User manual SUB-ZERO 700 INSTALL GUIDE

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual SUB-ZERO 700 INSTALL GUIDE. We hope that this SUB-ZERO 700 INSTALL GUIDE user guide will be useful to you.

Lastmanuals help download the user guide SUB-ZERO 700 INSTALL GUIDE.


Mode d'emploi SUB-ZERO 700 INSTALL GUIDE
Download
Manual abstract: user guide SUB-ZERO 700 INSTALL GUIDE

Detailed instructions for use are in the User's Guide.

[. . . ] I N T E G R AT E D R E F R I G E R AT I O N INSTALLATION INSTRUCTIONS CONTENTS Installation Recommendations Installation Specifications Installation Instructions Installation Checklist Service Information 3 4 7 18 19 Features and specifications indicated herein and on the website are subject to change at any time without notice. Check our website, subzero. com, for the most up-to-date specifications. As you follow these instructions, you will notice WARNING and CAUTION symbols. This blocked information is important for the safe and efficient installation of Sub-Zero equipment. There are two types of potential hazards that may occur during installation. signals a situation where minor injury or product damage may occur if you do not follow instructions. states a hazard that may cause serious injury or death if precautions are not followed. Another footnote we would like to identify is IMPORTANT NOTE: This highlights information that is especially relevant to a problemfree installation. SUB-ZERO ® is a registered trademark of Sub-Zero Freezer Company, Inc. I N T E G R AT E D I N S TA L L A T I O N R E C O M M E N D A T I O N S I N S TA L L AT I O N R E C O M M E N D AT I O N S The importance of the installation of the Sub-Zero Integrated unit cannot be overemphasized. [. . . ] Once the unit is leveled, secure the unit in place by using the side mounting clips and #8 x 1/2" screws provided. The decorative white molding strips for the side and top of the unit can be snapped into place. The top molding strip used on Integrated tall units, must be installed before the side molding can be attached. The top molding strip is held in place by double-sided velcro fasteners. Refer to illustration 8 below for positioning of the top molding. Illustration 9 shows side molding installation for tall units. Installation of the side molding for base units is the same. For installations where units are side by side, refer to Dual Installations on page 17. NOTE: The molding strips may be painted to match the surrounding cabinetry, if you choose. Follow these easy steps: Rough up the surface to be painted with fine grit sandpaper. Wipe with alcohol to ensure that the surface is clean and dry. Use an appliance or industrial grade, oil base, high gloss enamel paint. To reduce the possibility of the unit tipping forward, the front leveling legs must be in contact with the floor. Top Molding Illus. 9 12 I N T E G R AT E D I N S TA L L A T I O N I N S T R U C T I O N S WAT E R L I N E C O N N E C T I O N Q U I C K C O N N E C T WAT E R VA LV E For units with an ice maker, the quick connect water valve and PEX tubing are located on the right-hand side of the unit towards the bottom. Follow these instructions to connect the ice maker water line. Attach the union fitting to the copper house water supply line. Pull the coiled gray PEX tubing with a red cap and captured metal nut toward the house water supply line. Remove and discard the red cap, then attach the tubing to the union with captured nut. Recoil the excess tubing under the unit. Refer to illustration 10 below. In areas with water of high mineral content, the use of an in-line water filter is recommended. Make sure the filter is positioned and accessible for replacement when necessary. IMPORTANT NOTE: The ice maker will not fill with water immediately. Allow 24 hours for proper ice production. Let your customer know that the first container filled with ice should be discarded, as with any new connection there may be impurities in the ice from the water supply line. Shut power off at the circuit breaker before making electrical connection to the solenoid, if required. IMPORTANT NOTE: Turn on the water supply and check all fittings for leaks. [. . . ] IMPORTANT NOTE: To ensure a safe and proper installation, the following checklist should be completed by the installer to ensure that no part of the installation has been overlooked. Advise the homeowner to fill out and return all product registration forms. This will ensure that the customer information is in our database in the event service is required. Any questions or problems about the installation should be directed to your Sub-Zero dealer or the Sub-Zero Customer Service Department at 800-222-7820. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE SUB-ZERO 700 INSTALL GUIDE

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual SUB-ZERO 700 INSTALL GUIDE will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag