Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual SUB-ZERO PROLINER INSTALL GUIDE. We hope that this SUB-ZERO PROLINER INSTALL GUIDE user guide will be useful to you.
Lastmanuals help download the user guide SUB-ZERO PROLINER INSTALL GUIDE.
Manual abstract: user guide SUB-ZERO PROLINER INSTALL GUIDE
Detailed instructions for use are in the User's Guide.
[. . . ] P R O V E N T I L AT I O N H O O D L I N E R S
INSTALLATION INSTRUCTIONS
C O N TA C T I N F O R M AT I O N
Wolf Customer Service: 800-332-9513 Website: wolfappliance. com
As you follow these instructions, you will notice WARNING and CAUTION symbols. This blocked information is important for the safe and efficient installation of Wolf equipment. There are two types of potential hazards that may occur during installation.
signals a situation where minor injury or product damage may occur if you do not follow instructions.
states a hazard that may cause serious injury or death if precautions are not followed.
Another footnote we would like to identify is IMPORTANT NOTE: This highlights information that is especially relevant to a problemfree installation.
WOLF ® is a registered trademark of Wolf Appliance Company, Inc.
W O L F P R O V E N T I L AT I O N H O O D L I N E R S
I N S TA L L AT I O N R E Q U I R E M E N T S
IMPORTANT NOTE: This installation must be completed by a qualified installer or Wolf authorized service center technician. Installer: Please read the entire Installation Instructions prior to installation. [. . . ] It must be removed and reinstalled in the proper position. Refer to the illustration on the following page. Remove the filters by pushing each filter up at the angle it is placed in, and rotate down. Then take out the grease cups placed on the bottom edge of the hood liner coinciding with the bottom edge of the filters (Model L282212I only). Gloves should be worn to provide the proper grip when removing filters. Detach the rough-in plate/transition assembly from the hood liner by removing the screws on the top and back of the assembly. Separate the transition from the rough-in plate by removing the four shipping screws. Do not discard the screws, they will be needed to reinstall the transition to the rough-in plate.
Construct the wood wall framing flush with the wall studs and centered in the location that the hood liner will be mounted. Use the rough-in plate shipped with hood liner to determine the location of the framing. After the wall surface is finished, secure the rough-in plate assembly to the wall. In addition, be aware of local codes and ordinances when installing your service.
This ventilation hood liner must be properly grounded and should be installed by a qualified electrician in accordance with all applicable national and local electrical codes.
Run a 120 V AC, 15 amp circuit (minimum) power cable from the service panel to the electrical box in the rough-in plate. Remove the knockout and install the conduit connector on the rough-in plate hole. Refer to the illustration below for wiring location. Insert the conduit through the hole on top of the rough-in plate to the electrical box. Remove the electrical box cover from the rough-in plate. Connect black wire to power supply black wire, white wire to power supply white wire and green wire to green wire or bare wire. Place all wiring connections inside the electrical box and reinstall on the rough-in plate. Make sure that the wires are secure and that no wires are pinched between the cover and box. Refer to the wiring diagram packaged with the hood liner for more information.
Before servicing or cleaning, switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.
2 1/2" (64)
2" (51) 2 1/2" (64)
Pro hood liner wiring location
10
I N S TA L L AT I O N I N S T R U C T I O N S
INTERNAL B L OW E R
IMPORTANT NOTE: Refer to the installation instructions provided with the internal blower for additional mounting and wiring instructions. IMPORTANT NOTE: Use wire connectors or wire nuts approved by UL or C/UL. IMPORTANT NOTE: Wolf recommends installing the internal blower to the rough-in plate assembly prior to installing the hood liner to the wall framing. [. . . ] While pressing up against the spring, rotate the bottom edge of the filter into position (next to the grease cup on Model L282212I). Gloves should be worn to provide proper grip.
INTERNAL BLOWERS (805347) 600 CFM internal blower included with Model L282212I. LBLOWER-120INT (805087) 1200 CFM internal blower for all Pro hood liners except Model L282212I. IN-LINE BLOWERS BLOWER-110IL (808190) 1100 CFM in-line blower for all Pro hood liners except Model L282212I. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE SUB-ZERO PROLINER INSTALL GUIDE
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.