Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual SMEG LD493EB. We hope that this SMEG LD493EB user guide will be useful to you.
Lastmanuals help download the user guide SMEG LD493EB.
Detailed instructions for use are in the User's Guide.
[. . . ] Adjust extension of the hood support structure, as the final height of the hood depends on this, and remember that with installation completed the hood must be at least 50 cm above the cook-top for electric cookers and 75 cm for gas or mixed cookers. Fix the two sections of the structure using 8 screws. If the hood is provided with extensions longer than the minimum, fit the reinforcement bracket S to the frame, using 4 screws. Place the ceiling hole diagram directly above the cook-top (the center of the diagram must match the center of the cook-top and the edges must be parallel to the sides of the cook-top the side of the diagram with the wording FRONT corresponds to the control panel side). [. . . ] Secure the hood to the truss using two screws; this will also help center the two sections. For filter versions (13F), fit deflector F to the truss and secure it to the bracket supplied using 4 screws, then connect the exhaust pipe to the connection ring located on the deflector. Fit the nuts with fixing hooks supplied inside the top and bottom sections of the flues at the rectangular slots. Join the two top sections of the flue to cover the truss so that one of the slots on the sections is situated on the same side of the control panel and the other on the opposite side. Screw the two sections together with 4 screws (2 each side- see the plan diagram for joining the two sections). Fix the top flue assembly to the truss, near the ceiling, with two screws (one each side). Make connections taking care to insert the connectors in the right way. Join the two bottom sections of the flue covering the truss using 6 screws (3 each side, see the plan diagram for joining the two sections). Insert the bottom section of the flue in its seat so that it completely covers the motor compartment and electrical connection box, then ensure it from inside the hood using two screws. Apply the 2 tabs (supplied) to cover the fixing points of the bottom flue (CAUTION! tHE BOTTOM FLUE TABS ARE THE NARROWER AND SHALLOWER ONES). When washed in a dish-washer, the grease filter may discolour slightly, but this does not affect its filtering capacity. To remove the grease filter, pull the spring release handle (f) - (Fig. Only for model with electronic control panel: Once the grease filters have been cleaned, press button 1 (see preceding page) for about 3 seconds until you hear the acoustic signal (beep): the LED 4 will now stop flashing. charcoal filter (filter version only) It absorbs unpleasant odours caused by cooking. The charcoal filter can be washed once every two months (when using the hood 2, 5 hours per day, in avarage and, for the model with electronic control panel, every time LED 5 starts to flash see preceding page) using hot water and a suitable detergent, or in a dish-washer at 65°C (if the dish-washer is used, select the full cycle function and leave dishes out). Eliminate excess water without damaging the filter, then remove the mattress located inside the plastic frame and put it in the oven for 10 minutes at 100° C to dry completely. Replace the mattress every 3 years and when the cloth is damaged. Insert the pad (i) of activated carbon into the frame (h) and fit the whole back into its housing (j). Only for model with electronic control panel: Once you have replaced the charcoal filter, press button 1 (see preceding page) for about 3 seconds until you hear the acoustic signal (beep). Prior to touching the light bulbs ensure they are cooled down. Press on the lamp cover and release to open. [. . . ] Slide out the lightbulb to be replaced and replace with a new 12V 20W 30° Ø35 12V GU4 PHILIPS STANDARD LINE code 425409. If the lights do not work, make sure that the lamps are fitted properly into their housings before you call for technical assistance. caution This appliance is designed to be operated by adults. Children should not be allowed to tamper with the controls or play with the appliance. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE SMEG LD493EB
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.
Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual SMEG LD493EB will begin.