[. . . ] WARNING: - TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP GREASE FIRE, OBSERVE THE FOLLOWING: SMOTHER FLAMES with a close-fitting lid, cookie sheet, or metal tray, then turn off the burner. If the flames do not go out immediately EVACUATE AND CALL THE FIRE DEPARTMENT. NEVER PICK UP A FLAMING PAN - You may be burned. DO NOT USE WATER, including wet
dishcloths or towels - a violent steam explosion will result. [. . . ] DO NOT obstruct the flow of combustion and ventilation air. Failure to follow venting requirements may result in a fire. ELECTRICAL REQUIREMENTS A 120 volt, 60 Hz AC-only electrical supply is required on a separate 15 amp fused circuit. A timedelay fuse or circuit breaker is recommended. The fuse must be sized per local codes in accordance with the electrical rating of this unit as specified on the serial/rating plate located inside the unit near the field wiring compartment. THIS UNIT MUST BE CONNECTED WITH COPPER WIRE ONLY. Wire sizes must conform to the requirements of the National Electrical Code, ANSI/NFPA 70 - latest edition, and all local codes and ordinances. Wire size and connections must conform with the rating of the appliance. Copies of the standard listed above may be obtained from:
National Fire Protection Association Batterymarch Park Quincy, Massachusetts 02269
This appliance should be connected directly to the fused disconnect (or circuit breaker) through flexible, armored or nonmetallic sheathed copper cable. Allow some slack in the cable so the appliance can be moved if servicing is ever necessary. A UL Listed, 1/2" conduit connector must be provided at each end of the power supply cable (at the appliance and at the junction box). · Never use the hood for purposes other than for which it has ben designed. · Never leave high naked flames under the hood when it is in operation. · Adjust the flame intensity to direct it onto the bottom of the pan only, making sure that it does not engulf the sides. · Deep fat fryers must be continuously monitored during use: overheated oil can burst into flames. · The hood should not be used by children or persons not instructed in its correct use.
CARE
· Switch off or unplug the appliance from the main supply before carrying out any maintenance work. · Clean and/or replace the Filters after the specified time period. · Clean the hood using a damp cloth and a neutral liquid detergent. .
THERMAL PROTECTOR
The range hood is equipped with a thermal protector to avoid overheating conditions. If the range hood shuts off in use, press the on/off button to return off range hood. Wait approximately 90 minutes, then press the on/off button to restart the range hood.
EN
6 6
DIMENSIONS and MAIN PARTS
Dimensions
Min. 35" - Max. 38" 1/8
2" 7/16
5" 1/8
21" 1/4 12" 1/2
2" 3/8
19" 5/16
10" 5/8
12"
30" - 36"
Components
Ref. 1 2 2. 1 2. 2 8a 8b 10 14. 1 15 Q. ty Product Components 1 Hood Body, complete with: Controls, Light, Blower, Filters 1 Telescopic Chimney comprising: 1 Upper Section 1 Lower Section 1 Right Air Outlet Grill Aria 1 Left Air Outlet Grill Aria 1 Damper 2 Air Outlet Connection Extension 1 Air Outlet Connection
3" 1/2
15
14. 1 11
12a 7. 2. 1 10
2. 1 2 8b 2. 2
12c 8a
Ref. [. . . ] · Insert the connection extension pieces laterally 14. 1 in connection 15. · Make sure that the outlet of the extension pieces 14. 1 is horizontally and vertically aligned with the chimney outlets. If this is not the case, adjust the position by either reversing the connection extension pieces 14. 1 and then reassemble as described previously. · Ensure that the activated charcoal filters have been inserted.
15
14. 1
EN
9 9
ELECTRICAL CONNECTION · Remove the cover from the Field Wiring Compartment with a phillips screwdriver. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE SMEG MBR35LVM
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.