User manual SUB-ZERO L462212

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual SUB-ZERO L462212. We hope that this SUB-ZERO L462212 user guide will be useful to you.

Lastmanuals help download the user guide SUB-ZERO L462212.


Mode d'emploi SUB-ZERO L462212
Download
Manual abstract: user guide SUB-ZERO L462212

Detailed instructions for use are in the User's Guide.

[. . . ] All you have to do is decide what it will look like. Sometimes referred to as power packs, these liners bring all of the controls, lighting and convenience of our new ventilation line for those applications with a custom exterior treatment. Pro ventilation hood liners are recommended for use with all Wolf cooking appliances. This Pro liner will accommodate a 48" (1219) wide decorative hood. Dimensions in parentheses are in millimeters unless otherwise specified. [. . . ] Locate electrical within the shaded area shown in the Installation illustration on page 4. You must follow all National Electrical Code regulations. In addition, be aware of local codes and ordinances when installing your service. A decorative hood can be created out of wood, plaster, tile or metal. The shape of the decorative hood is not critical, the only place where the the liner and outside cover must meet is at the bottom edge of the metal liner. The decorative hood and liner must fit at the bottom edge in both width and depth. The height of the liner does not have to be the same as the height of the decorative hood, and is generally shorter. The top depth of the liner, 12" (305) standard, must be less than the interior depth of the decorative hood. Measure the interior depth of the hood at the top height of the liner to make sure the liner will fit inside of the decorative hood. The hood liner comes standard with a 4" (102) lower reveal. Be sure to include this dimension in your decorative hood selection. Always use the interior measurements of the decorative hood and measure in multiple places. Use the smallest dimensions to verify hood liner specifications. Refer to the installation instructions shipped with each Wolf product for detailed specifications. This information can also be found on our website, wolfappliance. com. Dimensions in parentheses are in millimeters unless otherwise specified. 5 Planning Information Model L462212 Pro Hood Liner D U C T I N G C O N S I D E R AT I O N S Model L282212I comes with an internal blower, all other Wolf Pro hood liners are shipped without the blower assembly. Internal, in-line or remote blower assemblies are available. For hood liners, the remote blower can be mounted on the roof or exterior wall. Pro hood liners have a vertical discharge location as shown in the illustration below. IMPORTANT NOTE: Install these hood liners only with a Wolf blower. Refer to the Pro ventilation charts at the end of this section for recommendations and blower options. Ducting considerations for Pro hood liners. DUCTWORK INSTALLATION THROUGH ROOF ROOF CAP OR REMOTE BLOWER ­ TRANSITION FROM 8" (203) TO 10" (254) DUCT REQUIRED FOR REMOTE BLOWER 8" ROUND DUCT (L282212I) 10" ROUND DUCT (ALL OTHER LINERS) TRANSITION 17 3/4"W x 4 1/4"D TO 8" ROUND 9 3/8"H (L282212I) 22 1/4"W x 9"D TO 10" ROUND 10"H (ALL OTHER LINERS) DIMENSIONS INCLUDE FLANGES VERTICAL DISCHARGE SOFIT OR CABINET OR DUCT COVER DECORATIVE HOOD 12" (305) HEIGHT OF LINER HOOD LINER 221/2" (572) DEPTH OF LINER 30" TO 36" (762­914) COUNTERTOP TO BOTTOM OF DECORATIVE HOOD 36" (914) STANDARD FLOOR TO COUNTERTOP HEIGHT VERTICAL DISCHARGE ONLY FOR VENTILATION HOOD LINERS. Dimensions in parentheses are in millimeters unless otherwise specified. 6 Planning Information Wolf Ventilation Recommendations WOLF BLOWER ASSEMBLIES A ventilation system must include a blower assembly. With a few exceptions where internal blowers are included, Wolf ventilation hoods and downdrafts are shipped without the blower assembly. An internal, in-line or remote blower assembly must be selected to accommodate the cooking appliance, CFM requirements and homeowner preferences. [. . . ] In-line blower is vertical discharge with 10" (254) round duct. Remote blowers are adjustable discharge with 10" (254) round duct. Transition with backdraft damper included with hood liners. Blower configurations are for reference only. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE SUB-ZERO L462212

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual SUB-ZERO L462212 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag