User manual SMEG PGFA75F

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual SMEG PGFA75F. We hope that this SMEG PGFA75F user guide will be useful to you.

Lastmanuals help download the user guide SMEG PGFA75F.


Mode d'emploi SMEG PGFA75F
Download
Manual abstract: user guide SMEG PGFA75F

Detailed instructions for use are in the User's Guide.

[. . . ] Summary 1 2 3 4 5 6 7 8 INSTRUCTIONS FOR SAFE AND PROPER USE________________ 4 POSITIONING OF THE HOB ________________________________ 6 GAS CONNECTION______________________________________ 12 ADJUSTMENT TO DIFFERENT TYPES OF GAS _______________ 14 FINAL OPERATIONS _____________________________________ 16 USING THE HOB ________________________________________ 17 CLEANING AND MAINTENANCE ___________________________ 19 PROBLEMS AND CAUSES ________________________________ 20 THESE INSTRUCTIONS ARE VALID ONLY FOR END USER COUNTRIES WHOSE IDENTIFICATION SYMBOLS APPEAR ON THE COVER OF THIS MANUAL. INSTRUCTIONS FOR THE INSTALLER: these are for the qualified technician who must carry out a suitable check of the gas system, install the appliance, set it functioning and carry out an inspection test. INSTRUCTIONS FOR THE USER : these contain user advice, description of the commands and the correct procedures for cleaning and maintenance of the appliance. 3 Introduction 1 INSTRUCTIONS FOR SAFE AND PROPER USE THIS MANUAL IS AN INTEGRAL PART OF THE APPLIANCE AND THEREFORE MUST BE KEPT IN ITS ENTIRETY AND IN AN ACCESSIBLE PLACE FOR THE WHOLE WORKING LIFE OF THE HOB. WE ADVISE READING THIS MANUAL AND ALL THE INSTRUCTIONS THEREIN BEFORE USING THE HOB. ALSO KEEP THE SERIES OF NOZZLES SUPPLIED. [. . . ] For definition of hob, see Clause 1. 4. 64. For definition of trivet, see Clause 1. 4. 109. Consideration is to be given to window treatments when located near cooking appliances. See Clause 5. 3. 4. 3 1 2 3 4 5 2. 4 Room ventilation Caution ­ This hob may only be installed and operated in rooms permanently ventilated in accordance with current regulations. For proper operation of a gas appliance it is essential for the air necessary for combustion of the gas to be able to flow naturally into the room. Air must flow directly into the room through openings in its outside walls. This (these) opening (s) must have a free passage cross-section of at least 100 cm2, or 200 cm2 for appliances not equipped with gas safety device. These openings must be constructed so that they cannot be obstructed indoors or outdoors, and should preferably be close to the floor on the side opposite to the combustion gas discharge point. If it is not possible to make the openings in the room where the cooker is installed, the necessary air may be taken from an adjoining room, proveded it is not a bedroom or a room with fire risk. 10 Instructions for the installer Discharge of combustion products Discharge of combustion products must be guaranteed by means of hoods connected to a natural draught flue with certain efficiency, or by means of forced aspiration. An efficient aspiration system requires careful planning by a specialist capable of installing it, respecting the positions and distances prescribed by standards. After installation, the installer must issue a certificate of conformity. 11 Instructions for the installer 3 GAS CONNECTION This appliance is suitable for installation with Natural Gas or LPG (propane). Refer to page 12 for the relevant burner pressure and appropriate injector sizes. When the appliance is to be connected to Natural Gas then the pressure regulator supplied must be fitted to the gas inlet. A test point (for checking the gas pressure) is supplied either with the regulator or as a separate fitting in the case of LPG (propane) appliances. Connection of the appliance to the gas supply must be in accordance with the requirements of AS5601. A ½" BSP connector at the inlet is recommended and the gas supply line to the appliance must be of adequate length to allow sufficient withdrawal of appliance for service or disconnection and be: 1. flexible hose according to AS/NZ1869 & be at least Class "B", 10 mm diameter. The appliance must be installed with provision to allow the gas to be turned off and disconnected for servicing and removal of the appliance as required from the gas supply. Before the appliance is operated make certain all relevant parts are placed in the correct position. When the installation is completed the installation connections of appliance will require to be leak tested, the burner operating pressure and flame checked and adjusted. Warranty service calls do not cover these adjustments!To check the operating pressure of the appliance it is recommended at least 2 large size burners are used. [. . . ] When using fats or oils, be extremely careful that they do not overheat and catch fire. 6. 3 Diameter of receptacles BURNERS Ø min. (cm) 12-16 16-22 20-26 1 2 3 Auxiliary Semi rapid Ultra rapid See below for the diameters of the pans which can be used with the raised pan stand. Ultra rapid 26-34 18 Instructions for the user 7 CLEANING AND MAINTENANCE Before any intervention, disconnect the appliance from the mains. 7. 1 Cleaning the stainless steel To keep stainless steel in good condition it should be cleaned regularly after use. 7. 1. 1 Routine daily cleaning To clean and preserve the stainless steel surfaces, always use only specific products that do not contain abrasives or chlorine-based acids. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE SMEG PGFA75F

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual SMEG PGFA75F will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag