User manual SUB-ZERO GASCT INSTALL GUIDE

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual SUB-ZERO GASCT INSTALL GUIDE. We hope that this SUB-ZERO GASCT INSTALL GUIDE user guide will be useful to you.

Lastmanuals help download the user guide SUB-ZERO GASCT INSTALL GUIDE.


Mode d'emploi SUB-ZERO GASCT INSTALL GUIDE
Download
Manual abstract: user guide SUB-ZERO GASCT INSTALL GUIDE

Detailed instructions for use are in the User's Guide.

[. . . ] G AS C OOKTOPS INSTALLATION INSTRUCTIONS As you follow these instructions, you will notice WARNING and CAUTION symbols. This blocked information is important for the safe and efficient installation of Wolf equipment. There are two types of potential hazards that may occur during installation. signals a situation where minor injury or product damage may occur if you do not follow instructions. states a hazard that may cause serious injury or death if precautions are not followed. Another footnote we would like to identify is IMPORTANT NOTE: This highlights information that is especially relevant to a problemfree installation. WOLF ® is a registered trademark of Wolf Appliance Company, Inc. W O L F G A S C O O K TO P S I N S TA L L AT I O N R E Q U I R E M E N T S IMPORTANT NOTE: This installation must be completed by a qualified installer, service agency or gas supplier. IMPORTANT NOTE: Save these Installation Instructions for the local inspector's use. [. . . ] Failure to do so can result in explosion, fire or death. If local codes permit, a new CSA designcertified, 4­5' (1. 2­1. 5 m) long, 1/2" or 3/4" ID, flexible metal appliance connector is recommended for connecting this cooktop to the gas supply line. Do not kink or damage the flexible connector when moving the cooktop. The pressure regulator has 1/2" female pipe threads. You will need to determine the fittings required, depending on the size of your gas supply line, flexible metal connector and shutoff valve. If rigid pipe is used as a gas supply line, a combination of pipe fittings must be used to obtain an in-line connection to the cooktop. All strains must be removed from the supply and gas lines so the cooktop will be level and in line. IMPORTANT NOTE: The supply line must be equipped with an approved external gas shut-off valve located near the cooktop in an accessible location. Do not block access to the shut-off valve. The inlet pressure to the regulator should be as follows for operation and checking the regulator setting: Natural Gas: Set pressure 5" (12. 5 mb) WC, supply pressure 7­14" (17. 5­34. 9 mb) max. LP Gas: Set pressure 10" (25 mb) WC, supply pressure 11­14" (27. 4­34. 9 mb) WC. IMPORTANT NOTE: The gas cooktop must be connected to a regulated gas supply. IMPORTANT NOTE: This installation must conform with local codes and ordinances. In the absence of local codes, installations must conform with American National Standard, National Fuel Gas Code ANSI Z223. 1 ­ latest edition or CANI ­ B149. 1 or 2. IMPORTANT NOTE: The natural gas cooktop is rated for elevations up to 8, 000' (2438 m) without adjustment. Install a high altitude kit for elevations from 8, 000' (2438 m) to 10, 000' (3084 m). The LP gas cooktop is rated for 10, 000' (3084 m). The cooktop is equipped for use with natural or LP gas. It is design certified by the Canadian Standards Association (CSA) for natural or LP gases. The rating plate, located on the underside of the burner box, has information on the type of gas that should be used. If this information does not agree with the type of gas available, check with the local gas supplier. Provide a gas supply line of 3/4" rigid pipe to the cooktop location. A smaller size pipe on long runs may result in insufficient gas supply. Pipe joint compounds, suitable for use with LP gas should be used. [. . . ] Be sure to place the burner heads and caps on each burner base and position the burner grates over the burner bases and heads before lighting. To check operation of the surface burners, push in and turn each control knob to the HIGH position. The flame should light within four seconds. If the burners do not light properly, turn control knob to the OFF position. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE SUB-ZERO GASCT INSTALL GUIDE

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual SUB-ZERO GASCT INSTALL GUIDE will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag