[. . . ] ISTRUZIONI D'USO MANUTENZIONE E INSTALLAZIONE OPERATING, MAINTENANCE AND INSTALLATION INSTRUCTIONS INSTRUCTIONS POUR L'UTILISATION, LA MAINTENANCE ET L'INSTALLATION BEDIENUNGS-, WARTUNGS- UND INSTALLATIONSANLEITUNGEN INSTRUCCIONES PARA EL USO, MANUTENCION E INSTALLACION INSTRUO E INSTALAO
MOD. 960GG/GE SE990XKG
The symbol on the product or on its packaging indicates that this product may not be treated as household waste. Instead it shall be handed over to the applicable collection point for the recycling of electrical and electronic equipment. By ensuring this product is disposed of correctly, you will help prevent potential negative consequences for the environment and human health, which could otherwise be caused by inappropriate waste handling of this product. [. . . ] A in mind that: standardised plug must be used bearing - yellow - green = earth - blue = neutral - brown = phase
Fig. 4
mains, ensure that: Before connecting the appliance to the
ELECTRICAL CONNECTION
The power supply cable must be positioned so that it does not at any point exceed the ambient temperature by 50C.
The voltage corresponds to the voltage specified on the rating plate at the bottom of the surround. The overload cut-off device and the domestic system can withstand the load of the appliance (see rating plate). The power supply system is provided with an efficient earth connection and that the socket or omnipolar switch, with minimum contact opening of 3mm. , is easily accessible once the appliance has been installed. If the plug is not easily accessible, the installation personnel must provide an omnipolar switch with contact opening distance equal to or greater than 3 mm.
30
Note:
Model 1= . . . B. . . . . . - . . . H. . . . . . - . . . L. . . . . . - . . . Q. . . . . . Model 2= . . . A. . . . . . - . . . D. . . . . . - . . . G. . . . . . - . . . N. . . . . . The actual rated capacity of the G110 gas-operated appliance is 3. 4 kg both for the oven burner and the gas grill.
TECHNICAL SPECIFICATIONS (TABLE 2) Energy consumption g/h Injector for gas G30/G31 (Liquid Gas LPG) mm Injector for gas G20 (Natural Gas) mm Injector for gas G110 (Mains Gas) mm By-pass for gas G30/G31 mm By-pass for gas G20/25 mm Rated capacity kW Minimum capacity kW Rated consumption G30 Kg/h Rated consumption G20 m/h Rated consumption G110 m/h Regulation of air "X" G30/G31 mm Regulation of air "X" G20/G25 mm Regulation of air "X" G110 mm Supply pressure G20 mbar Supply pressure G30/31 mbar Supply pressure G110 mbar Power electric grill kW Min. air exchange necessary for combustion:8 m/h * Factory-set
Model 1 290 OVEN 0, 95 1, 45 3, 00 0, 52 *reg 4 0, 95 290 0, 36 0, 80 open 2 2 20 28/37 8 2, 550
Model 2 290 GRILL 0, 95 1, 45 3, 00 4 290 0, 36 0, 80 open open open
31
CHANGING THE OVEN BURNER INJECTOR (fig. 5)
Ensure that the oven is electrically disconnected; fully open the oven door; take the bedplate out (fig. 5); slide the burner out as follows:
1. 4.
take the diffuser element C out, removing the nuts D; move the plug holder bracket E plus thermocouple; remove the screw B and slide out the burner tube; remove the injector F with a 7 mm spanner and replace it following the instructions in table 2 (the injector must be locked to prevent it sliding out).
refit the oven burner performing the above oprations in reverse order; replace the bedplate.
Pay particular attention to the plug wires and thermocouple tubes.
Fig. 5
32
CHANGING THE GRILL BURNER INJECTOR (fig. 6)
Ensure that the oven is electrically disconnected; fully open the oven door; slide out the grill burner at the top of the oven as follows:
1. 4.
release the ignition plug and the thermocouple bulb from the grill burner; remove the grill burner fastening screw and slide it to the right; remove the injector D with a 7 mm spanner and replace it following the instructions in table 2 (the injector must be locked to prevent it sliding out); refit the burner following the above operations in reverse order.
Pay particular attention to the plug wires and thermocouple tubes.
33
Fig. 7)
Due to the characteristics of the different types of gas used, the flame may have too little or too much air. In this case adjustment must be performed as follows:
Loosen the screw C on the burner (to remove the burner follow the instructions on p. 10-11); turn the ring nut D to position N for methane or natural gas and to position G for liquid gas so that the moving reference mark on the ring nut coincides with the fixed reference mark on the burner, thus obtaining a regular flame (fig. 8).
Examples:
a)Flame with too much air, small and thin: turn the ring nut D to reduce the distance X (anticlockwise).
b)Flame with too litle air, irregular with yellow tips: turn the ring nut D to increase the distance X
Fig. 7 eccesso d'aria / too much air / exces d'air zuviel Luft / exceso de aire fiamma regolare / regular flame / flamme rgulire / regulre Flamme / llama regular mancanza d'aria / not enough air / manque Fig. 8 d'air / zuwenig Luft / falta de aire 34
ADJUSTING THE THERMOSTAT MINIMUM SETTING
This operation is performed with the oven in the unit and after the electrical and gas connections have been made by qualified personnel. The operation is necessary when switching from G20 to liquid gas G30) in order to guarantee a one type of gas to another (from natural gas minimum temperature of around 150C. [. . . ] Place the collecting plate on the lowest shelf. Switch the grill on (knob C, position 2, p. 22
41
MAINTENANCE Damaged parts must be replaced by the Technical Support service. You are also advised to have the appliance serviced by the Technical Support department approximately once a year. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE SMEG SE990XKG
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.