User manual SUB-ZERO DUALFUEL INSTALL GUIDE

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual SUB-ZERO DUALFUEL INSTALL GUIDE. We hope that this SUB-ZERO DUALFUEL INSTALL GUIDE user guide will be useful to you.

Lastmanuals help download the user guide SUB-ZERO DUALFUEL INSTALL GUIDE.


Mode d'emploi SUB-ZERO DUALFUEL INSTALL GUIDE
Download
Manual abstract: user guide SUB-ZERO DUALFUEL INSTALL GUIDE

Detailed instructions for use are in the User's Guide.

[. . . ] D UAL F UEL R ANGES INSTALLATION INSTRUCTIONS As you follow these instructions, you will notice WARNING and CAUTION symbols. This blocked information is important for the safe and efficient installation of Wolf equipment. There are two types of potential hazards that may occur during installation. signals a situation where minor injury or product damage may occur if you do not follow instructions. states a hazard that may cause serious injury or death if precautions are not followed. Another footnote we would like to identify is IMPORTANT NOTE: This highlights information that is especially relevant to a problemfree installation. WOLF ® is a registered trademark of Wolf Appliance Company, LLC W O L F D UA L F U E L R A N G E S I N S TA L L AT I O N R E Q U I R E M E N T S IMPORTANT NOTE: This installation must be completed by a qualified installer, service agency or gas supplier. IMPORTANT NOTE: Save these Installation Instructions for the local inspector's use. [. . . ] 12 Spring hinge locations for 48" (1219) and 60" (1524) ranges. Oven door removal I N S TA L L AT I O N I N S T R U C T I O N S G A S S U P P LY R E Q U I R E M E N T S Provide a gas supply line of 3/4" rigid pipe to the range location. A smaller size pipe on long runs may result in insufficient gas supply. Pipe joint compounds, suitable for use with LP gas should be used. For LP gas, piping or tubing size can be 1/2" minimum. LP gas suppliers usually determine the size and materials used on the system. If local codes permit, a new CSA design certified, 3' (. 9 m) long, 1/2" or 3/4" ID flexible metal appliance connector is recommended for connecting this range to the gas supply line. Do not kink or damage the flexible connector when moving the range. The pipe coming out the bottom of the unit has 1/2" male threads. You will need to determine the fittings required, depending on the size of your gas supply line, flexible metal connector and shut-off valve. If rigid pipe is used as a gas supply line, a combination of pipe fittings must be used to obtain an in-line connection to the range. All strains must be removed from the supply and gas lines so the range will be level and in line. IMPORTANT NOTE: The supply line must be equipped with an approved external gas shut-off valve located near the range in an accessible location. Do not block access to the shut-off valve. Refer to the illustration below. EXPLOSION HAZARD -- Use a new CSA approved gas supply line and install a gas shut-off valve. For LP gas, have a qualified technician make sure the gas pressure does not exceed 14" (34. 9 mb) WC (water column). Failure to do so can result in explosion, fire or death. I M P O R TA N T N OT E This installation must conform with local codes and ordinances. In the absence of local codes, installations must conform with the American National Standard, National Fuel Gas Code. IMPORTANT NOTE: The dual fuel range must be connected to a regulated gas supply. IMPORTANT NOTE: This installation must conform with local codes and ordinances. In the absence of local codes, installations must conform with American National Standard, National Fuel Gas Code ANSI Z223. 1 ­ latest edition or CANI ­ B149. 1 or 2. The range is equipped for use with natural or LP gas. It is design certified by the Canadian Standards Association (CSA) for natural or LP gases. The rating plate, located at the far right of the bottom of the control panel assembly just above the oven door, has information on the type of gas that should be used. [. . . ] After setting the time, the hidden control panel can be closed. The control panel does not have to be open to operate the oven. Select any of the eight cooking modes by using the oven control knob bezel and turning to the desired mode. Once the mode has been selected, the temperature can be adjusted by turning the temperature readout knob clockwise to increase the temperature or counterclockwise to decrease the temperature. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE SUB-ZERO DUALFUEL INSTALL GUIDE

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual SUB-ZERO DUALFUEL INSTALL GUIDE will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag