User manual SOUNDCRAFT DELTA MONITOR V2

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual SOUNDCRAFT DELTA MONITOR. We hope that this SOUNDCRAFT DELTA MONITOR user guide will be useful to you.

Lastmanuals help download the user guide SOUNDCRAFT DELTA MONITOR.


Mode d'emploi SOUNDCRAFT DELTA MONITOR
Download
Manual abstract: user guide SOUNDCRAFT DELTA MONITORV2

Detailed instructions for use are in the User's Guide.

[. . . ] The DS2416 outputs can be connected to any 328 input ­ Stereo 1 for example. The inputs can be derived from any 328 output, such as a pair of aux sends or the mix output, depending on how you wish to record. Spirit Digital 328 v2 2 Digital 328 Setup To configure the Digital 328 as the wordclock master, enter the 328 Menu pages by pressing the <MENU> button on the right hand side of the LCD display. [. . . ] Here, the sample rate at which you wish to work is also determined. Select `Internal:44. 1kHz' or `Internal:48. 0kHz', depending on the chosen sample rate: 2 <Wordclock Src. > Internal:44. 1kHz or <Wordclock Src. > Internal:48. 0kHz S/PDIF Input The S/PDIF Input on the console must be routed to a suitable destination. The available options are one of the 2 Stereo Inputs, one of the 2 FX Returns or as a Digital 2 Track Return. NOTE Selecting one of these destinations will override an analogue signal present at that input. So, the input which should be used will depend on which other inputs are connected. It is likely that the most suitable input would be either Stereo 2 or as a digital 2 Track Return. Enter the menu pages by pressing the <MENU> button on the right hand side of the LCD display. Using the encoder beneath the display, scroll up or down until the `SPDIF I/P Setup' menu is highlighted and press <ENTER>. C-Console provides stand alone control of the DS2416's functions without requiring direct integration into a sequencer package. For further information visit http://www. c-mexx. com. 3 NOTE DS2416 Patch Utility The DS2416 Patch Utility is also required. This should also be downloaded from the Yamaha website: http://www. yamaha. co. jp/product/proaudio/homeenglish/navi/index. htm This enables the card to be set to slave to the 328's master clock. Wordclock Run the patch. exe application. First click the `DIO #1' tab and set the clock source to DI (Digital In) so that the card slaves to the 328 master clock as shown below: Yamaha DS2416 Setup Guide 5 NOTE Do not close the DS2416 Patch application as the card's clock will revert to its default internal state. Configuring DS2416 S/PDIF I/O If using the patch. exe application alone (ie without an application such as C-Console), it must also be used to activate the DS2416 S/PDIF input. NOTE Click on the `Master & InPatch #1' tab and activate the S/PDIF inputs by clicking both S/PDIF switches: The pan controls should also be panned hard left and right and the Stereo output activated: The 328 SPDIF output will then be routed into the DS2416 card available for hard disk recording and the output will be routed to the 328 input as selected on page 3. Spirit Digital 328 v2 6 C-Mexx C-Mexx C-Console If using C-Mexx C-Console for control of the DS2416, the digital S/PDIF input appears again on channels 19 and 20 but C-Console of course offers far more control. NOTE patch. exe must still be run and left active in the background if slaving clock from the 328. If using the DS2416 as the master clock source, patch. exe does not need to be run. Open C-Console and click View | In Patch | New and ensure that the S/PDIF input is set to be active on channels 19 and 20 as shown (left). The 328 S/PDIF output will now appear on channels 19 and 20 on the DS2416 C-Console control surface as indicated on the following page. [. . . ] The 328 S/PDIF output will now appear on channels 19 and 20 on the DS2416 C-Console control surface as indicated on the following page. From this input the 328 S/PDIF output can be routed to other software applications for hard disk recording. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE SOUNDCRAFT DELTA MONITOR

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual SOUNDCRAFT DELTA MONITOR will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag