User manual SUB-ZERO INTERNATIONAL DESIGN BROCHURE

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual SUB-ZERO INTERNATIONAL DESIGN. We hope that this SUB-ZERO INTERNATIONAL DESIGN user guide will be useful to you.

Lastmanuals help download the user guide SUB-ZERO INTERNATIONAL DESIGN.


Mode d'emploi SUB-ZERO INTERNATIONAL DESIGN
Download
Manual abstract: user guide SUB-ZERO INTERNATIONAL DESIGNBROCHURE

Detailed instructions for use are in the User's Guide.

[. . . ] INTERNATIONAL DESIGN GUIDE CONTENTS Built-In Refrigeration Integrated Refrigeration Wine Storage Undercounter Refrigeration 4 27 46 63 Features and specifications indicated herein and on our website are subject to change at any time without notice. Check our website, subzero. com, for the most up-to-date specifications. IMPORTANT NOTE International models from the factory designed without a transformer require a 220/240 V AC, 50/60 Hz electrical supply, fused at the correct rating for the unit. If required by local or national codes, the power cord can be easily replaced using the power inlet device. International models using a factory installed transformer require a 220/240 V AC, 50/60 Hz electrical supply, fused at the correct rating for the unit. [. . . ] The outlet must be flush with the back wall. Refer to the Installation Specifications illustration for your model for exact placement. IMPORTANT NOTE: A ground fault circuit interrupter (GFCI) is not recommended and may cause interruption of operation. 32 OVERALL DIMENSIONS Models I700TR, I700TFI and I700TCI 686 mm (UNIT DIMENSION) 356 mm 21 mm TOP OF ROUGH OPENING 610 mm (UNIT DIMENSION) A L L R E F R I G E R AT O R ALL FREEZER 610 mm DOOR MOUNTING DETAIL DOOR/ DRAWER CLOSED DOOR/ DRAWER CLOSED Model I700TR All Refrigerator Model I700TFI All Freezer with Ice Maker 2032 mm* 90° 10 mm 1995 mm* 648 mm* 495 mm* 105° OVER-AND-UNDER Refrigerator | Freezer 657 mm 337 13 mm mm DRAWER MOUNTING DETAIL 117 mm* 90° DOOR OPENING 876 mm* MAXIMUM DOOR OPENING Model I700TCI with Ice Maker TOP VIEW *DOOR/DRAWER PANEL THICKNESS NOT INCLUDED ­ DIMENSION WILL VARY WITH INSTALLATION 260 mm 518 mm 248 mm 102 mm FRONT VIEW _ *13 mm + ADJUSTMENT IN LEVELING LEGS SIDE VIEW I N S TA L L AT I O N S P E C I F I C AT I O N S Models I700TR, I700TFI and I700TCI 38 mm 635 mm TOP VIEW ANTI-TIP BRACKET* TOP VIEW 152 mm 343 mm 229 mm 686 mm MODEL I700TR MODEL I700TFI MODEL I700TCI Overall Dimensions Width Height Depth 686 mm 2032 mm 610 mm 343 mm 394 mm ANTI-TIP BRACKET Models without an ice maker will not require the water line connection. 686 mm WATER LINE SIDE ENTRY LOCATIONS WATER LINE BOTTOM ENTRY LOCATION *PLACEMENT OF THE ANTI-TIP BRACKET SHOULD BE 610 mm FROM THE FRONT OF THE UNIT WITHOUT PANELS TO THE BACK OF THE ANTI-TIP BRACKET. 38 mm 38 mm Finished Opening Width Height 686 mm 2032 mm 635 mm* 686 mm 635 mm Depth LOCATE ELECTRICAL WITHIN SHADED AREA ­ ORIENT GROUND PRONG TO RIGHT AS SHOWN ANTI-TIP BRACKET LOCATE WATER LINE (REAR ENTRY) WITHIN SHADED AREA 2032 mm 114 mm 330 mm 64 mm 394 mm 229 mm *The depth of the unit is 610 mm from the front of the unit to its back. Your design may necessitate moving the unit back or cabinets forward to achieve a flush fit. This will require a minimum rough opening depth of 635 mm. 76 mm 6 mm 19 mm NOTE: ANTI-TIP BRACKET MUST BE INSTALLED TO PREVENT UNIT FROM TIPPING FORWARD ANTI-TIP BRACKET WATER LINE SIDE ENTRY LOCATION FRONT VIEW SIDE VIEW 33 OVERALL DIMENSIONS Models I736TR and I736TCI 914 mm (UNIT DIMENSION) 356 mm TOP OF ROUGH OPENING 610 mm (UNIT DIMENSION) A L L R E F R I G E R AT O R 33 mm Model I736TR All Refrigerator DOOR MOUNTING DETAIL DOOR/DRAWER CLOSED 610 mm DOOR/DRAWER CLOSED OVER-AND-UNDER Refrigerator | Freezer 2032 mm* 90° Model I736TCI with Ice Maker 10 mm 1976 mm* 495 876 mm* mm* 105° 886 mm 337 13 mm mm DRAWER MOUNTING DETAIL 90° DOOR OPENING 876 mm* MAXIMUM DOOR OPENING TOP VIEW *DOOR/DRAWER PANEL THICKNESS NOT INCLUDED ­ DIMENSION WILL VARY WITH INSTALLATION 178 mm* 260 mm 518 mm 248 mm 102 mm FRONT VIEW _ *13 mm + ADJUSTMENT IN LEVELING LEGS SIDE VIEW MODEL I736TR MODEL I736TCI Overall Dimensions Width Height Depth 914 mm 2032 mm 610 mm I N S TA L L AT I O N S P E C I F I C AT I O N S Models I736TR and I736TCI 38 mm 635 mm TOP VIEW ANTI-TIP BRACKET* TOP VIEW 152 mm 457 mm 343 mm WATER LINE BOTTOM ENTRY LOCATION 457 mm 508 mm 686 mm ANTI-TIP BRACKET Models without an ice maker will not require the water line connection. 686 mm WATER LINE SIDE ENTRY LOCATIONS Finished Opening Width Height Depth 914 mm 2032 mm 635 mm* *PLACEMENT OF THE ANTI-TIP BRACKET SHOULD BE 610 mm FROM THE FRONT OF THE UNIT WITHOUT PANELS TO THE BACK OF THE ANTI-TIP BRACKET. 38 mm 38 mm 914 mm 635 mm *The depth of the unit is 610 mm from the front of the unit to its back. Your design may necessitate moving the unit back or cabinets forward to achieve a flush fit. This will require a minimum rough opening depth of 635 mm. 114 mm LOCATE ELECTRICAL WITHIN SHADED AREA ­ ORIENT GROUND PRONG TO RIGHT AS SHOWN ANTI-TIP BRACKET LOCATE WATER LINE (REAR ENTRY) WITHIN SHADED AREA 2032 mm 76 mm 6 mm 445 mm 64 mm 508 mm 343 mm 19 mm NOTE: ANTI-TIP BRACKET MUST BE INSTALLED TO PREVENT UNIT FROM TIPPING FORWARD ANTI-TIP BRACKET WATER LINE SIDE ENTRY LOCATION 34 FRONT VIEW SIDE VIEW OVERALL DIMENSIONS Models I700BR, I700BFI and I700BCI 686 mm 10 mm (UNIT DIMENSION) 610 mm (UNIT DIMENSION) DRAWERS 337 13 mm mm DRAWER MOUNTING DETAIL 610 mm 876 mm* Model I700BR All Refrigerator DRAWER CLOSED 260 mm 518 mm Model I700BFI All Freezer with Ice Maker Model I700BCI Refrigerator | Freezer with Ice Maker 248 mm 495 mm* 102 mm FRONT VIEW _ *13 mm + ADJUSTMENT IN LEVELING LEGS SIDE VIEW 657 mm TOP VIEW *DRAWER PANEL THICKNESS NOT INCLUDED I N S TA L L AT I O N S P E C I F I C AT I O N S Models I700BR, I700BFI and I700BCI Models without an ice maker will not require the water line connection. 38 mm 635 mm TOP VIEW ANTI-TIP BRACKET* TOP VIEW MODEL I700BR MODEL I700BFI MODEL I700BCI Overall Dimensions 686 mm 152 mm 343 mm 229 mm 686 mm 343 mm 394 mm ANTI-TIP BRACKET Width Height Depth 686 mm 876 mm 610 mm WATER LINE BOTTOM ENTRY LOCATION *PLACEMENT OF THE ANTI-TIP BRACKET SHOULD BE 610 mm FROM THE FRONT OF THE UNIT WITHOUT PANELS TO THE BACK OF THE ANTI-TIP BRACKET. WATER LINE SIDE ENTRY LOCATIONS Finished Opening 38 mm 38 mm Width Height Depth 686 mm 876 mm 635 mm* 686 mm 635 mm 876 mm WATER LINE SIDE ENTRY LOCATION NOTE: ANTI-TIP BRACKET MUST BE INSTALLED TO PREVENT UNIT FROM TIPPING FORWARD ANTI-TIP BRACKET FRONT VIEW LOCATE ELECTRICAL WITHIN SHADED AREA ­ ORIENT GROUND PRONG TO RIGHT AS SHOWN ANTI-TIP BRACKET LOCATE WATER LINE (REAR ENTRY) WITHIN SHADED AREA SIDE VIEW *The depth of the unit is 610 mm from the front of the unit to its back. Your design may necessitate moving the unit back or cabinets forward to achieve a flush fit. This will require a minimum rough opening depth of 635 mm. I N S TA L L AT I O N Refer to the installation instructions shipped with each Sub-Zero product for detailed specifications. 114 mm 6 mm 330 mm 64 mm 394 mm 229 mm 76 mm 19 mm 35 CABINETRY APPLICATIONS Integrated refrigeration is compatible with virtually any style and look of cabinetry. The models can be used with framed as well as frameless cabinets. Because of the precise application and the look you may want to achieve, there are important questions you need to answer before ordering panels for the doors/drawers. As you look at styles of cabinets, keep some important facts in mind: PANEL REQUIREMENTS Door and drawer panels must be a minimum of 16 mm thick. The door panel cannot exceed 18 kg and each drawer panel must not exceed 5 kg for 686 mm wide units. For 914 mm wide units, the door panel weight limit is 24 kg and 7 kg for each drawer panel. FRAMED CABINETRY Framed cabinetry applications present you with different questions to address. The illustrations below show common applications of framed cabinetry. These are not meant to be the only alternatives, but are suggestions from designers around the country. Also refer to the full-scale illustrations at the end of this section for specifics on door openings. NOTE: In the illustrations below, the first width dimension shown is for 686 mm wide units and the second dimension is for 914 mm wide units. IMPORTANT NOTE: The depth of each Integrated model is 610 mm from the front of the unit to its back. You must allow for the thickness of the panel you are applying when planning for the finished rough opening depth if you want the front panel to be flush with surrounding cabinetry. You must move the unit back into drywall or bring the cabinets forward to achieve a flush fit. The height of the door panel can grow beyond 1153 mm and exceed the 2032 mm overall height as long as you stay below the recommended door panel weight limit. The toe kick clearance can vary with the height of the lower drawer panel; the maximum panel height is 424 mm. [. . . ] An air gap will likely be required between the ice maker drain tube and the drain/waste receptacle. A stand pipe with a trap below it would be acceptable for the drain/waste receptacle. Refer to the illustrations below. I N S TA L L AT I O N Refer to the installation instructions shipped with each Sub-Zero product for detailed specifications. DOOR PANEL ­ MODEL 315IP It is important to understand the differences in mounting any wood panel to the Model 315IP . Refer to the installation instructions packaged with the unit to understand how the panel is installed. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE SUB-ZERO INTERNATIONAL DESIGN

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual SUB-ZERO INTERNATIONAL DESIGN will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag