User manual SMEG PU106

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual SMEG PU106. We hope that this SMEG PU106 user guide will be useful to you.

Lastmanuals help download the user guide SMEG PU106.


Mode d'emploi SMEG PU106
Download
Manual abstract: user guide SMEG PU106

Detailed instructions for use are in the User's Guide.

[. . . ] We have provided many important safety messages throughout this manual and on your appliance. Read all instructions before using your appliance and always obey all safety messages. RECOGNIZE SAFETY INFORMATION This is a safety alert symbol. This symbol alerts you to potential hazards that can kill or hurt you and others. UNDERSTAND SIGNAL WORDS A signal word ­ DANGER, WARNING, or CAUTION ­ is used with the safety-alert symbol. [. . . ] Proper gas supply connection must be available. See "Gas Supply Requirements" section - - - To prevent accidents or ruining the mobile components of the appliance, the following steps must be taken before performing the procedures described below: 1 Remove all packaging parts (e. g. crate, carton, polystyrene and metal hooks). Do not eliminate this manual as it is an integral part of the appliance and it should be kept handy for easy reference whenever needed. 2 Temporarily remove all removable parts from the cooktop that could fall and cause personal injury or damage to objects (burners, crowns and flame caps) during the attachment procedures These parts must be refitted before using the appliance. The measurements supplied in the tables referring to the figure below must be followed when attaching the appliance to the support structure. 6 Instructions for the Installer Cooktop widht 23 /8" 600 mm 27 1/2" 700 mm 39 3/8" 1000 mm 5 1 MINIMUM DISTANCE A 22 /4" - 22 /8" 565 - 569 mm 22 1/4" - 22 3/8" 565 - 569 mm 33 11/16" - 33 14/16" 855 - 860 mm 3 B 19"- 19 /8" 483 - 485 mm 19"- 19 1/8" 483 - 485 mm 19 1/8" - 19 5/16" 485 - 490 mm 1 C 8 / 4" 210 mm 8 1/ 4" 210 mm 8 1/ 4" 210 mm 1 D 3 /8" 86 mm 3 3/8" 86 mm 4 7/16" 112 mm 3 E 1 /16" 36 mm 1 7/16" 36 mm 1 7/16" 36 mm 7 F 1 /4" 45 mm 1 3/4" 45 mm 1 3/4" 45 mm 3 G 23 5/8" 600 mm 27 1/2" 700 mm 39 3/8" 1000 mm Gas line opening Wall: everywhere, 5" (12. 7 cm) below underside of countertop. Cabinet base: everywhere, within 6" (15. 2 cm) from rear wall is recommended. Grounded outlet Locate within 24" (61 cm) from the right rear corner of the cut out drawer. 7 Instructions for the Installer 3. 1 Gas supply requirements EXPLOSION HAZARD Use a new AGA- or CSA-approved gas supply line. lf connected to LP, have a qualified technician ensure that gas pressure does not exceed a 14" water column. Examples of qualified technicians include licensed heating personnel, authorized gas company personnel, and authorized service personnel. Failure to do so can result in death, explosion, or fire. WARNING - - - NOTE: - observe all government codes and ordinances. - The cooktop must be connected to a regular gas supply. 1) This installation must conform to local codes and ordinances. In the absence of local codes, installations must conform to American National Standards, National Fuel Gas Code ANSI Z223. 1 - latest edition** or CANI 13149. 1 or 2**. If local codes permit, a flexible metal appliance connector with the new AGA- or CSAcertified design, 4-5 feet (1. 2-1. 5 m) long, 1/2" or 3/4" I. D. , is recommended for connecting this cooktop to the gas supply line. Do not bend or damage the flexible connector when moving the cooktop. The pressure regulator has 3/8 female pipe threads. You will need to determine the fittings required, depending on the size of your gas supply line, the flexible metal connector and the shut-off valve. The supply line shall be equipped with an approved shut-off valve. This valve should be located in the same room as the cooktop and should be in a location that allows for easy opening and closing. Do not block access to the shut-off valve. The valve is necessary for turning the gas to the appliance on or off. 2) 3) 8 Instructions for the Installer The regulator must be checked at a minimum water column of at least 1" (2. 5 cm) above the set pressure. The inlet pressure to the regulator should be as follows for operation and monitoring of the regulator setting: - NATURAL GAS: Set pressure at 6" (15. 2 cm). [. . . ] Check that the shut-off valve is in the "ON" position. lf a burner does not light at this point, contact your dealer for assistance. 14 Instructions for the Installer 6. WIRING DIAGRAMS The power cord on this appliance is equipped with a threee pronge polarized plug (grounding) which mates with standard three pronged (grounding) wall receptacles. WARNING Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE SMEG PU106

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual SMEG PU106 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag