User manual SMEG S841AE

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual SMEG S841AE. We hope that this SMEG S841AE user guide will be useful to you.

Lastmanuals help download the user guide SMEG S841AE.


Mode d'emploi SMEG S841AE
Download
Manual abstract: user guide SMEG S841AE

Detailed instructions for use are in the User's Guide.

[. . . ] IMMEDIATELY AFTER INSTALLATION, CARRY OUT A BRIEF INSPECTION TEST OF THE APPLIANCE, FOLLOWING THE INSTRUCTIONS BELOW. SHOULD THE APPLIANCE NOT FUNCTION, DISCONNECT IT FROM THE POWER SUPPLY AND CONTACT YOUR NEAREST TECHNICAL ASSISTANCE CENTRE. NEVER ATTEMPT TO REPAIR THE APPLIANCE YOURSELF. ALWAYS CHECK THAT THE CONTROL KNOBS ARE IN THE POSITION (OFF) WHEN YOU FINISH USING THE HOB. 20 Introduction THE APPLIANCE DATA PLATE, WITH TECHNICAL DATA, REGISTRATION NUMBER AND BRAND NAME, IS POSITIONED AT A VISIBLE POINT UNDER THE SAFETY COVER. [. . . ] Having done this, place the hob on top of the gasket and using the screws and fixing brackets "C" or "D" (depending on the depth of the worktop ­ Fig. 4) secure the hob to the support structure, ensuring it is level. The brackets "C" secure the hob to a structure having a depth of 20 to 30 mm. The brackets "D" on the other hand, are for use with worktops having a depth of 30 to 50 mm. Carefully trim any excess from edge C (Fig. 3) of the gasket. The distances in figure 2 refer to the hole on the inner side of the gasket. 22 Instructions for the installer 2) 3) 4) 23 Instructions for the installer 2. 2 Attachment to support structure, flush-mounting model Create an opening with the dimensions shown in the figure in the work surface, observing a minimum distance of 50 mm from the rear edge. The lower part of the protective cover must be fully accessible when the appliance is installed. This appliance can be installed next to walls that are higher than the work surface, as long as the distance "X" is kept, as shown in the 1) figure, to avoid damage from overheating. Make sure there is a minimum of 750 mm (Fig. 1) between the gas rings and any shelf that may be installed directly above them. This type of appliance requires the worktop, the dimensions of which are shown shown in figure 2, to be milled to a depth of 2. 5 mm. Before positioning the hob, position the adhesive sponge material "E" supplied over the milled surface (fig. For use with other types of gas, see chapter "3. The hose connection at the rear of the appliance has a ½" internal thread (ISO 228-1). Connection with rigid copper pipe: the connection to the gas mains must not provoke stress of any kind on the appliance. Connection may be made by using biconicaladapter D with insertion of gasket C supplied. Connection with flexible steel pipe: use only flexible stainless steel pipes conforming to UNI-CIG 9891 regulations, inserting gasket C supplied between the fitting A and the flexible pipe B. The flexible pipe must be installed so that pipe length does not exceed 2 meters of maximum extension. Make sure that the pipes do not touch any moving parts or become crushed. 2. 7 Connection to LPG Use a pressure regulator and make the connection to the tank according to the provisions of UNI-CIG 7432 and UNI-CIG 7131. Make sure that feed pressure conforms to the levels shown in the table in paragraph "3. 2 Burner and nozzle characteristics table 28 Instructions for the installer 3 ADJUSTMENT TO DIFFERENT TYPES OF GAS Before performing any cleaning or maintenance work, unplug the appliance from the mains. The hob is set for natural gas G20 (2H) at a pressure of 20 mbar. In the case of functioning with other types of gas the burner nozzles must be changed and the minimum flame adjusted on the gas taps. To change the nozzles, proceed as described below. 3. 1 1. [. . . ] This operation must be done by an authorised person. 31 Instructions for the user 5 5. 1 USING THE HOB Ignition of the burners Before turning on the burners, make sure that the flame-spreader crowns and respective caps are properly fitted in their housings. Ensure the flame-spreader holes A are aligned with the ignition plugs and the thermocouples. Panstand grid B, available upon request, is intended for use with woks (Chinese pans). To prevent damage to the worktop, the hob is equipped with a raised grid C to position below cooking receptacles that exceed 26 cm in diameter when used on the side burners. A symbol next to each knob indicates the relative burner. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE SMEG S841AE

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual SMEG S841AE will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag