User manual SONY VAIO VPC-EB1CGX/BI

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual SONY VAIO VPC-EB1CGX/BI. We hope that this SONY VAIO VPC-EB1CGX/BI user guide will be useful to you.

Lastmanuals help download the user guide SONY VAIO VPC-EB1CGX/BI.


Mode d'emploi SONY VAIO VPC-EB1CGX/BI
Download

You may also download the following manuals related to this product:

   SONY VAIO VPC-EB1CGX/BI HARD DISK DRIVE REPLACEMENT INSTRUCTIONS (1855 ko)
   SONY VAIO VPC-EB1CGX/BI OPTICAL DISK DRIVE REPLACEMENT INSTRUCTIONS (1102 ko)

Manual abstract: user guide SONY VAIO VPC-EB1CGX/BI

Detailed instructions for use are in the User's Guide.

[. . . ] [. . . ] T V0 W0 W2 X0 X2 X4 Z1 &C1 &D0 Function Command Re-execute command A Select V. 22 connect @1200 bps B1 Return OK message Dn Turn off command echo E1 Initiate a hang-up sequence H1 Report product code Report pre-computed checksum I2 Report firmware revision, model, and interface type Report response programmed by OEM I5 Report modem data pump model I7 and code revision L0 Set low speaker volume L2 Set high speaker volume M0 Turn speaker on during handshaking M2 and turn speaker off while receiving carrier M3 Turn off automode detection Turn on automode detection Go on-line O1 Force pulse dialing Q0 Inhibit result codes to DTE Sn Return the value of S-Register n Sn=v Force DTMF dialing Report short form result codes V1 Report DTE speed only W1 Report DCE speed only Report basic call progress result codes, X1 i. e. , Ok, Connect, Ring, No Carrier (also, for busy, if enabled, and dial tone not detected), No Answer and Error Report basic call progress result codes and connections speeds, i. e. , Ok, X3 Connect, Ring, No Carrier (also, for busy, if enabled, and dial tone not detected), No Answer, Connect XXXX, and Error Y0 Report all call progress result codes and connections rate, i. e. , Ok, Connect, Y1 Ring, No Carrier, No Answer, Connect XXXX, Busy, No Dial Tone and Error Z0 Soft reset and restore stored profile 1 &C0 after warm reset Allow RLSD to follow the carrier state Interpret DTR On-to-OFF transition &D1 per &Qn &Q0, &Q5, &Q6 The modem ignores DTR &Q1, &Q4 The modem hangs up &Q2, &Q3 The modem hangs up Function Go off-hook and attempt to answer a call Select Bell 212A connect @1200 bps Dial modifier Turn on command echo If on-hook, go off-hook and enter command mode Report "OK" if the calculated checksum equals the prestored checksum or if the prestored checksum value is FFh Report the country code parameter Report the DAA code Set low speaker volume Set medium speaker volume Turn speaker off Turn speaker on during handshaking and while receiving carrier Turn speaker off during dialing and receiving carrier and turn speaker on during answering Go on-line and initiate a retrain sequence Allow result codes to DTE Select S-Register n as default Set default S-Register n to value v Report long form result codes Report line speed, EC protocol and DTE speed Report basic call progress result codes and connections speeds (Ok, Connect, Ring, No Carrier (also, for busy, if enabled, and dial tone not detected), No Answer, Connect XXXX, and Error Report basic call progress result codes and connections rate, i. e. , Ok, Connect, Ring, No Carrier, No Answer, Connect XXXX, Busy, and Error Disable long space disconnect before onhook Enable long space disconnect before onhook Restore stored profile 0 after warm reset Soft reset and force RLSD active regardless of the carrier state Interpret DTR On-to-OFF transition per &Qn &Q0, &Q1, &Q4, &Q5, &Q6 Asynchronous escape &Q2, &Q3 The modem hangs up &D2 Interpret DTR On-to-OFF transition per &Qn &Q0 through &Q6 The modem hangs up &D1 Interpret DTR On-to-OFF transition per &Qn &Q0, &Q1, &Q4, &Q5, &Q6 Soft reset &Q2, &Q3 The modem hangs up Note: Bold face indicates default value &F0 Restore factory configuration 0 &F1 Restore factory configuration 1 &G0 &G2 &J1 Disable guard tone &G1 Disable guard tone Enable 1800 Hz guard tone &J0 Set S-Register response only for comSet S-Register response only for compatibility patibility &K0 Disable DTE/DCE flow control &K3 Enable RTS/CTS DTE/DCE flow &K4 Enable XON/XOFF DTE/DCE flow control control &K5 Enable transparent XON/ XOFF &K6 Enable both RTS/CTS and XON/XOFF flow control flow control &L0 Select dial up line operation &M0 Select direct asynchronous mode &M1 Select sync connect with async off&M2 Select sync connect with async offline command mode line command mode and enable DTR &M3 Select sync connect with async offdialing of directory zero line command mode and enable DTR &P0 Set 10 pps pulse dial with 39%/61% to act as Talk/Data switch make/break &P1 Set 10 pps pulse dial with 33%/67% &P2 Set 20 pps pulse dial with 39%/61% make/break make/break &P3 Set 20 pps pulse dial with 33%/67% &Q0 Select direct asynchronous mode make/break &Q1 Select sync connect with async off&Q2 Select sync connect with async offline command mode line command mode and enable DTR &Q3 Select sync connect with async offdialing of directory zero line command mode and enable DTR &Q4 Select Hayes AutoSync mode to act as Talk/Data switch &Q5 Modem negotiates an error corrected &Q6 Select asynchronous operation in normal link mode &R0 CTS tracks RTS (sync) or CTS is &R1 CTS is always active (sync) or CTS is normally ON and will turn OFF normally ON and will turn OFF only if required by flow control (async) only if required by flow control (async) &S0 DSR is always active &S1 DSR will become active after answer &T0 Terminate any test in progress tone has been detected and inactive after &T1 Initiate local analog loopback the carrier has been lost &T2 Returns ERROR result code &T3 Initiate local digital loopback &T4 Allow remote digital loopback (RDL) &T5 Disallow remote digital loopback request &T6 Request an RDL without self-test &T7 Request an RDL with self-test &T8 Initiate local analog loop with self&V Display current configuration and stored test profiles &V1 Display last connection statistics &W0 Store the current configuration as &W1 Store the current configuration as profile 0 profile 1 &X0 Select internal timing for the transmit &X1 Select external timing for the transmit clock clock &X2 Select slave receive timing for the &Y0 Recall stored profile 0 upon power up transmit clock &Y1 Recall stored profile 1 upon power up &Zn=x Store dial string x (up to 34 digits) %E0 Disable line quality monitor and auto to location n (0 to 3) retrain %E1 Enable line quality monitor and auto %E2 Enable line quality monitor and fallback/ retrain fall forward %L Return received line signal level %Q Report the line signal quality When modem receives a break from the DTE: \K0, 2, 4 Enter on-line command mode, no \K1 Clear buffers and send break to remote break sent to the remote modem modem \K3 Send break to remote modem \K5 Send break to remote modem in sequence immediately with transmitted data When modem receives \B in on-line command state: \K0, 1 Clear buffers and send break to remote \K2, 3 Send break to remote modem immediately modem \K4, 5 Send break to remote modem in sequence with transmitted data When modem receives break from the remote modem: \K0, 1 Clear data buffers and send break to \K2, 3 Send a break immediately to DTE DTE \N0 \N2 \N4 \V0 +MS (RPI) +H1 +H3 **0 -SDR=0 -SDR=2 -SDR=4 -SDR=6 \K4, 5 Select normal speed buffered mode \N1 Select reliable link mode \N3 Force LAPM mode \N5 Connect messages are controlled \V1 by the command settings X, W, and S95 Select modulation +H0 Enable RPI and set DTE speed to 19200 bps Enable RPI and set DTE speed to 57600 bps Download to flash memory at last sensed speed Disable distinctive ring Enable distinctive ring type 2 Enable distinctive ring type 3 Enable distinctive ring type 2 and 3 Send a break with received data to the DTE Select direct mode Select auto reliable mode Force MNP mode Connect messages are displayed in the single line format Disable Rockwell Protocol Interface +H2 +H11 +H16 **1 **2 -SDR=1 -SDR=3 -SDR=5 -SDR=7 /Video ready mode Enable RPI and set DTE speed to 38400 bps Enable RPI+ mode Enable Video Ready mode Download to flash memory at 38. 4 kbps Download to flash memory at 57. 6 kbps Enable distinctive ring type 1 Enable distinctive ring type 1 and 2 Enable distinctive ring type 1 and 3 Enable distinctive ring type 1, 2 and 3 ECC Commands %C0 %C2 \A0 \A2 \Bn Disable data compression Enable V. 42 bis data compression %C1 %C3 Enable MNP 5 data compression Enable both V. 42 bis and MNP 5 compression Set maximum block size in MNP to 128 Set maximum block size in MNP to 256 Set maximum block size in MNP to 64 \A1 Set maximum block size in MNP to 192\A3 Send break of n x 100 ms MNP 10 Commands -K0 -K2 Disable MNP 10 extended services -K1 Enable MNP 10 extended services Disable MNP 10 extended services -SEC=0 Disable MNP 10-EC detection only -SEC=1, [<tx level>] Enable MNP 10-EC and set transmit level<tx level> 0 to 30 (0 dBm to -30 dBm) FAX Class 1 +Fclass=1 Service class +FAE=1 Enable data/fax auto answer +FRM=n Receive data +FTH=n Transmit data with HDLC framing +FTS=n Stop transmission and wait, nx10 ms +FAE=0 +FRH=n +FRS=n +FTM=n Disable data/fax auto answer Receive data with HDLC framing Receive silence, nx10 ms Transmit data W-Class Commands AT*Commends *B Display Blacklisted Number *Cn Data Calling tone (1300hz)selection *NC Country select *NCn Code(n) Country 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 USA Japan Germany UK(CTR-21) France Austria Italy Australia Sweden Denmark New Zealand Korea China Singapore Malaysia South Africa Poland Czechoslovakia Hungary Hong Kong Turkey Spain %Tn PTT Testing of Signal Level %TT00_%TT09 Dual Tone Multifrequency ( DTMF ) tone dial digits 0 to 9 %TT0A DTMF digit * %TT0B DTMF digit # %TT0C DTMF digit A %TT0D DTMF digit B %TT0E DTMF digit C %TT0F DTMF digit D %TT10 V. 21 Channel 1mark ( originate ) symbol. %TT15 V. 22 originate signaling at 1200 bps %TT16 V. 22 bis originate signaling at 2400 bps %TT17 V. 22 answering signaling ( guard tone if PTT required). %TT31 V. 25 answer tone %TT32 1800Hz guard tone %TT33 V. 25 calling tone ( 1300 Hz ) %TT34 Fax calling tone ( 1100 Hz ) %TT40 V. 21 channel 2 %TT41 V. 27 ter 2400 bps %TT42 V. 27 ter 4800 bps %TT43 V. 29 7200 bps %TT44 V. 29 9600 bps %TT45 V. 17 7200 bps long train %TT46 V. 17 7200 bps short train %TT47 V. 17 9600 bps long train %TT48 V. 17 9600 bps short train %TT49 V. 17 12000 bps long train %TT4A V. 17 12000 bps short train %TT4B V. 17 14400 bps long train %TT4C V. 17 14400 bps short train %TT60 2400 bps ( V. 34 only ) %TT61 4800 bps ( V. 34 only ) %TT62 7200 bps (V. 34 only ) %TT63 9600 bps (V. 34 only ) %TT64 12000 bps (V. 34 only) %TT65 14400 bps %TT66 16800 bps %TT67 19200 bps %TT68 21600bps %TT69 24000 bps %TT6A 26400bps %TT6B 28800bps %TT6C 31200bps %TT6D 33600bps S-Registers Register Function S0 Rings to auto-answer S1 Ring counter S2 Escape character S3 Carriage return character S4 Line feed character S5 Backspace character S6 Wait time for dial tone S7 Wait time for carrier S8 Pause time for dial delay modifier S9 Carrier detect response time S10 Carrier loss disconnect time S11 DTMF tone duration S12 Escape prompt delay S14 General bit mapped options status S16 Test mode bit mapped options status (&T) S18 Test timer S19 AutoSync options S20 AutoSync HDLC address or BSC Sync character S21 V. 24/general bit mapped options status S22 Speaker/results bit mapped options status S23 General bit mapped options status S24 Sleep inactivity timer S25 Delay to DTR off S26 RTS-to-CTS delay S27 General bit mapped options status S28 General bit mapped options status S29 Flash dial modifier time S30 Disconnect inactivity timer S31 General bit mapped options status S32 XON character S33 XOFF character S36 LAPM failure control S37 Line connection speed S38 Delay before forced hangup S39 Flow control bit mapped options status S40 General bit mapped options status S41 General bit mapped options status S46 Data compression control S48 V. 42 negotiation control S82 LAPM break control S86 Call failure reason code S91 PSTN transmit attenuation level S92 Fax transmit attenuation level S95 Result code messages control Range/units 0-255/rings 0-255/rings 0-255/ASCII 0-127/ASCII 0-127/ASCII 0-255/ASCII 2-255/s 1-255/s 0-255/s 1-255/. 1 s 1-255/. 1 s 50-255/. 001 s 0-255/. 02 s Default 0 0 43 13 10 8 2 50 2 6 14 95 50 138 (8Ah) 0 0 0 0 52 (34h) 117 (75h) 62 (3Dh) 0 5 1 73 (49h) 0 70 0 194 (C2h) 17 (11h) 19 (13h) 7 0 20 3 104 (68h) 195(C3h) 138 7 128 (40h) 10 (country dependent) 10 (country dependent) 0 0-255/s 0-255 0-255/s 0-255/s or . 01s 0-255/. 01 s 0-255/10 ms 0-255/10 s 0-255/ASCII 0-255/ASCII 0-255/s 0-255 0-15/dBm 0-15/dBm Result Code Summary OK RING ERROR NO DIAL TONE NO ANSWER CONNECT 2400 CONNECT 9600 CONNECT 12000 CONNECT 19200 CONNECT 57600 CONNECT 230400 CONNECT 1200TX/75RX BLACKLISTED DATA CARRIER 1200/75 CARRIER 1200 CARRIER 4800 CARRIER 9600 CARRIER 14400 CARRIER 19200 CARRIER 24000 CARRIER 28800 CONNECT 21600 CONNECT 26400 COMPRESSION: CLASS 5 COMPRESSION: NONE PROTOCOL: LAPM CARRIER 33600 CONNECT 31200 CARRIER 34000 CARRIER 38000 CARRIER 42000 CARRIER 46000 CARRIER 50000 CARRIER 54000 CONNECT 32000 CONNECT 36000 CONNECT 40000 CONNECT 44000 CONNECT 48000 CONNECT 52000 CONNECT 56000 0 2 4 6 8 10 12 14 16 18 20 23 32 35 44 46 48 50 52 54 56 58 61 63 66 69 77 79 91 151 153 155 157 159 161 165 167 169 171 173 175 177 CONNECT NO CARRIER CONNECT 1200 BUSY CONNECT 0600 CONNECT 4800 CONNECT 7200 CONNECT 14400 CONNECT 38400 CONNECT 115200 CONNECT 75TX/1200RX DELAYED FAX CARRIER 300 CARRIER 75/1200 CARRIER 2400 CARRIER 7200 CARRIER 12000 CARRIER 16800 CARRIER 21600 CARRIER 26400 CONNECT 16800 CONNECT 24000 CONNECT 28800 COMPRESSION: V. 42 bis PROTOCOL: NONE CARRIER 31200 CONNECT 33600 CARRIER 32000 CARRIER 36000 CARRIER 40000 CARRIER 44000 CARRIER 48000 CARRIER 52000 CARRIER 56000 CONNECT 34000 CONNECT 38000 CONNECT 42000 CONNECT 46000 CONNECT 50000 CONNECT 54000 +FCERROR 1 3 5 7 9 11 13 15 17 19 22 24 33 40 45 47 49 51 53 55 57 59 62 64 67 70 78 84 150 152 154 156 158 160 162 166 168 170 172 174 176 +F4 [. . . ] [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE SONY VAIO VPC-EB1CGX/BI

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual SONY VAIO VPC-EB1CGX/BI will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag