Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual SONY ICD-PX312F. We hope that this SONY ICD-PX312F user guide will be useful to you.
Lastmanuals help download the user guide SONY ICD-PX312F.
You may also download the following manuals related to this product:
SONY ICD-PX312F QUICK START GUIDE (3311 ko)
Manual abstract: user guide SONY ICD-PX312F
Detailed instructions for use are in the User's Guide.
[. . . ] 4-267-067-11(2)
IC Recorder
Operating Instructions
Getting Started Basic Operations Other Recording Operations Other Playback Operations Editing Files Listening to the FM Radio About the Menu Function Utilizing Your Computer Additional Information Troubleshooting
ICD-PX312/PX312F
To prevent possible hearing damage, do not listen at high volume levels for long periods.
WARNING
Do not expose the batteries (battery pack or batteries installed) to excessive heat such as sunshine, fire or the like for a long time. RATED CURRENT CONSUMPTION: 800 mA
Disposal of waste batteries (applicable in the European Union and other European countries with separate collection systems)
This symbol on the battery or on the packaging indicates that the battery provided with this product shall not be treated as household waste. On certain batteries this symbol might be used in combination with a chemical symbol. The chemical symbols for mercury (Hg) or lead (Pb) are added if the battery contains more than 0. 0005% mercury or 0. 004% lead. [. . . ] Marks YES: The track mark division is executed. NO: The track mark division is not executed. Move & Move File Copy File Copy Moves the selected file to the selected folder. Before attempting to move a file, select the file to be moved, and then go to the menu window. Copies the selected file from the built-in memory to the desired folder on a memory card, or from a memory card to the desired folder on the built-in memory. Before attempting to copy a file, select the file to be copied and then go to the menu window. Erases the track mark just before the current position. NO: The track mark will not be erased.
70
61
About the Menu Function
62
Delete
Erase Track Mark
66
Erase All Track Erases all the track marks of the selected file. Marks YES: All the track marks will be erased. NO: All the track marks will not be erased.
67
91
GB
Menu items Delete Erase All
Settings (*: Initial setting) Erases all files in the selected folder. Press (folder) to display the folder selection window before erasing the files and select a folder from which all files are to be erased, and then go to the menu window. YES: All files in the selected folder will be erased. Selects the memory media on which you want to store a file, or which contains the file you want to play, edit, or copy. Built-In Memory*: The built-in memory of the IC recorder is selected. Memory Card: The memory card inserted in the memory card slot is selected.
See page 64
Select Memory
43
P Note
When no memory card is currently inserted in the IC recorder, the built-in memory is automatically selected. FM Radio (for ICD-PX312F only) Auto Preset (for ICD-PX312F only) The IC recorder enters the FM radio mode. Scans automatically for available frequencies. YES: The automatic presetting is activated. NO: The automatic presetting is canceled. 75 78
92
GB
Menu items DX/LOCAL (for ICD-PX312F only)
Settings (*: Initial setting) Sets the receiver sensitivity when listening to the FM radio. LOCAL: When there is interference or collapsing caused by a intense electric field around the transmitting antenna of the broadcasting station, etc. , select this setting.
See page 81
P Note
Select "DX" when the IC recorder reception status is not good due to a weak signal. Scan Sensitivity (for ICD-PX312F only) Sets the scanning sensitivity when presetting FM radio stations. [. . . ] when you divide a file.
140
GB
Display Window Guide
Display when stopped
D Folder name indicator E File information indicator You can switch the file information display in order by pressing DISP/ MENU briefly: Elapsed time c Remaining time c Recording date and time c File name c Title c Artist name : File name : Title : Artist name (during playback only) F File location indicator The selected file number is displayed in the numerator and the total number of files in the folder is displayed in the denominator. G Protect indicator Appears when the protection is set for a file. H Alarm indicator I Remaining memory indicator Displays the remaining memory and decreases one by one during recording.
A Track mark indicator Displays the track mark number just before the current position. Appears when a track mark is set for a file. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE SONY ICD-PX312F
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.
Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual SONY ICD-PX312F will begin.