Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual SUB-ZERO 30GASCOOKTOP. We hope that this SUB-ZERO 30GASCOOKTOP user guide will be useful to you.
Lastmanuals help download the user guide SUB-ZERO 30GASCOOKTOP.
Detailed instructions for use are in the User's Guide.
[. . . ] Merely turn down the illuminated knob and the lower-tier burners delivers finetuning control and True Simmer. This patented feature allows you to have the slightest of flame and enjoy a simmer with no boiling or scorching. Available in your choice of classic or platinum stainless steel finish. The sealed burners and deep recess of the seamless drawn pan area make clean up of any of those previously unsightly spills a snap. [. . . ] IMPORTANT NOTE: A ground fault circuit interrupter (GFCI) is not recommended and may cause interruption of operation. When a gas cooktop is installed above cabinets, the gas and electrical placement is not critical. A grounded outlet needs to be placed within 4' (1. 2 m) of the right rear of the cooktop. A Wolf 30" (762) built-in single oven may be installed below this cooktop. For this installation, the electrical and gas supply for the cooktop should be installed in the adjacent cabinet. Refer to page 6 for additional specifications. Be aware of the depth of the cooktop when planning for this installation. IMPORTANT NOTE: Wolf gas cooktops are designed and agency approved for installation with Wolf built-in ovens only.
IMPORTANT NOTE: When a oven is installed below the cooktop, unless you are using cabinets deeper than 24" (610), it is recommended that the electrical supply for the oven be placed in an adjacent cabinet within reach of the conduit. A 2" (51) diameter hole to route the conduit through cabinetry will be required. Refer to page 6 for location of electrical supply and additional specifications. Wolf gas cooktops are designed to operate on natural gas at 5" (12. 5 mb) WC (water column) pressure or LP (propane) gas at 10" (25 mb) WC pressure. The minimum line pressure for natural gas is 7" (17. 5 mb) WC and 11" (27. 4 mb) WC for LP gas. The maximum gas supply pressure to the regulator should never exceed 14" (34. 9 mb) WC; . 5 psi (3. 5 kPa). The cooktops are supplied with a 1/2" NPT male gas connection at the right rear bottom corner of the cooktop. The male connector exits the unit straight down and you are supplied with a regulator with two female connectors. Wolf gas cooktops using natural gas function up to an altitude of 8, 000' (2438 m) without any adjustment. Natural gas installations from 8, 000' (2438 m) to 10, 000' (3048 m) need the high altitude conversion kit. LP gas installations will operate up to 10, 000' (3048 m) without adjustment. You must follow all National Electrical Code and gas regulations. In addition, be aware of local codes and ordinances when installing your services. [. . . ] Some Wolf integrated modules can be installed together or with a 30" (762) or 36" (914) cooktop. When multiple units are installed side by side, the cut-out dimensions that are shown in the illustration are derived by adding 1 1/4" (32) additional space for each additional unit, to give you your total cut-out width. Refer to the illustration below for countertop cut-out dimensions for installation of multiple cooktops. IMPORTANT NOTE: Refer to the pages for each specific integrated module for installation limitations.
IMPORTANT NOTE: Where multiple cooktops and/or modules are installed side by side, each unit must have its own separate recommended electrical circuit. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE SUB-ZERO 30GASCOOKTOP
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.
Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual SUB-ZERO 30GASCOOKTOP will begin.