User manual SONY CCU900

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual SONY CCU900. We hope that this SONY CCU900 user guide will be useful to you.

Lastmanuals help download the user guide SONY CCU900.


Mode d'emploi SONY CCU900
Download
Manual abstract: user guide SONY CCU900

Detailed instructions for use are in the User's Guide.

[. . . ] CAMERA CONTROL UNIT CCU-900/900P DIGITAL INTERFACE UNIT BKP-9330 OPERATION MANUAL 1st Edition (Revised 3) [English] WARNING To prevent fire or shock hazard, do not expose the unit to rain or moisture. To avoid electrical shock, do not open the cabinet. Refer servicing to qualified personnel only. For customers in the USA (for CCU-900) This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. [. . . ] The signals assigned to RET 1, 2, 3, and 4 are selected using the setup menu of the CCU-900/900P, or using the MSU-700A/750 Master Setup Unit, from among the SDI, analog, SDI AUX, and PROMPTER. B AUX IN (auxiliary input) connector (BNC-type) For inputting an SDI video signal. The input signal is output via the AUX OUT connector. It is also possible to assign the signal to RET 1, 2, 3, and 4 using the setup menu of the CCU900/900P. For dual camera operation, the primary and secondary CCUs are connected using the AUX IN/OUT connectors mutually. C AUX OUT (auxiliary output) connector (BNCtype) Outputs the signal that is input via the AUX IN connector. D REFERENCE IN (reference input) connectors (BNC-type) Used to input a reference signal (sync or VS signal) for an external sync operation. Terminate the unused connector with a 75-ohm terminator. E SERIAL OUTPUT 1 to 3 connectors (BNC-type) The signal from the video camera is output as three SDI signals. If the BKP-9330 is installed, mixed signal of triplespeed signals sent from the BVP-9500WS/9500WSP are output through these connectors. Mixing is set to ON or OFF with the VPR-57 board of this unit or the MSU-700A/750 Master Setup Unit. F SERIAL OUTPUT MONI (SDI monitor output) connector (BNC-type) The signal from the video camera mixed with the character signal, skin-tone gate signal, and 4:3 marker signal is output as an SDI signal. Mixing is set to ON or OFF with the RCP-700 series or MSU-700A/750 Master Setup Unit. 10 3 Analog signal input/output connectors A RET INPUT 1 to 4 connectors B PROMPTER IN connectors C PROMPTER OUT connector D MONITOR OUT WF 1/WF 2 connectors E MONITOR OUT PIX 1/PIX 2 connectors F SYNC OUT connector 1 2 3 4 IN OUT WF1 PIX1 WF2 PIX2 RET INPUT PROMPTER MONITOR OUT SYNC OUT A RET INPUT 1 to 4 (return video 1, 2, 3, and 4 input) connectors (BNC-type) Four analog return video signals are received independently. The selection of RET 1, 2, 3, or 4 is made using the return video switch on the camera. The signals assigned to RET 1, 2, 3, and 4 are selected using the setup menu of the CCU-900/900P, or using the MSU-700A/750 Master Setup Unit, from among SDI, analog, SDI AUX, or PROMPTER. B PROMPTER IN connectors (BNC-type) Used for prompter signal input. Terminate the unused connector with a 75-ohm terminator. An analog signal of 1. 0 Vp-p, 75-ohms is output via the PROMPTER OUT connector of a video camera with a frequency bandwidth of 5 MHz, regardless of signal format. C PROMPTER OUT connector (BNC-type) Outputs the signals that are input via the PROMPTER IN connectors of the CCU-900/900P. These are analog signals of 1. 0 Vp-p, 75 ohms. D MONITOR OUT WF 1/WF 2 (waveform monitor output 1/2) connectors (BNC-type) Used for outputting a video signal for the waveform monitor selected with the MONITOR SELECT button on the RCP-700-series Remote Control Panel or the WF MONITOR button on the MSU-700A/750 Master Setup Unit. For information about these operations, refer to the Operation Manual supplied with the Master Setup Unit or Remote Control Panel. E MONITOR OUT PIX 1/PIX 2 (picture monitor output 1/2) connectors (BNC-type) Used for outputting a video signal for a picture monitor selected with the MONITOR SELECT button on the RCP-700-series Remote Control Panel, or the PICTURE MONITOR button on the MSU-700A/750 Master Setup Unit. For information about these operations, refer to the Operation Manual supplied with the Master Setup Unit or Remote Control Panel. F SYNC OUT (sync signal output) connector (BNC-type) Used for outputting a composite sync signal from the internal sync signal generator. 11 Location and Function of Parts 4 -AC IN (AC power supply input) connector Connect to an AC power supply using the supplied AC power cord. The power cord is fixed to the CCU-900/ 900P using the supplied plug holder. 5 Remote control connectors A AUX 1/AUX 2 connectors B MIC REMOTE connector C WF MODE connector D WF MODE connector E RCP/CNU connector F TRUNK LINE 1/TRUNK LINE 2 connectors AUX 1 WF MODE TRUNK LINE 1 AUX 2 MIC REMOTE RCP/CNU TRUNK LINE 2 A AUX 1/AUX 2 (auxiliary 1/auxiliary 2) connectors (D-sub 9-pin, RS-422) Used to connect the CCU-900/900P and external equipment via an RS-422 interface. B MIC REMOTE (microphone remote) connector (D-sub 15-pin) Using this connector, the video camera's microphone input level may be set from external equipment such as an audio mixer in five steps (­60, ­50, ­40, ­30, and ­20 dB). [. . . ] With a recall-type monitor, the desired display mode can first be set up on the waveform monitor (preset), and the mode can then be selected externally (recall) with the monitor select buttons on the MSU-700A/750 or on the RCP-700-series unit. The display mode and the monitor select button have the following relations: Display mode PRESET 1 PRESET 2 PRESET 3 PRESET 4 PRESET 5 PRESET 6 PRESET 7 PRESET 8 Monitor select buttons R G B SEQ or R + G + B ENC R+B R+G G+B Using DVS-V1201 SD Digital Video Routing Switchers in a cascade configuration Set REMOTE 2 unit address switch "5" of the DVS-V1201 SD Digital Video Routing Switcher to ON and all others to OFF. When connecting DVS-V1201 SD Digital Video Routing Switchers in a cascade configuration to be used with 13 or more cameras, set unit address switch "6" of the second unit to ON and the others to OFF. 22 The required cables are 1 audio cables with XLR 3-pin plugs, 2 D-sub 9-pin remote cables, 3 CCA-5 cables, and 4 75-ohm coaxial cables with BNC connectors. For details on cables without number labels, refer to the Service Manual or contact a Sony service representative. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE SONY CCU900

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual SONY CCU900 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag