User manual SUB-ZERO ELECTRICCT INSTALL GUIDE

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual SUB-ZERO ELECTRICCT INSTALL GUIDE. We hope that this SUB-ZERO ELECTRICCT INSTALL GUIDE user guide will be useful to you.

Lastmanuals help download the user guide SUB-ZERO ELECTRICCT INSTALL GUIDE.


Mode d'emploi SUB-ZERO ELECTRICCT INSTALL GUIDE
Download
Manual abstract: user guide SUB-ZERO ELECTRICCT INSTALL GUIDE

Detailed instructions for use are in the User's Guide.

[. . . ] E LECTRIC C OOKTOPS INSTALLATION INSTRUCTIONS As you follow these instructions, you will notice WARNING and CAUTION symbols. This blocked information is important for the safe and efficient installation of Wolf equipment. There are two types of potential hazards that may occur during installation. signals a situation where minor injury or product damage may occur if you do not follow instructions. states a hazard that may cause serious injury or death if precautions are not followed. Another footnote we would like to identify is IMPORTANT NOTE: This highlights information that is especially relevant to a problemfree installation. WOLF ® is a registered trademark of Wolf Appliance Company, LLC W O L F E L E C T R I C C O O K TO P S I N S TA L L AT I O N R E Q U I R E M E N T S B E F O R E YO U S TA RT IMPORTANT NOTE: Save these Installation Instructions for the local inspector's use. Please read the entire Installation Instructions prior to installation. [. . . ] IMPORTANT NOTE: Unframed electric cooktop Model CT36EU is not designed to be installed in combination with other cooktops. IMPORTANT NOTE: Unframed electric cooktops cannot be installed with a downdraft ventilation system. For Model CT36EU installation options, refer to Unframed Installations on pages 10­11. I N S TA L L A T I O N S P E C I F I C A T I O N S ­ M O D E L C T 3 6 E U 21" (533) OVERALL DEPTH 36" (914) OVERALL WIDTH 13" max (330) SEE COUNTERTOP CUT-OUT BELOW 24" OR 30"* (610 or 762) TO COUNTERTOP 18" (457) 39" (991) RECOMMENDED CABINET WIDTH SEE COUNTERTOP CUT-OUT BELOW 18" (457) 4" (102) 2"** (51) 2"** (51) 4" min (102) 4" (102) 3 1/2" (89) E 10" (254) 36-INCH OVEN OPENING Overall Dimensions 24"min (610) MODEL CT36EU Overall Width Overall Height Overall Depth 36" (914) 4" (102) 21" (533) 36" (914) STANDARD FLOOR TO COUNTERTOP HEIGHT Minimum Cabinet Depth 22 3/4" (578) Minimum Height Clearance* 4" (102) Cut-Out Width Cut-Out Depth 34 3/8" (873) 19 3/8" (492) *Minimum 24" (610) from protected cabinet or 30" (762) from unprotected cabinet to countertop. **Minimum clearance from side edge of cooktop cut-out to combustible surface up to 18" (457) above countertop. Countertop Cut-Out RECESSED AREA FOR FLUSH MOUNT INSTALLATION ONLY COUNTERTOP PROFILE 7/8" (22) max 1 5/16" (49) RADIUS 36 1/8"* (918) RECESSED AREA FOR FLUSH MOUNT INSTALLATION ONLY 34 3/8" (873) COOKTOP CUT-OUT WIDTH *Minimum 6" (152) clearance is required between countertop and any combustible surface directly below the cooktop. Dimensions may vary to ± 1/8" (3). 21 1/8"* (537) RECESSED AREA FOR FLUSH MOUNT INSTALLATION ONLY 5/16"(24) 7/16" (11) RADIUS 19 3/8" (492) COOKTOP CUT-OUT DEPTH 1 9/16" (40) FRONT OF COUNTERTOP Dimensions in parentheses are in millimeters unless otherwise specified. *Minimum dimension, but may be exceeded by up to 1/8" (3). 2 7/16" (62) 9 W O L F E L E C T R I C C O O K TO P S U N F R A M E D I N S TA L L A T I O N S F L U S H M O U N T I N S TA L L AT I O N Flush mount installations are intended for granite, solid surface or stone countertop surfaces only. Failure to use high heat resistant surface will result in countertop damage if hot cooking utensils are accidentally moved off the cooking surface. There are two options for a flush mount installation of the unframed electric cooktop; Option 1 and Option 2. OPTION 1: For this flush mount installation, a recessed area surrounding the standard countertop cut-out is required. Fabrication of the recessed area must take place before the final countertop installation. A template of the countertop cut-out is provided with the unframed cooktop for fabrication purposes. IMPORTANT NOTE: This fabrication method is not recommended for molded backsplash style countertops (triple cove). For countertop cut-out dimensions, refer to the Installation Specifications illustration on page 8 for Model CT30EU and page 9 for Model CT36EU. In order to rout the required recessed area for this flush mount installation, a second template must be made from 1/2" (13) plywood. The template will be used as a guide for a top bearing router bit. Make the wood template wide enough so that clamps used to hold this template to the countertop do not interfere with the router base. The cut-out dimension of the wood template should match the outer perimeter of the template supplied with the cooktop. Center the wood template over the existing cut-out in the countertop and clamp. It may be helpful to use medium-strength double-sided tape to adhere the template to the countertop; this will keep the template from shifting during the routing operation. Make sure that the adhesive can be easily removed by testing it on a scrap piece of the countertop. Using a top bearing router bit with the wood template as a guide, rout out a 5/16" (8) deep recessed area in the countertop cut-out. MODELS CT30EU AND CT36EU Unframed electric cooktop Models CT30EU and CT36EU can be mounted flush with the top of the countertop or as a frameless installation with the glass mounted on top of the countertop surface. IMPORTANT NOTE: The materials required for a flush mount installation are provided with the unframed Models CT30EU and CT36EU. Refer to the instructions provided with the unframed cooktop installation package (part #806299) for additional specifications. 10 Dimensions in parentheses are in millimeters unless otherwise specified. I N S TA L L AT I O N I N S T R U C T I O N S U N F R A M E D I N S TA L L A T I O N S F L U S H M O U N T I N S TA L L A T I O N OPTION 2: For this flush mount installation, the countertop cut-out will be the same size as the outer edge of the glass top. It is recommended that cooktop itself be used as the template for the cut-out. [. . . ] IMPORTANT NOTE: Do not seal the cooktop to the countertop. It must be removed if service is necessary. Clean the glass ceramic surface carefully using the Cooktop Cleaning Crème provided with the cooktop. Read the entire Wolf Electric Cooktops Use & Care Information included with the cooktop. Important safety, service and warranty information is contained within the book. C O O K T O P R E M OVA L IMPORTANT NOTE: This procedure should only be performed by a Wolf authorized service center. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE SUB-ZERO ELECTRICCT INSTALL GUIDE

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual SUB-ZERO ELECTRICCT INSTALL GUIDE will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag