Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual SOUNDCRAFT RM105. We hope that this SOUNDCRAFT RM105 user guide will be useful to you.
Lastmanuals help download the user guide SOUNDCRAFT RM105.
Detailed instructions for use are in the User's Guide.
[. . . ] Soundcraft shall not be liable for any loss or damage whatsoever arising from the use of information or any error contained in this manual, or through any mis-operation or fault in hardware contained in the product. No part of this manual may be reproduced, stored in a retrieval system, or transmitted, in any form or by any means, electronic, electrical, mechanical, optical, chemical, including photocopying and recording, for any purpose without the express written permission of Soundcraft. It is recommended that all maintenance and service on the product should be carried out by Soundcraft or its authorised agents. Soundcraft cannot accept any liability whatsoever for any loss or damage caused by service, maintenance or repair by unauthorised personnel.
Harman International Industries Ltd. [. . . ] When the CUE is switched off the monitor returns to the original source.
Presenter's Headphones
9 Six SOURCE SELECT switches provide a choice of External Inputs 1-4, PGM
or AUD as the source for the headphones.
10 The LEVEL control sets the level of the headphone signal. 11 The headphone output is a 3-pole 1/4" jack. 12 The meterbridge is fitted with a pair of VU meters as standard. The METER SELECT switches provide a choice of PGM, AUD or MON (C/Room Monitor) as the source for the meters. Note that the MON position provides a means of monitoring the external inputs via the C/Room Monitor source selection.
On the larger frame sizes an additional pair of meters may be fitted, and in this case one pair of meters will always display the PGM output.
Power Input
The 5way locking POWER connector is the power input to the console. The console requires +17V, 17V and +48V.
Rear Connector Panel
Master Module
4. 17
Specifications
PGM, AUD & Mono
Max. output Output impedance +26dBu into 600 <75
General
THD Crosstalk < 0. 02% < -80dB @ 20kHz
4. 18
Master Module
0HWHUEULGJH
Two meterbridge styles are available. The following facilities are provided as standard:
1 a single pair of VU meters (PPM meters optional). These display the level of the source selected by the METER SELECT switches, and can be calibrated by means of two screwdriver presets on the Master Panel (see earlier in this chapter).
The following facilities are only available on the optional meterbridge:
2 4-digit TIMER MODULE. This can be programmed by internal jumpers on the stereo modules to start automatically when the stereo channel is activated, or controlled manually by the local switches. 3 The CUE SPEAKER and associated LEVEL control monitor the output of the CUE bus
2
1
3
Master Module
4. 19
6WHUHR6RXUFH6HOHFW0RGXOH
The Stereo Source Select module provides switching from 8 balanced stereo sources, which are presented on a 38-way male EDAC connector to two independent balanced stereo outputs on a 15-way male D-type connector. The benefit of this Warranty may not be assigned by the End User. End Users who are consumers should note their rights under this Warranty are in addition to and do not affect any other rights to which they may be entitled against the seller of the Equipment.
3 4
6. 7.
A. 4
Appendices
CPS150 Power Supply
CPS150 Power Supply
43
CPS150 User & Technical Manual
IMPORTANT: PLEASE READ THIS MANUAL CAREFULLY BEFORE CONNECTING YOUR SOUNDCRAFT CPS150 POWER SUPPLY TO THE MAINS FOR THE FIRST TIME.
WARNING SYMBOLS For your own safety and to avoid invalidation of the warranty all text marked as this paragraph should be read carefully.
FOR UK USERS ONLY
IMPORTANT WARNING THIS APPLIANCE MUST BE EARTHED
The wires in the mains lead are coloured in accordance with the following code: Green and Yellow: Blue: Brown: Earth Neutral Live
As the colours of the wires in the mains lead may not correspond with the coloured markings identifying the terminals in your plug, proceed as follows: · · · The wire which is coloured Green and Yellow must be connected to the terminal in the plug which is marked with the letter E or by the earth symbol. The wire which is coloured Blue must be connected to the terminal in the plug which is marked with the letter N or coloured Black. The wire which is coloured Brown must be connected to the terminal in the plug which is marked with the letter L or coloured Red.
CPS 150
P. 1
Introducing the CPS150
The CPS150 is a linear power supply which, like other linear supplies, produces DC voltages by rectifying, smoothing and regulating AC voltages from the secondary windings of a mains transformer. In regulating these voltages there is some heat generated, the dissipation of which is achieved through a ventilated cover. The CPS150 is designed to be free standing or it can be installed in a 19" rack. For rack mounting, an optional front panel provided with the necessary fixing holes can be obtained from Soundcraft (Part No. Refer to the section "RECOMMENDATIONS FOR INSTALLATION" for details. LED indication is provided on the front panel to show indication of operation of all regulating circuits.
SAFETY APPROVAL: HD 195 S6 TYPE TESTED
This manual covers the CPS 150 unit, that has been type tested and conforms to the CENELEC Harmonised Document HD195 S6, consisting of IEC 65 (1985)ed 5 and BS 415 1990, with CENELEC deviations.
EMC CONDUCTED EMISSION
Certification of Conformity has been received for both: USA Statutory Emission Requirements (FCC CFR47 Part 15J, A and B) German Statutory Emission Requirements (VDE0871, A and B)
P. 2
CPS 150
Mains Voltage Selection
Special attention should be given to the following information:
This unit is capable of operating over a wide range of mains voltages by means of a comprehensive set of selectable voltage settings. It is important to ensure that the correct voltage setting has been selected for the level of local mains voltage supply, for safe, uninterrupted operation of the unit. [. . . ] Again, an insulating SIL pad is used and this should be replaced if it appears to be damaged. The metal tab at the top of the package is at the output potential of the device, as is the centre lead. When refixing or replacing the device, it is preferable to screw the device down before resoldering the leads, to avoid placing a strain on the circuit board pads.
NOTE that the heatsink bracket is earthed through its mechanical contact with the rest of the chassis and so a faulty SIL pad may cause the output of its regulator to be connected to earth. In the case of a positive voltage rail the output then becomes short circuited when the mixing console is connected. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE SOUNDCRAFT RM105
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.
Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual SOUNDCRAFT RM105 will begin.