If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual SUB-ZERO PROWALLHOOD INSTALL GUIDE. We hope that this SUB-ZERO PROWALLHOOD INSTALL GUIDE user guide will be useful to you.
Lastmanuals help download the user guide SUB-ZERO PROWALLHOOD INSTALL GUIDE.
Manual abstract: user guide SUB-ZERO PROWALLHOOD INSTALL GUIDE
Detailed instructions for use are in the User's Guide.
[. . . ] P R O W A L L V E N T I L AT I O N H O O D S
INSTALLATION INSTRUCTIONS
C O N TA C T I N F O R M AT I O N
Wolf Customer Service: 800-332-9513 Website: wolfappliance. com
As you follow these instructions, you will notice WARNING and CAUTION symbols. This blocked information is important for the safe and efficient installation of Wolf equipment. There are two types of potential hazards that may occur during installation.
signals a situation where minor injury or product damage may occur if you do not follow instructions.
states a hazard that may cause serious injury or death if precautions are not followed.
Another footnote we would like to identify is IMPORTANT NOTE: This highlights information that is especially relevant to a problemfree installation.
WOLF ® is a registered trademark of Wolf Appliance Company, Inc.
W O L F P R O WA L L V E N T I L AT I O N H O O D S
I N S TA L L AT I O N R E Q U I R E M E N T S
IMPORTANT NOTE: This installation must be completed by a qualified installer or Wolf authorized service center technician. Installer: Please read the entire Installation Instructions prior to installation. [. . . ] Blower model numbers are listed on page 20.
Dimensions in parentheses are in millimeters unless otherwise specified.
13
W O L F P R O WA L L V E N T I L AT I O N H O O D S
27" (686) DEEP WA L L H O O D S
S T E P 2 : WA L L P R E PA R AT I O N
ACCESSORIES
Optional accessories are available through your Wolf dealer. To obtain local dealer information, visit the Locator section of our website, wolfappliance. com.
Framing must be tied together and to ceiling joists to provide enough structural strength to support the weight of the hood and internal blower, if applicable.
The hood assembly is shipped with the rough-in plate/transition attached. The transition is shipped upside down in the top of the hood. It must be removed and reinstalled in the proper position. Remove the filters by pushing each filter up at the angle it is placed in, and rotate down. Then take out the grease cups placed on the bottom edge of the hood coinciding with the bottom edge of the filters. Gloves should be worn to provide the proper grip when removing filters. Detach the rough-in plate/transition assembly from the hood by removing the screws on the top and back of the assembly. Separate the transition from the rough-in plate by removing the four shipping screws. Do not discard the screws, they will be needed to reinstall the transition to the rough-in plate. Reattach the transition to the rough-in plate using the four shipping screws removed previously. Attach the transition to existing ductwork with sheet metal screws and duct sealing tape.
Construct the wood wall framing flush with the wall studs and centered in the location that the hood will be mounted. Use the rough-in plate shipped with hood to determine the location of the framing. After the wall surface is finished, secure the rough-in plate to the wall surface.
If wall framing is not available, wall anchors must be used.
S T E P 3 : H O O D P R E PA R AT I O N IMPORTANT NOTE: If a duct cover is to be used, follow instructions on page 21 before installing the wall hood. Refer to the illustration below for the location of mounting holes for the 27" (686) wall hood.
91/2" (241) 21 1/4" (540) 10" (254) 41/2" (114) * 8 1/2" (216) 20" (508) 8" (203) * 41/2" (114) * * 41/2"
(114) 13/16" (21)
Shipping Screws
Rough-In Plate Transition
*
*
41/2"
(114)
*
* *Dimension is 2" (51)
Mounting holes for 27" (686) hoods
Rough-in plate installation
14
I N S TA L L AT I O N I N S T R U C T I O N S
27" (686) DEEP WA L L H O O D S
If you are installing WBLOWER-90INT or WBLOWER-120INT, refer to the internal blower information on page 17 and follow installation instructions provided with the blower. If you are installing an in-line or remote blower, drill a 7/8" (22) hole through the wood framing for the conduit. Refer to the in-line and remote blower information on pages 1819 and follow installation instructions provided with the blower. IMPORTANT NOTE: Do not run wiring for the remote blower through the ductwork. S T E P 4 : I N S TA L L R O U G H - I N P L AT E Use the rough-in plate assembly to determine the location of wall framing. Install the #10 x 1" (25) screws (included with the hood) through the rough-in plate into the wall framing. IMPORTANT NOTE: If additional support is required for the hood, drill supplementary mounting holes in the rough-in plate and use these holes to attach the hood assembly to the wall framing.
S T E P 5 : I N S TA L L T H E H O O D IMPORTANT NOTE: If a backsplash is to be used, it should be installed before the wall hood is mounted. Align both ends of the hood assembly with the ends of the rough-in plate. [. . . ] For 27" (686) wall hoods follow hood installation instructions on page 13. Duct covers 6" (152) and 12" (305) high in widths to match all wall hoods are available through your Wolf dealer. To obtain local dealer information, visit the Locator section of our website, wolfappliance. com.
Optional Duct Cover
Spring
Mounting Screws
Filter
Grease Cup
SIDE VIEW
Duct cover installation Dimensions in parentheses are in millimeters unless otherwise specified.
Filter and grease cup installation
21
W O L F P R O WA L L V E N T I L AT I O N H O O D S
N A M E P L AT E I N S T A L L A T I O N
TROUBLES H O OT I N G
The Wolf logo nameplate does not come installed on the hood since there are various locations that the nameplate can be attached. Also, some customers prefer not to have a nameplate on their hood. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE SUB-ZERO PROWALLHOOD INSTALL GUIDE
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.