User manual SUB-ZERO 36GASCOOKTOP

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual SUB-ZERO 36GASCOOKTOP. We hope that this SUB-ZERO 36GASCOOKTOP user guide will be useful to you.

Lastmanuals help download the user guide SUB-ZERO 36GASCOOKTOP.


Mode d'emploi SUB-ZERO 36GASCOOKTOP
Download
Manual abstract: user guide SUB-ZERO 36GASCOOKTOP

Detailed instructions for use are in the User's Guide.

[. . . ] Dimensions in parentheses are in millimeters unless otherwise specified. 2 Planning Information Model CT36G 36" (914) Gas Cooktop S P E C I F I C AT I O N S Overall Cooktop Width Overall Cooktop Height Model CT36G 36" (914) 4" (102) 21" (533) 35" (889) 19 1/4" (489) 22 3/4" (578) Overall Cooktop Depth Cooktop Cut-Out Width Cooktop Cut-Out Depth MODEL OPTIONS Minimum Cabinet Depth Classic Stainless Steel Platinum Stainless Steel CT36G/S CT36G/P Natural gas models listed, for LP gas add (-LP) to the model numbers. V E N T I L AT I O N O P T I O N S Burner Rating One 15, 000 Btu/hr (4. 4 kW) burner with 800 Btu/hr (. 2 kW) delivered at simmer One 12, 000 Btu/hr (3. 5 kW) burner with 800 Btu/hr (. 2 kW) delivered at simmer Three 9, 200 Btu/hr (2. 7 kW) burners with 300 Btu/hr (. 1 kW) delivered at simmer Gas Rating Electrical Supply Requirements 54, 600 Btu/hr (16. 0 kW) 120 V AC, 60 Hz 15 amp dedicated circuit 6' (1. 8 m) power cord with 3-prong grounded plug 67 lbs (30 kg) 36" (914) Cooktop or Pro wall hood or liner 36" (914) downdraft ventilation system Power Cord 42" (1067) Cooktop or Pro island hood Shipping Weight For additional information, refer to the Wolf Cooktop Ventilation or Pro Ventilation sections of our website, wolfappliance. com. Specifications are subject to change without notice. ACCESSORIES One-piece wok grate and single burner grate Filler strip High altitude conversion kit Accessories are available through your Wolf dealer. To obtain local dealer information, visit the Locator section of our website, wolfappliance. com. Dimensions in parentheses are in millimeters unless otherwise specified. 3 Planning Information Model CT36G 36" (914) Gas Cooktop I N S TA L L AT I O N S P E C I F I C AT I O N S 13" max (330) 18" 2 1/2"** 19 1/4" (489) (457) (64) COOKTOP CUT-OUT DEPTH 9"*min (229) CUT-OUT TO COMBUSTIBLE MATERIALS (BOTH SIDES) 39" (991) RECOMMENDED CABINET WIDTH 36" min (914) 35" (889) COOKTOP CUT-OUT WIDTH 4" (102) 3 1/2" (89) 3 3/4" min (95) E G 10" (254) 36-INCH OVEN OPENING 2 1/2" min (64) 30" (762) COUNTERTOP TO COMBUSTIBLE MATERIALS ABOVE COOKTOP 24"min (610) 36" (914) STANDARD FLOOR TO COUNTERTOP HEIGHT *Minimum clearance from both side edges of cooktop cut-out to combustible materials up to 18" (457) above countertop. **Minimum clearance from rear edge of cooktop cut-out to combustible materials up to 18" (457) above countertop. 35" (889) COOKTOP CUT-OUT WIDTH 19 1/4" (489) 2 1/2"min (64) COOKTOP CUT-OUT DEPTH FRONT OF COUNTERTOP DIMENSIONS Cooktop Cut-Out Width Recommended Cabinet Width Cooktop Cut-Out Depth Minimum Cabinet Depth Location of Electrical and Gas Supply See Installation Instructions shipped with unit for detailed specifications. [. . . ] For this installation, the electrical and gas supply for the cooktop should be installed in the adjacent cabinet. Refer to page 6 for additional specifications. Be aware of the depth of the cooktop when planning for this installation. IMPORTANT NOTE: Wolf gas cooktops are designed and agency approved for installation with Wolf built-in ovens only. IMPORTANT NOTE: When a oven is installed below the cooktop, unless you are using cabinets deeper than 24" (610), it is recommended that the electrical supply for the oven be placed in an adjacent cabinet within reach of the conduit. A 2" (51) diameter hole to route the conduit through cabinetry will be required. Refer to page 6 for location of electrical supply and additional specifications. When a 36" (914) oven is installed below a cooktop, it is recommended that the rough opening for the oven be 7 3/4" (197) from the floor to ease the use of the oven door. The bottom cabinet support must be able to support 250 lbs (113 kg). Wolf gas cooktops are designed to operate on natural gas at 5" (12. 5 mb) WC (water column) pressure or LP (propane) gas at 10" (25 mb) WC pressure. The minimum line pressure for natural gas is 7" (17. 5 mb) WC and 11" (27. 4 mb) WC for LP gas. The maximum gas supply pressure to the regulator should never exceed 14" (34. 9 mb) WC; . 5 psi (3. 5 kPa). The cooktops are supplied with a 1/2" NPT male gas connection at the right rear bottom corner of the cooktop. The male connector exits the unit straight down and you are supplied with a regulator with two female connectors. Wolf gas cooktops using natural gas function up to an altitude of 8, 000' (2438 m) without any adjustment. Natural gas installations from 8, 000' (2438 m) to 10, 000' (3048 m) need the high altitude conversion kit. LP gas installations will operate up to 10, 000' (3048 m) without adjustment. You must follow all National Electrical Code and gas regulations. In addition, be aware of local codes and ordinances when installing your services. [. . . ] For electrical requirements and additional specifications for the built-in oven, refer to the Built-In Ovens section of our website, wolfappliance. com. 13" max (330) 18" 2 1/2"** 19 1/4" (489) (64) COOKTOP CUT-OUT DEPTH (457) 9"*min (229) CUT-OUT TO COMBUSTIBLE MATERIALS (BOTH SIDES) 39" (991) RECOMMENDED CABINET WIDTH 36" min (914) 35" (889) COOKTOP CUT-OUT WIDTH 3 3/4"min (95) 2 1/2" min (64) 30" (762) COUNTERTOP TO COMBUSTIBLE MATERIALS ABOVE COOKTOP 4" (102) E G 3 1/2" (89) 36" (914) STANDARD FLOOR TO COUNTERTOP HEIGHT 24 1/16" (611) 5" OVEN ELECTRICAL LOCATION WITHIN OPENING APPLIES ONLY TO CABINETS DEEPER THAN 24" (610) (127) E 4" (102) E 10" (254) COOKTOP GAS SUPPLY AND ELECTRICAL LOCATION IN ADJACENT RIGHT SIDE CABINET 24" min (610) 34 1/2" (876) OVEN OPENING WIDTH 7 3/4" (197) rec 4 3/4" (121) min *Minimum clearance from both side edges of cooktop cut-out to combustible materials up to 18" (457) above countertop. **Minimum clearance from rear edge of cooktop cut-out to combustible materials up to 18" (457) above countertop. Unless you are using cabinets deeper than 24" (610), the electrical supply for the oven and the gas and electrical supply for the cooktop should be located in the adjacent right side cabinet as shown. Installation specifications for a 36" (914) gas cooktop installed above a 36" (914) built-in oven. Dimensions in parentheses are in millimeters unless otherwise specified. 6 Planning Information Model CT36G 36" (914) Gas Cooktop I N T E G R AT E D M O D U L E S -- M U LT I P L E U N I T I N S TA L L AT I O N With Wolf's integrated modules, you have the ultimate in customization. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE SUB-ZERO 36GASCOOKTOP

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual SUB-ZERO 36GASCOOKTOP will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag