[. . . ] 13 5. 4 Modifiable parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 5. 5 Alarm trigger time thresholds . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 5. 6 Adjusting detergent and rinse aid dispensing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 6 MALFUNCTIONS SHOWN ON THE DISPLAY (FOR THE TECHNICIAN) . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] The total rated power is stated on the appliance's technical data plate. The electrical protection devices fitted for the dishwasher must serve this appliance only. The user must have a master switch and a differential safety breaker, with rating suitable for the appliance's characteristics, installed on the electricity supply line in accordance with the relevant regulations. These switches must be installed close to the dishwasher, be easily accessible after installation, and provide complete disconnection from the electrical mains in
9
overvoltage class III conditions. The dishwasher is always powered up unless the master switch is turned off. Connect the appliance to the user's earth system. The terminal for the connection is in the bottom righthand corner of the appliance. The earth wire (PE) is yellowgreen in colour, the neutral wire (N) is blue and the live wires (L1, L2, L3) are black, grey and brown. THE POWER SUPPLY CABLE MUST BE REPLACED BY THE MANUFACTURER OR AN AUTHORISED SERVICE CENTRE TO PREVENT ALL RISKS.
Key to threephase electrical system diagram
Boiler temperature probe Tank temperature probe Detergent sensor Rinse aid sensor Filter sensor Flowmeter Salt sensor Door sensor Rinsing pump Washing pump Boiler level pressure switch Boiler safety thermostat Terminal board RFI filter Mains fuse Boiler contactor Boiler heating element Overtemperature fuse Tank safety thermostat Tank heating element EVA EVR EVS PB PD EVF PS PLA PLV PSV AQS SB SI TM TV TF TPL TPR TRV TB Aquastop solenoid valve Regeneration solenoid valve Brine discharge solenoid valve Rinse aid peristaltic pump Detergent peristaltic pump Filler solenoid valve Drain pump Analog level pressure switch Tank level pressure switch Tank safety pressure switch Aquastop microswitch Motherboard Interface board Terminal board ground Tank ground RFI filter ground Washing pump ground Rinsing pump ground Tank heating element ground Boiler heating element ground
NTCB NTCV SDET SBRIL SFIL FLMT SS RD PR PL PLB THB M LF FUSE CB RB TFU THRV RV
10
CWC 610
Figure 1 Appliance threephase electrical system diagram
11
First startup
CWC 610
The electrical protection system must undergo a functional test before the appliance is put into operation. The appliance must be installed and/or inspected by qualified staff, who will start it up for the first time and provide the relevant operating instructions. Do not mix different detergents; this would damage the dispenser device. Failure to comply with this recommendation leads to forfeiture of the warranty entitlement on the appliance's water system. Industrial dishwasher detergents may cause serious irritation. Comply carefully with the instructions provided by the detergent producer on the pack. Turn on the mains water tap (user) CHECK 2. The level of detergent and rinse aid in the containers. That the filters are in place, the spray arms rotate. Switch on the master switch (user): the word "OFF" appears on the display.
7. 3 First use each day (tank and boiler empty)
Display shows
Actions and what happens
Door closed and master switch on ON: Press and hold it down for 23 seconds; the ON/OFF light and the two digits on the display light up. The dishwasher fills the tank automatically. At the end of this phase, when the tank is full, P appears on the display and program lights L5, L6 and L7are lit. [. . . ] Remove spray arms and clean them (8. 2 Periodic checks) See "Cleaning the filter during the day" Check type and quantity of detergent. Check that the intake filter is not fouled. If you are unable to solve the problem, call the aftersales service. Check temperature shown on the display, call the aftersales service if less than 50°C Increase wash cycle duration, especially if dirt has dried on. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE SMEG UK60MFA
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.