally 14. 1 in connection 15. Make sure that the outlet of the extension pieces 14. 1 is horizontally and vertically aligned with the chimney outlets. If this is not the case, adjust the position by either reversing the connection extension pieces 14. 1 or by cutting the hood body extension 14 along one of the thinner section channels denoting the pre-fixed lengths, then reassemble as described previously. Remove the filters one at a time by pushing them towards the back of the group and pulling down at the same time. Wash the filters, taking care not to bend them. When refitting the filters, make sure that the handle is visible on the outside.
Activated charcoal filter (Recirculation version)
REPLACING THE ACTIVATED CHARCOAL FILTER The filter is not washable and cannot be regenerated, and must be replaced approximately every 4 months of operation, or more frequently for particularly heavy usage. [. . . ] Remove the filters one at a time by pushing them towards the back of the group and pulling down at the same time. Wash the filters, taking care not to bend them. When refitting the filters, make sure that the handle is visible on the outside.
Activated charcoal filter (Recirculation version)
REPLACING THE ACTIVATED CHARCOAL FILTER The filter is not washable and cannot be regenerated, and must be replaced approximately every 4 months of operation, or more frequently for particularly heavy usage. Remove the saturated activated carbon filter by releasing the fixing hooks. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE SMEG KFV92DN
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.
Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual SMEG KFV92DN will begin.