User manual SUB-ZERO DESIGN BROCHURE

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual SUB-ZERO DESIGN. We hope that this SUB-ZERO DESIGN user guide will be useful to you.

Lastmanuals help download the user guide SUB-ZERO DESIGN.


Mode d'emploi SUB-ZERO DESIGN
Download
Manual abstract: user guide SUB-ZERO DESIGNBROCHURE

Detailed instructions for use are in the User's Guide.

[. . . ] SUB-ZERO DESIGN GUIDE Contents Built-In Refrigeration . 92 Features and specifications are subject to change at any time without notice. Visit subzero. com/specs for the most up-to-date information. IMPORTANT NOTE: Throughout this guide, dimensions in parentheses are millimeters unless otherwise specified. MODELS BI-36RG AND BI-36F Built-In Refrigeration 3 subzero. com/specs Built-In Refrigeration. For the built-in line, Sub-Zero designers and engineers took a fresh look at everything, inside and out. [. . . ] · Drawer models are Star-K certified. Integrated Refrigeration 52 Overall Dimensions COLUMN MODELS 27" (686) 14"(356) 24" (610) 27" (686) TALL MODELS 27" (686) 14"(356) 24" (610) 1 5/8" (41) 13/16" (21) 78 9/16" (1995) 78 9/16" (1995) 81" (2057) TO TOP OF OPENNG 3/8" (10) 80" (2032) TO TOP OF OPENNG 1/2" (13) 13 1/4" (337) 10 1/4" (260) 34 1/2" (876) 20 3/8" (518) 9 3/4" (248) 4" (102) 9 3/4" (248) 1/2" (13) ± ADJUSTMENT IN LEVELING LEGS HEIGHT DIMENSIONS ± 1/2" (13) 4" (102) 24" (610) 24" (610) 4 5/8" (117) 4 5/8" (117) 251/2" (648) 191/2" (495) 251/2" (648) DIMENSIONS WILL VARY WITH PANEL THICKNESS DIMENSIONS WILL VARY WITH PANEL THICKNESS MODELS IC-27R AND IC-27FI MODELS 700TR, 700TFI AND 700TCI Overall dimensions do not include panels or handles. Integrated Refrigeration 53 subzero. com/specs Overall Dimensions 36" (914) TALL MODELS 36" (914) 14"(356) 24" (610) 1 5/16" (33) 77 13/16" (1976) 80" 3/8" (10) (2032) TO TOP OF OPENNG 1/2" (13) 13 1/4" (337) 10 1/4" (260) 34 1/2" (876) 20 3/8" (518) 9 3/4" (248) HEIGHT DIMENSIONS ± 1/2" (13) 4" (102) 24" (610) 7" (178) 191/2" (495) 34 1/2" (876) DIMENSIONS WILL VARY WITH PANEL THICKNESS MODELS 736TR, 736TFI AND 736TCI Integrated Refrigeration 54 Overall Dimensions DRAWER MODELS 3/8" (10) Capacity and Weight Interior Capacity COLUMN MODELS R cu ft (L) 16. 2 (459) F cu ft (L) 27" (686) 24" (610) IC-27R IC-27FI 27" (686) TALL MODELS 16. 3 (462) 15. 5 (439) 10. 2 (289) 20. 9 (592) 13. 3 (377) 5. 3 (150) 2. 9 (82) 5. 1 (144) 2. 1 (59) 21. 5 (609) 7. 1 (201) 15. 3 (433) 5. 1 (144) 1/2" (13) 13 1/4" (337) 34 1/2" (876) 700TR 700TFI 700TCI 36" (914) TALL MODELS 10 1/4" (260) 20 3/8" (518) 736TR 736TFI 736TCI 9 3/4" (248) 4" (102) 27" (686) DRAWER MODELS HEIGHT DIMENSIONS ± 1/2" (13) 700BR 700BF(I) 700BC(I) Shipping Weight 24" (610) lbs (kg) 360 (163) 480 (218) 190 (86) IC-27R, IC-27FI, 700TR, 700TFI and 700TCI 736TR, 736TFI and 736TCI 700BR, 700BF(I) and 700BC(I) 191/2" (495) 25 7/8" (657) DIMENSIONS WILL VARY WITH PANEL THICKNESS MODELS 700BR, 700BF(I) AND 700BC(I) Integrated Refrigeration 55 subzero. com/specs Opening Dimensions INTEGRATED MODELS IMPORTANT NOTE: The depth of each integrated model is 24" (610) from the front of the unit to its back. Your design may necessitate moving the unit back or cabinets forward to achieve a flush fit. This will require a minimum rough opening depth of 25" (635). TOP VIEW 25" (635) OPENING DEPTH 25" (635) OPENING DEPTH B OPENING HEIGHT A OPENING WIDTH SIDE VIEW FRONT VIEW Opening Dimensions IC-27R and IC-27FI 700TR, 700TFI, 700TCI 736TR, 736TFI, 736TCI 700BR, 700BF(I), 700BC(I) A 27" (686) 27" (686) 36" (914) 27" (686) B 81" (2057) 80" (2032) 80" (2032) 34 1/2" (876) Integrated Refrigeration 56 Electrical Requirements The electrical supply should be located within the shaded area shown in the illustrations. Follow the National Electrical Code and local codes and ordinances when installing the receptacle. A separate circuit, servicing only this appliance, is required. A ground fault circuit interrupter (GFCI) is not recommended and may cause interruption of operation. IMPORTANT NOTE: It is critical that the electrical outlet be located within the shaded area shown so it does not interfere with installation of the anti-tip bracket. It must be flush with the back wall and positioned with the grounding prong to the right of the thinner blades. Electrical Requirements Power Supply Circuit Breaker Receptacle 115 V AC, 60 Hz 15 amp 3-prong grounding-type LEFT SIDE OF OPENING LEFT SIDE OF OPENING 21/2" (64) 13" (330) 4 1/2" (114) 21/2" (64) 17 1/2" (445) 4 1/2" (114) 1/4" (6) FLOOR FRONT VIEW 1/4" (6) FLOOR FRONT VIEW 27" (686) models. 36" (914) models. Integrated Refrigeration 57 subzero. com/specs Plumbing Requirements For integrated models with an automatic ice maker, the water supply line should be located through the floor or back wall, within the shaded area shown in the illustrations. The water supply line should be connected to the house supply with an easily accessible shut-off valve between the supply and the unit. A saddle valve kit (4200880) is available through your authorized Sub-Zero dealer. IMPORTANT NOTE: It is critical that the water line be located within the shaded area shown so it does not interfere with installation of the anti-tip bracket. 13 1/2" (343) BACK WALL 6" (152) 11/2" (38) 21/2" (64) 13 1/2" (343) 21/2" (64) 3" (76) 3/4" FLOOR FRONT VIEW (19) TOP VIEW An in-line filter is required when water conditions have a high sediment content. The ice maker operates on constant water pressure between 20 psi (1. 4 bar) and 100 psi (6. 9 bar). IMPORTANT NOTE: In some cases, a reverse osmosis water filter system may not be able to maintain the minimum pressure consistently. 36" (914) models. Plumbing Requirements Water Supply Line Water Pressure Excess Water Line for Connection 1/4" OD copper line 20­100 psi (1. 4­6. 9 bar) 27" (686) 9" (229) BACK WALL 6" (152) 11/2" (38) 21/2" (64) 9" (229) 21/2" (64) 3" (76) 3/4" FLOOR FRONT VIEW (19) TOP VIEW 27" (686) models. Integrated Refrigeration 58 Cabinetry Applications FRAMELESS CABINETRY 26 3/4" (679) PANEL WIDTH A A 26 3/4" (679) PANEL WIDTH A 35 3/4" (908) PANEL WIDTH 76 7/8" (1953) 45 3/8" (1153) 45 3/8" (1153) 807/8" (2054) 79 7/8" (2029) 79 7/8" (2029) A A 13 9/16" (345) 13 9/16" (345) A A 34 1/2" (876) 16 11/16" (424) 16 11/16" (424) 4" (102) 27" (686) FINISHED OPENING 4" (102) 27" (686) FINISHED OPENING ALL REVEALS (A) ARE 1/8" (3). 4" (102) 36" (914) FINISHED OPENING COLUMN MODELS 27" (686) MODELS TALL AND DRAWER MODELS 36" (914) MODELS TALL MODELS Typical Panel Dimensions COLUMN MODELS W H Panel dimensions are based on a 1/8" (3) reveal. A reveal of up to 1/4" (6) is possible with adjustments to panel dimensions. Door 27" (686) MODELS 26 3/4" (679) W 76 7/8" (1953) H Door Top Drawer Bottom Drawer 36" (914) MODELS 26 3/4" (679) 26 3/4" (679) 26 3/4" (679) W 45 3/8" (1153) 13 9/16" (345) 16 11/16" (424) H Door Top Drawer Bottom Drawer 35 3/4" (908) 35 3/4" (908) 35 3/4" (908) 45 3/8" (1153) 13 9/16" (345) 16 11/16" (424) Integrated Refrigeration 59 subzero. com/specs Cabinetry Applications DOOR PANEL HEIGHT TOE KICK CLEARANCE The height of the door panel can extend beyond the typical panel height, provided you do not exceed the panel weight limit. The illustration below shows how the panel may be extended and what you need to consider to finish the area behind the door panel. IMPORTANT NOTE: The decorative valance used to finish the area behind the door panel must stay behind the front plane of the finished molding. The toe kick clearance can vary with the height of the panel. You must keep a minimum space of 4" (102) clear below the bottom edge of the panel for proper venting. In addition, any decorative base molding must be removable to clean the condenser and for service. 25" (635) TO WALL 11/2" (38) INTEGRATED UNIT (SIDE VIEW) 1/8"(3) DECORATIVE VALANCE CANNOT EXTEND BEYOND THE FRONT OF THE MOLDING OVERALL HEIGHT DOOR PANEL DECORATIVE VALANCE HEIGHT OF PANEL KICKPLATE/GRILLE CAN BE ADJUSTED FORWARD KICKPLATE/GRILLE 1/8"(3) REMOVABLE MOLDING HINGE BASE MOLDING MUST BE REMOVABLE MINIMUM HEIGHT 4" (102) TO 9" (229) TYPICAL HEIGHT OF DOOR PANEL FROM FLOOR INTEGRATED UNIT (SIDE VIEW) 25" (635) TO WALL 2 5/8" (67) TO 4" (102) UPPER VALANCE COLUMN AND TALL MODELS KICKPLATE / GRILLE AREA ALL INTEGRATED MODELS Integrated Refrigeration 60 Cabinetry Applications Integrated refrigeration is compatible with virtually any style and look of cabinetry. These models can be used with framed as well as frameless cabinetry. Because of the precise application and the look you may want to achieve, keep the following considerations in mind: The thickness of the front panels can vary. A minimum (16) thick panel is required, but the thickness can be increased provided the panel weight limit is not exceeded. 5/8" IMPORTANT NOTE: The inside edges of the rough opening as well as the sides and a portion of the backside of the decorative panels will need to be finished, as they will be exposed when the doors are open. D-style handles are recommended. For the cabinet door, handles must be located near the edge of the panel opposite the hinge, centered top to bottom. Locate handles in the top center area of the drawer panels. Illustrations on the following pages show typical applications of frameless and framed cabinetry. Also refer to the full-scale illustration at the end of this section for specifics on door openings. IMPORTANT NOTE: The depth of each integrated model is 24" (610) from the front of the unit to its back. You must allow for the thickness of the panel you are applying when planning for the finished rough opening depth if you want the front panel to be flush with surrounding cabinetry. [. . . ] Service will be provided in the home during the normal business hours. This warranty applies only to products installed for normal residential use. Details regarding a non-residential warranty are available upon request. The warranty applies only to products installed in any one of the fifty states of the United States, the District of Columbia or the ten provinces of Canada. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE SUB-ZERO DESIGN

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual SUB-ZERO DESIGN will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag