[. . . ] S-BUS INTERFACE BOARD
BKP-7933
INSTALLATION MANUAL 1st Edition (Revised 1)
!WARNING
This manual is intended for qualified service personnel only. To reduce the risk of electric shock, fire or injury, do not perform any servicing other than that contained in the operating instructions unless you are qualified to do so. Refer all servicing to qualified service personnel.
! [. . . ] Setting Up
Connecting Peripheral Equipment
REMOTE RCP/CNU
CCA-5 CABLE
CCU 1 to 6
CNU-700 with BKP-7933
MSU
CCA-5 CABLE
REMOTE CCU/CNU
RCP 1 to 6 REMOTE S-BUS
CCU-700A with BKP-7311
SERIAL * OUTPUT
CHARACTER
CCA-5 CABLE MSU-700
REMOTE RCP/CNU SERIAL * OUTPUT REMOTE RCP/CNU
PIX
REMOTE
CCU-700A with BKP-7311
REMOTE CONTROL UNIT BKS-R3202
REMOTE 1 IN 1 IN 2 IN 6 OUT 1 OUT 2 OUT 6
PIX
WF
REMOTE CCU/CNU
CCU-550 with BKP-5972
SERIAL * OUTPUT
REMOTE 3
DIGITAL ROUTING SWITCHER DVS-V1616
PIX RS-232C S-BUS BNC (BELDEN 8281) VIDEO BNC PIX
WF
REMOTE CCU/CNU
WF
SDI MONITOR for RCP CONTROL TERMINAL (IBM PC/AT COMPATIBLES) * If using the ANALOG ROUTING SWITCHER (BVS-V3232 etc. ), connect it to PIX, WF or VBS connector
REMOTE CCU/CNU
RCP-700 Series
BKP-7933
1-23 (E)
1-7. Setting Up
Setting from the S-BUS Primary Station 1. Select the menu item "B:SET UNIT LOCATION (CCU-RCP)" and press [ENTER]. Move the cursor key to the desired position to be changed and press [ENTER]. (The display enters the input mode. )
SONY ROUTING SYSTEM SETUP MENU
BKP-7933 V1. 00
STATION NUMBER 2
MODIFICATION COMMAND A: SET UNIT LOCATION(CAM-CCU) C: SET UNIT LOCATION(MSU) K: RESET TO DEFAULT TABLE B: SET UNIT LOCATION(CCU-RCP)
MAINTENANCE COMMAND Z: BKP-7933 CONFIGURATION
Ctrl-D RETURN
3. using the numeric keys and press [ENTER]. Up to 96 in the range of 1 to 1024 can be selected and set to the SOURCE No. and DESTINATION No. , but the numbers must be consecutive. Any number in the range of 1 to 8 can be set to the LEVEL No. This setting can be assigned to the respective level and can be mapped.
SET UNIT LOCATION(CCU-RCP)
BKP-7933 V1. 00
STATION NUMBER 2
CCU-RCP MATRIX(Remote RCP ASSIGNMENT) SOURCE No DESTINATION No 0045 -0056 0045-0056
LEVEL No 1
Ctrl-E RETURN TO MENU
1-24 (E)
BKP-7933
1-7. Switching the MSU Camera Selection Externally
Description of Operation Set the menu as follows when you want to switch the MSU camera selection from a remote location. When this setting is executed, each one of up to 16 MSUs can be specified to control a certain camera. Connecting Peripheral Equipment
REMOTE RCP/CNU
CCA-5 CABLE
CCU 1 to 6
CNU-700 with BKP-7933
MSU
CCA-5 CABLE
REMOTE CCU/CNU
CCU-700A with BKP-7311
SERIAL * OUTPUT
CHARACTER
REMOTE S-BUS
MSU-700
REMOTE RCP/CNU
PIX
REMOTE
PIX REMOTE CONTROL UNIT BKS-R3202
WF
CCU-700A with BKP-7311
SERIAL * OUTPUT REMOTE RCP/CNU REMOTE 1 IN 1 IN 2
SDI MONITOR for MSU camera select
CCU-550 with BKP-5972
SERIAL * OUTPUT
OUT 13 IN 6 REMOTE 3
DIGITAL ROUTING SWITCHER DVS-V1616
RS-232C S-BUS BNC (BELDEN 8281) VIDEO BNC
CONTROL TERMINAL (IBM PC/AT COMPATIBLES) * If using the ANALOG ROUTING SWITCHER (BVS-V3232 etc. ), connect it to PIX, WF or VBS connector
BKP-7933
1-25 (E)
1-7. Setting Up
Setting from the S-BUS Primary Station 1. Select the menu item "C:SET UNIT LOCATION (MSU)" and press [ENTER].
SONY ROUTING SYSTEM SETUP MENU
BKP-7933 V1. 00
STATION NUMBER 2
MODIFICATION COMMAND A: SET UNIT LOCATION(CAM-CCU) C: SET UNIT LOCATION(MSU) K: RESET TO DEFAULT TABLE B: SET UNIT LOCATION(CCU-RCP)
MAINTENANCE COMMAND Z: BKP-7933 CONFIGURATION
Ctrl-D RETURN
2. Move the cursor key to the desired position to be changed and press [ENTER]. using the numeric keys and press [ENTER]. Any number in the range of 1 to 1024 can be set to the SOURCE No. (maximum number of cameras) and up to 16 of the DESTINATION No. (maximum number of MSUs) can be selected. Any number in the range of 1 to 8 can be set to the LEVEL No. This setting can be assigned to the respective level and can be mapped.
SET UNIT LOCATION(MSU)
BKP-7933
V1. 00
STATION NUMBER 2
MSU MATRIX(Remote MSUs Camera Select) SOURCE No DESTINATION No 0057-0068 0057 MSU1 (CNU 0058 MSU2 (CNU 0000 MSU3 (CNU 0000 MSU4 (CNU 0000 MSU5 (CNU 0000 MSU6 (CNU 0000 MSU7 (CNU 0000 MSU8 (CNU 0000 MSU9 (CNU 0000 MSU10(CNU 0000 MSU11(CNU 0000 MSU12(CNU 0000 MSU13(CNU 0000 MSU14(CNU 0000 MSU15(CNU 0000 MSU16(CNU
GROUP GROUP GROUP GROUP GROUP GROUP GROUP GROUP GROUP GROUP GROUP GROUP GROUP GROUP GROUP GROUP
No. 0) No. 1) No. 2) No. 3) No. 4) No. 5) No. 6) No. 7) No. 8) No. 9) No. A) No. B) No. C) No. D) No. E) No. F)
LEVEL No 1
Ctrl-E RETURN TO MENU
1-26 (E)
BKP-7933
1-7. [. . . ] In such a case, setting the switches on the IF-480 board in the second slot is not necessary. (Switches are invalid even though they are set. ) ROM Replacement of the MSU-700 Replace the IC10 on the CPU-171 board of the MSU-700 with the ROM MSU-700 that is mounted in the IC socket of the ROM-25 board. Refer to the MSU-700 maintenance manual for removal of the CPU171 board. Setting of the MSU Assignment Set the control mode to the LOCAL MSU mode (LOCAL mode) using the MSU assignment menu. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE SONY BKP7933
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.