User manual SMEG S341AS

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual SMEG S341AS. We hope that this SMEG S341AS user guide will be useful to you.

Lastmanuals help download the user guide SMEG S341AS.


Mode d'emploi SMEG S341AS
Download
Manual abstract: user guide SMEG S341AS

Detailed instructions for use are in the User's Guide.

[. . . ] INSTRUCTIONS FOR THE USER: these contain user advice, description of the commands and the correct procedures for cleaning and maintenance of the appliance. INSTRUCTIONS FOR SAFE AND PROPER USE THIS MANUAL IS AN INTEGRAL PART OF THE APPLIANCE AND THEREFORE MUST BE KEPT IN ITS ENTIRETY AND IN AN ACCESSIBLE PLACE FOR THE WHOLE WORKING LIFE OF THE COOKING HOB. WE ADVISE READING THIS MANUAL AND ALL THE INSTRUCTIONS THEREIN BEFORE USING THE COOKING HOB. ALSO KEEP THE SERIES OF NOZZLES SUPPLIED. [. . . ] However, in no case shall the clearance between the highest part of the hob of the cooking appliance and a range hood be less than 600 mm or, for an overhead exhaust fan, 750 mm. Any other downward facing combustible surface less than 600 mm above the highest part of the hob shall be protected for the full width and depth of the cooking surface area in accordance with Clause 5. 12. 1. 2. However, in no case shall this clearance to any surface be less than 450 mm. 9 Instructions for the installer 2 Side clearances ­ (Measurements B & C) Where B, measured from the periphery of the nearest burner to any vertical combustible surface, is less than 200 mm, the surface shall be protected in accordance with Clause 5. 12. 1. 2 to a height C of not less than 150 mm above the hob for the full dimension (width or depth) of the cooking surface area. Where the cooking appliance is fitted with a `splashback', protection of the rear wall is not required. Additional requirements for Freestanding and Elevated Cooking Appliaces ­ (Measurements D & E) Where D, the distance from the periphery of the nearest burner to a horizontal combustible surface is less than 200 mm, then E shall be 10 mm or more, or the horizontal surface shall be above the trivet. NOTES 1 Requirement 3 does not apply to a freestanding or elevated cooking appliance which is designed to prevent flames or the cooking vessels from extending beyond the periphery of the appliance. The `cooking surface area' is defined as that part of the appliance where cooking normally takes place and does not include those parts of the appliance containing control knobs. For definition of hob, see Clause 1. 4. 64. For definition of trivet, see Clause 1. 4. 109. Consideration is to be given to window treatments when located near cooking appliances. See Clause 5. 3. 4. 3 2 3 4 5 2. 4 Room ventilation Caution ­ This hob may only be installed and operated in rooms permanently ventilated in accordance with current regulations. regulator must be checked and adjusted to 1. 0kPa after installation. ULPG: Can be connected to the inlet fitting directly. The pressure must be checked to ensure it is operating at 2. 75kPa. A separate test point fitting must be installed between the piping & the appliance for the pressure to be checked to ensure it is operating at 2. 75kPa. 12 Instructions for the installer 3. 1 Electrical connection Make sure that the voltage and capacity of the power line conform to the data shown on the plate located under the casing. Do not remove this plate for any reason. The plug on the end of the supply cable and the wall socket must be the same type and conform to the current electrical system regulations. Check that the power line is adequately grounded. On the power line, install an omnipolar cut-off device with contact cut-off distance greater than or equal to 3 mm, located in an easily accessible position near the unit. Do not use reducers, adapters or shunts. If the power cable is replaced, the wire section on the new cable must not be less than 0. 75 mm2 (3 x 0. 75 cable), keeping in mind that the end to be connected to the hob must have the ground wire (yellow-green) longer by at least 20 mm. Use only H05V2V2-F cable or similar which has a maximum temperature of 90°C. Any replacement needed should be carried out by a specialised technician who should make the mains connections according to the following diagram. [. . . ] To avoid burns or damage to the hob, all recipients or griddle plates must be placed within the perimeter of the cooking hob. When using fats or oils, be extremely careful that they don't overheat and catch fire. 6. 3 Diameter of containers BURNERS Ø min. (in cm) 12-14 16-20 20-26 1 2 4 Auxiliary Semi rapid WOK See below for the diameters of the pans which can be used with the raised pan stand. Ultra rapid 26-34 18 Instructions for the user 7. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE SMEG S341AS

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual SMEG S341AS will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag