User manual SMEG SNL90MFX6

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual SMEG SNL90MFX6. We hope that this SMEG SNL90MFX6 user guide will be useful to you.

Lastmanuals help download the user guide SMEG SNL90MFX6.


Mode d'emploi SMEG SNL90MFX6
Download
Manual abstract: user guide SMEG SNL90MFX6

Detailed instructions for use are in the User's Guide.

[. . . ] THE PLATE ON THE CASING MUST NOT BE REMOVED. BEFORE CONNECTING THE DEVICE, MAKE SURE THAT IT HAS BEEN REGULATED FOR THE TYPE OF GAS THAT WILL FEED IT, CHECKING THE LABEL UNDER THE CASING. DO NOT PUT PANS WITHOUT PERFECTLY SMOOTH AND FLAT BOTTOMS ON THE COOKING HOB GRIDS. DO NOT USE RECIPIENTS OR GRIDDLE PLATES THAT EXTEND BEYOND THE EXTERNAL PERIMETER OF THE HOB. THE HOB IS TO BE USED BY ADULTS ONLY. DO NOT LET UNSUPERVISED CHILDREN PLAY WITH THE HOB. REPLACED APPLIANCES MUST BE TAKEN TO A SPECIAL GARBAGE COLLECTION CENTRE. The manufacturer declines all responsibility for damage to persons or things caused by non-observance of the above prescriptions or by interference with any part of the appliance or by the use of non-original spares. 22 Instructions for the installer 2. POSITIONING OF HOB The following operation requires building and/or carpentry work so must be carried out by a competent tradesman. [. . . ] The panel has to be easily removable to allow access in the event of technical service. 24 Instructions for the installer 3. ELECTRICAL CONNECTION Make sure that the voltage and capacity of the power line conform to the data shown on the plate located under the casing. Do not remove this plate for any reason. The plug on the end of the supply cable and the wall socket must be the same type and conform to the current electrical system regulations. Check that the power line is adequately grounded. On the power line, install an omnipolar cut-off device with contact cut-off distance greater than or equal to 3 mm, located in an easily accessible position near the unit. Do not use reducers, adapters or shunts. If the power cable is replaced, the wire section on the new cable must not be less than 1. 5 mm2 (3 x 1. 5 cable), keeping in mind that the end to be connected to the hob must have the ground wire (yellow-green) longer by at least 20 mm. Use only H05V2V2-F cable or similar which has a maximum temperature of 90°C. Any replacement needed should be carried out by a specialised technician who should make the mains connections according to the following diagram. L = brown N = blue = yellow-green The manufacturer will not be liable for any damage to persons or property caused by non-observance of the above instructions or deriving from the tampering of even a single part of the hob. 25 Instructions for the installer 4. GAS CONNECTION Connection to the gas mains may be made with a rigid copper pipe or with a flexible pipe and conforming to the provisions defined by standard regulations in force. Move the Venturi tube D to regulate the air flow until distance "X" is reached indicated in the chart in paragraph "5. 4 Regulation of primary air" and then secure the tube by means of screw A. After the regulations have been carried out, restore the seals with sealing wax or equivalent material. Burner Rated heating capacity (kW) Nozzle diameter 1/100 mm 48 62 85 48 92 LPG ­ G30/G31 30/30 mbar Auxiliary (1) Semi-rapid (2) Rapid (3) Double crown internal (4) external (4) 1. 05 1. 65 3. 1 1. 15 3. 8 By-pass mm 1/100 30 33 (*) 30 33 (*) 43 45 (*) 30 33 (*) 55 Reduced flowrate (W) 380 380 750 380 1200 Flowrate g/h G30 76 120 224 76 282 (*) By-pass value for valveless appliances. 29 Instructions for the installer 5. 3 Regulation for G25/25 mbar The hob has been inspected for G25 (2L) at a pressure of 25 mbar. To allow the unit to work with this type of gas, perform the same operations described in paragraph "5. 2 Regulation for LPG", but choose the nozzles and regulate the primary air for natural gas, as shown in the following table and in paragraph "5. 4 Regulation of primary air". After the regulations have been carried out, restore the seals with sealing wax or equivalent material. Burner Rated heating capacity (kW) G25 25 mbar Nozzle diameter 1/100 mm Reduced flowrate (W) Auxiliary (1) Semi-rapid (2) Rapid (3) Double crown internal (4) internal (4) 1. 05 1. 65 3. 1 1. 05 3. 9 76 98 130 76 150 380 380 750 380 1200 5. 4 Regulation of primary air G30/G31 30/30 mbar 2. 0 2. 0 9. 0 6. 0 10. 0 Referred to distance "X" in mm. G25 25 mbar Auxiliary (1) 1. 5 Semi-rapid (2) 1. 5 Rapid (3) 2. 0 internal (4) 3. 0 Double crown external (4) 3. 0 (*) For burner reference numbers, see page 32. BURNER 30 Instructions for the installer 6. FINAL OPERATIONS Having carried out the above adjustments, reassemble the appliance following, backwards, the instructions in paragraph "5. 1 Removing the hob". 6. 1 Regulation of minimum for natural gas Replace the components on the burner and slide the knobs on the gas tap pins. Light the burner and set it at minimum position. Remove the knob and turn the regulation screw inside or next to the gas tap pin (depending on the model) until you get a suitable minimum flame. Replace the knob and check burner flame stability: (rapidly turning the knob from maximum to minimum position, the flame should not go out). 6. 2 Regulation of minimum for LPG To regulate the minimum for LPG, completely tighten (clockwise) the screw inside or next to the gas tap pin (depending on the model). The diameters of the by-passes for each burner are given in table "5. 2 Regulation for LPG". After having regulated the device with gas other than the one tested, replace the label located on the guard with the one that corresponds to the new gas. The label is inside the bag that contains the nozzles provided. 31 Instructions for the installer 6. 3 Arrangement of burners on hob BURNERS 1 2 3 4 Auxiliary Semi-rapid Rapid Double crown 6. 4 Lubrication of gas taps After a while, the gas tap may become hard to turn or lock. [. . . ] How to use: pour the product on a damp cloth and wipe the surface, rinse thoroughly and dry with a soft cloth or deerskin. 8. 1. 2 Food stains or residues Do not use metallic sponges or sharp scrapers: they will damage the surface. Use normal non-abrasive products and remove spots or residuals with non-scratch sponges or, if need be, with wood or plastic utensils. Rinse thoroughly and dry with a soft cloth or deerskin. 8. 2 Cleaning of cooking hob components Grids, caps, flame cap crowns and burners can be removed for ease of cleaning. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE SMEG SNL90MFX6

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual SMEG SNL90MFX6 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag