If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual SONY VAIO VPC-EB1RGX/BI. We hope that this SONY VAIO VPC-EB1RGX/BI user guide will be useful to you.
Lastmanuals help download the user guide SONY VAIO VPC-EB1RGX/BI.
You may also download the following manuals related to this product:
SONY VAIO VPC-EB1RGX/BI DATASHEET (714 ko)
SONY VAIO VPC-EB1RGX/BI HARD DISK DRIVE REPLACEMENT INSTRUCTIONS (1855 ko)
SONY VAIO VPC-EB1RGX/BI OPTICAL DISK DRIVE REPLACEMENT INSTRUCTIONS (1102 ko)
Manual abstract: user guide SONY VAIO VPC-EB1RGX/BI
Detailed instructions for use are in the User's Guide.
[. . . ] are trademarks of the AMD Corporation in the U. S. All other product names mentioned herein may be trademarks of their respective companies. Compaq shall not be liable for technical or editorial errors or omissions contained herein. The information in this document is provided "as is" without warranty of any kind and is subject to change without notice. [. . . ] Handle these items only at static-free workstations. Avoid contact with pins, leads, or circuitry. Turn off power and input signals before inserting or removing connectors or test equipment.
I I
Maintenance and Service Guide
45
Removal and Replacement Preliminaries
4. 7 Grounding Equipment and Methods
Grounding equipment must include either a wrist strap or a foot strap at a grounded workstation.
I
When seated, wear a wrist strap connected to a grounded system. Wrist straps are flexible straps with a minimum of one megohm ±10% resistance in the ground cords. To provide proper ground, wear a strap snugly against the skin at all times. On grounded mats with banana-plug connectors, connect a wrist strap with alligator clips. When standing, use foot straps and a grounded floor mat. Foot straps (heel, toe, or boot straps) can be used at standing workstations and are compatible with most types of shoes or boots. On conductive floors or dissipative floor mats, use foot straps on both feet with a minimum of one-megohm resistance between the operator and ground. To be effective, the conductive strips must be worn in contact with the skin.
I
Other grounding equipment recommended for use in preventing electrostatic damage includes:
I I I I I I I I I
Antistatic tape Antistatic smocks, aprons, and sleeve protectors Conductive bins and other assembly or soldering aids Nonconductive foam Conductive tabletop workstations with ground cords of one-megohm resistance Static-dissipative tables or floor mats with hard ties to the ground Field service kits Static awareness labels Material-handling packages
46
Maintenance and Service Guide
Removal and Replacement Preliminaries
I I I
Nonconductive plastic bags, tubes, or boxes Metal tote boxes Electrostatic voltage levels and protective materials
Table 4-1 shows how humidity affects the electrostatic voltage levels generated by different activities.
Table 4-1 Typical Electrostatic Voltage Levels
Relative Humidity Event Walking across carpet Walking across vinyl floor Motions of bench worker Removing DIPS from plastic tube Removing DIPS from vinyl tray Removing DIPS from Styrofoam Removing bubble pack from PCB Packing PCBs in foam-lined box 10% 35, 000 V 12, 000 V 6, 000 V 2, 000 V 11, 500 V 14, 500 V 26, 500 V 21, 000 V 40% 15, 000 V 5, 000 V 800 V 700 V 4, 000 V 5, 000 V 20, 000 V 11, 000 V 55% 7, 500 V 3, 000 V 400 V 400 V 2, 000 V 3, 500 V 7, 000 V 5, 000 V
A product can be degraded by as little as 700 volts.
Table 4-2 lists the shielding protection provided by antistatic bags and floor mats.
Table 4-2 Static-Shielding Materials
Material Antistatic plastic Carbon-loaded plastic Metallized laminate Use Bags Floor mats Floor mats Voltage Protection Level 1, 500 V 7, 500 V 5, 000 V
Maintenance and Service Guide
47
5
Removal and Replacement Procedures
This chapter provides removal and replacement procedures. Phillips P1 and Torx T8 screws are removed during disassembly. Swing the right side of the hard drive up and to the left until it is resting at an angle (Figure 5-6). Lift the hard drive straight up and remove it 2.
Figure 5-6. Removing the Hard Drive
Maintenance and Service Guide
59
Removal and Replacement Procedures
5. If the hard drive must be removed from the hard drive bezel, perform the following steps: a. Remove the four silver PM2. 5 × 3. 5 screws 1 that secure the hard drive to the hard drive bezel (Figure 5-7). Slide the hard drive forward 2 and remove it from the hard drive bezel.
Figure 5-7. Removing the Hard Drive from the Hard Drive Bezel
is included The hard drive bezel254121-001). in the Plastics and Hardware Kit (spare part number Reverse the above procedure to install the hard drive.
510
Maintenance and Service Guide
Removal and Replacement Procedures
5. 4 Computer Feet
The computer feet are adhesive-backed rubber pads. The computer feet are included in the Plastics and Hardware Kit (spare part number 254121-001). The computer feet attach to the battery bracket and hard drive bezel as illustrated in Figure 5-8.
Figure 5-8. Replacing the Computer Feet
5. 5 Memory Expansion Board
Memory Expansion Boards Spare Part Number Information
Memory expansion boards 256 MB 128 MB 244399-001 239190-001
Maintenance and Service Guide
511
Removal and Replacement Procedures
1. Prepare the computer for disassembly (Section 5. 3). [. . . ] The power cord set must have a minimum current capacity of 10 amps and a nominal voltage rating of 125 or 250 volts AC, as required by each country's power system. The appliance coupler must meet the mechanical configuration of an EN 60 320/IEC 320 Standard Sheet C13 connector, for mating with the appliance inlet on the back of the computer.
I
I
Maintenance and Service Guide
B1
Power Cord Set Requirements
Country-Specific Requirements
3-Conductor Power Cord Set Requirements
Country Australia Austria Belgium Canada Denmark Finland France Germany Italy Japan The Netherlands Norway Sweden Switzerland United Kingdom United States Accredited Agency EANSW OVE CEBC CSA DEMKO FIMKO UTE VDE IMQ METI KEMA NEMKO SEMKO SEV BSI UL Applicable Note Number 1 1 1 2 1 1 1 1 1 3 1 1 1 1 1 2
Notes
1. The flexible cord must be <HAR> Type HO5VV-F, 3-conductor, 1. 0 mm2 conductor size. Power cord set fittings (appliance coupler and wall plug) must bear the certification mark of the agency responsible for evaluation in the country where it will be used.
B2
Maintenance and Service Guide
Power Cord Set Requirements
2. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE SONY VAIO VPC-EB1RGX/BI
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.