User manual SONY HDSX5800

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual SONY HDSX5800. We hope that this SONY HDSX5800 user guide will be useful to you.

Lastmanuals help download the user guide SONY HDSX5800.


Mode d'emploi SONY HDSX5800
Download
Manual abstract: user guide SONY HDSX5800

Detailed instructions for use are in the User's Guide.

[. . . ] ROUTING SWITCHER PROCESSOR HDS-X5800 33 INPUT BOARD SET HKS-5810M HKS-5810SD 34 CASCADE INPUT BOARD SET HKS-5811M HKS-5811SD 33 INPUT DISTRIBUTION BOARD HKS-5820M 264x34 MATRIX BOARD HKS-5830M HKS-5830SD 34 OUTPUT BOARD SET HKS-5860M HKS-5860SD OPERATION MANUAL 1st Edition (Revised 1) [Japanese/English] , 1 2 , . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2(J) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4(J) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5(J) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] The mode that controls signals in their original form using RS-422A commands is known as Direct mode, and the mode that converts RS-422A commands to S-BUS commands is known as S-BUS Convert mode. S-BUS convert mode can control up to 1024 lines, eight levels, however the response speed is slower than in direct mode. Also, the items that can be controlled in S-BUS Convert mode are limited to those that can can be controlled in Direct mode. When S-BUS remote is set to the primary station, the mode is fixed to S-BUS Convert mode. When set to the secondary station, it is fixed to Direct mode. Simultaneous control of multiple signals with the level setting To simultaneously handle several types of signals, each type of signal requires a different routing switcher. For example, a VTR requires video, audio, time code, and remote control signals for recording. To switch these signals, these signals require video, audio, time code, and remote routing switchers respectively. You can set a maximum of sixteen levels and different input signal numbers on each level in order to simultaneously control these levels. HKS-5811SD 34 Cascade Input Board Set This is the connector board set to add 34 inputs. The set consists of a pair of 17-input boards with BNC cables attached and one 34-input equalizer board. For each single HKS-5830SD (34 outputs), one set of these boards can be mounted. These boards can handle SDTV SDI (143 Mbps to 270 Mbps) and 360 Mbps SDI. Control System of the HDSX5800 Routing Switcher System In the HDS-X5800 routing switcher system, a control unit controls the signal switching in accordance with the settings of a terminal emulator on a PC. There are four types of control available for you to control the routing system: S-BUS protocol, which is used through the BNC-type REMOTE 1 connectors; RS-422A protocol, which is used through the D-sub 9pin REMOTE 2 connectors; RS-232C protocol, which is used through the D-sub 9-pin REMOTE 3 connector; and Ethernet1) protocol, which is used through the DATA connector. Simultaneous use of four protocols is also possible. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1) Ethernet is a registered trademark of Xerox Corporation. 7 (E) Overview Functions of the HDS-X5800 Routing Switcher System The HDS-X5800 routing switcher system is equipped with the following functions: Designated input and output line protect function This function prohibits switching of protected output signals from other control panels (protect function) and prohibits switching from other control panels by hiding the input signals from all control panels (secret function). Crosspoint disable function For every output signal, you can limit the input signals available for selection so that any particular input signals can be output to the specified output lines. Password function You can enter a password to prevent unauthorized users from accessing the system. Name setting function You can set names for each input and output connector in order to distinguish among the connected signals. Two methods are available for setting the names; either enter the device name and number (i. e. name of the VTR, camera, etc. ), for example VTR 1, or a description using up to 16 characters. You can display the name on the optional BKS-R3280/R3281 display units and BKS-R1617/R3220 control units. Virtual mapping function You can set crosspoints on a virtual matrix. Free assignment function You can assign a different connector number to a connector name on each level. [. . . ] 0. 7 kg (1 lb 9 oz) (common to CNI-13 and CNI-14) Characteristics Configuration CNI-11 board (1) CNI-12 board (1) Number of inputs CNI-11 board: 17 (BNC type) CNI-12 board: 16 (BNC type) Input signal Scrambled NRZI signal, 0. 8 Vp-p Input data transfer rate 143 Mbps to 1485 Mbps Signal transfer distance 143 Mbps to 360 Mbps: 200 m (when using a BELDEN 8281 cable or equivalent) Up to 1485 Mbps: 100 m (when using a BELDEN 1694 cable or equivalent) Note CNI-13 board (1) CNI-14 board (1) Number of inputs CNI-13 board: 17 (BNC type) CNI-14 board: 16 (BNC type) Input signal Scrambled NRZI signal, 0. 8 Vp-p Input data transfer rate 143 Mbps to 360 Mbps Signal transfer distance 200 m (when using a BELDEN 8281 cable or equivalent) Note If a BNC cable is connected to an input connector with its end open, the signal detection circuit of this unit may malfunction owing to ambient noise. In such a case, terminate the end of the cable with 75 ohms. Accessory supplied Operation and installation guide (1) Design and specifications are subject to change without notice. If a BNC cable is connected to an input connector with its end open, the signal detection circuit of this unit may malfunction owing to ambient noise. In such a case, terminate the end of the cable with 75 ohms. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE SONY HDSX5800

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual SONY HDSX5800 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag