User manual SUB-ZERO IF15

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual SUB-ZERO IF15. We hope that this SUB-ZERO IF15 user guide will be useful to you.

Lastmanuals help download the user guide SUB-ZERO IF15.


Mode d'emploi SUB-ZERO IF15
Download
Manual abstract: user guide SUB-ZERO IF15

Detailed instructions for use are in the User's Guide.

[. . . ] In addition, the extremely deep fryer will enable you to handle large portions of small items or a whole chicken. Let Wolf, the corporate companion and kitchen soul mate of Sub-Zero, fuel your passion for cooking and kitchen design. Dimensions in parentheses are in millimeters unless otherwise specified. 7/06 1 Planning Information Integrated Electric Fryer Module MODEL IF15/S F E AT U R E S Integrated design allows for installation of multiple cooktops or modules Stainless steel top construction with classic stainless steel finish Hidden 2600 -watt heating element Illuminated electronic touch controls with graduated control lighting Large 11/4 gallon (3. 8 L) capacity tub Three baskets included--one large and two small side by side, each with wire basket hanger Low-profile lid Melt feature for shortening or lard Independent digital timer Digital temperature readout and preheat indicator Easy manual locking drain capability CSA certified for US and Canada Two and five year residential warranty ­ exclusions apply; warranty information can be found on our website, wolfappliance. com OVERALL DIMENSIONS 21" (533) OVERALL DEPTH 15" (381) OVERALL WIDTH 7 1/2" (191) 131/2" (343) TO DRAIN OUTLET Dimensions may vary by ± 1/8" (3). [. . . ] An 18" (457) wide cabinet is recommended for installation of a single 15" (381) cooktop or module. IMPORTANT NOTE: Review specific installation instructions for product to product capabilities When multiple cooktops or modules are installed side by side, refer to the countertop cut-out dimensions on page 6. IMPORTANT NOTE: Wolf does not recommend the use of downdraft ventilation with the integrated fryer module. The Wolf integrated fryer module requires a separate, grounded 3-wire 240/208 V AC, 60 Hz, 15 amp service with its own circuit breaker. The unit is provided with a 4' (1. 2 m) flexible 3-wire conduit for connection at the electrical supply. Locate electrical within the shaded area shown in the Installation illustration on page 4. You must follow all National Electrical Code regulations. In addition, be aware of local codes and ordinances when installing your service. The integrated fryer module must be installed in a base cabinet with access to the bottom of the unit to drain the oil through a manual valve. The consumer must supply a heat resistant bucket to accept the drained oil. Refer to the Installation illustration on page 4 for location of the drain outlet. Refer to the installation instructions shipped with each Wolf product for detailed specifications. This fryer module must be installed at least 15" (381) away from any open flame cooking device. The open flame may cause ignition of oil. This fryer module must be installed at least 15" (381) away from a Wolf steamer module, as contact between water and hot oil may cause burns from steam and hot oil. This cooktop is intended for indoor use only. A Wolf Cooktop or Pro ventilation hood is recommended. When installing a ventilation hood, refer to the specific requirements of the hood for the minimum dimension to countertop. Also refer to Ventilation Recommendations in the Cooktop Ventilation or Pro Ventilation sections of our website, wolfappliance. com. Dimensions in parentheses are in millimeters unless otherwise specified. 5 Planning Information Integrated Electric Fryer Module MODEL IF15/S I N T E G R AT E D M O D U L E S -- M U LT I P L E U N I T I N S TA L L AT I O N With Wolf's integrated modules, you have the ultimate in customization. [. . . ] However, each unit must have its own regulator installed between the mainline and the cooktop or module. When two or more cooktops or modules are installed together, an integrated module filler strip is recommended. Contact your Wolf dealer for information on this accessory component. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE SUB-ZERO IF15

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual SUB-ZERO IF15 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag