Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual SMEG SIM580B,MV. We hope that this SMEG SIM580B,MV user guide will be useful to you.
Lastmanuals help download the user guide SMEG SIM580B,MV.
Detailed instructions for use are in the User's Guide.
[. . . ] Tuttavia, le varianti specifiche di un determinato paese e il tipo di allacciamento alla rete hanno un'importanza fondamentale per il suo sicuro e corretto funzionamento. Per questo se si vuole usare l'apparecchio in un paese diverso rivolgersi al servizio di assistenza tecnica Miele del paese in cui si intende usarlo. M Het apparaat is ook toegelaten voor gebruik in andere landen dan de landen die op het apparaat vermeld staan. De specifieke uitvoering en de aansluitwijze zijn van groot belang voor het goed en veilig functioneren. [. . . ] This equipment is not designed for maritime use or for use in mobile installations such as caravans, aircraft etc. However it may be suitable for such usage, subject to a risk assessment of the installation being carried out by a suitably qualified engineer.
recommended
not recommended
Due to the heat radiated by the hob and to allow cooking fumes to dissipate, it is essential that a minimum safety distance a of 100 mm is maintained between the worktop cut-out and adjacent furniture, e. g. a tall unit.
not allowed
5
Safety instructions
The room in which the gas hob is installed must be at least 20 m3 in size with a door or window in it which can be opened to the outside air. Using the gas hob will cause a build-up of heat and moisture in the room in which it is installed. Ensure that the room has sufficient natural or mechanical means of ventilation, e. g. If the hob is used for very long periods of time additional ventilation of the room may be necessary, e. g. by opening windows or doors, or running the extractor on the highest setting. The hob may be installed above a Miele oven, if the work-top is at least 40 mm thick. An electric fryer must not be installed next to a gas hob, as the gas flames could ignite the fat in the fryer. It is essential to maintain a distance of at least 300 mm between these two appliances. This gas hob must not be installed over a dishwasher, washing machine, tumble dryer, refrigerator or freezer. The voltage and connected load are given on the data plate. Ensure that these match the household mains supply. Connection should be made via a suitable isolator or a double pole fused spur connection unit which complies with national and local safety regulations and the on/off switch should be easily accessible after the appliance has been built in. If the switch is not accessible after installation (depending on country) an additional means of disconnection must be provided for all poles. For extra safety it is advisable to install a residual current device (RCD) with a trip current of 30 mA. When switched off there must be an all-pole contact gap of 3 mm in the isolator switch (including switch, fuses and relays). This appliance is supplied for connection to a single phase 230-240 V 50 Hz supply with a 3-core cable. The wires in the mains lead are coloured in accordance with the following code: Green/yellow = earth Blue Brown = neutral = live
WARNING THIS APPLIANCE MUST BE EARTHED
13
Electrical connection
Important The electrical safety of this appliance can only be guaranteed when continuity is complete between the appliance and an effective earthing system, which complies with local and national regulations. It is most important that this basic safety requirement is tested regularly and if there is any doubt the electrical wiring in the home should be tested by a qualified electrician. The manufacturer cannot be held liable for the consequences of an inadequate earthing system such as an electric shock. The manufacturer cannot be held liable for damage which is the direct or indirect result of incorrect installation or connection. 3
14
Gas Connection
Connection Connection to the gas supply, or conversion from one type of gas to another should only be undertaken by an approved and registered gas installer in strict accordance with local and national safety and building regulations, (e. g. [. . . ] ^ Remove the operating controls by pulling them upwards. To remove a stainless steel upper section: Lift it up at the back, push it forwards and remove. To remove a ceramic upper section: Insert the lever supplied between the frame and the worktop, prise up the upper section and remove.
a
b
^ Remove the ignitor a. ^ Using a small screwdriver, unscrew the small jet b in the gas fitting. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE SMEG SIM580B,MV
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.
Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual SMEG SIM580B,MV will begin.