[. . . ] As with the Attack Switch, there are three settings: Fast, Medium and Slow. The release time setting is also controlled by the program material. The slower the release time setting, the more the program material determines and the release time.
Meter Switch
This control switches the front panel meter to monitor either the output level or the amount of gain reduction taking place.
Gain
This control sets the overall gain of the TLA-50. [. . . ] The TLA-50 providing the most compression will always control the other unit.
To "stereo link" two units:
1. 3.
Connect a standard 1/4" cable between the two units. Set the controls on both units the same. Set the BYPASS switch on the front panel to LINK.
Balanced Input
The dual purpose input jack accepts XLR plugs for balanced inputs and standard 1/4" plugs for unbalanced inputs. Maximum signal input level is +26dBm.
6
Summit Audio, Inc.
Basic Operation
Important: For proper operation of the TLA-50 (or any vacuum tube device for that matter), allow the unit to warm up with power on for 15 minutes before use.
Four Easy Steps
1. 4.
Set the Gain Reduction control to 0 and adjust the Gain control for 0 VU on the meter. Switch the attack to slow and the release to fast. Adjust for the desired amount of gain reduction and recheck the output level. Try different attack and release settings, depending upon the program.
No Gain Reduction
Important: Do not block the cooling holes and allow adequate ventilation.
OUTPUT LEVEL
INPUT LEVEL
As the amount of gain reduction is increased, the processed audio follows a smooth reduction curve, thereby changing the compression ratio.
If a large peak is detected, the unit will automatically increase the compression ratio to keep the audio output controlled.
Model TLA-50 Tube Leveling Amplifier
7
Applications
Applications
Tracking, Live Sound Mixing
Plug the TLA-50 into the insert jack or patch bay of your mixing console. If you're using an external microphone preamplifier, connect the TLA-50 directly after the preamp.
Insert Connection
20 WATTS MAX
TLA-50
CLASS A -TUBE LEVELER MODEL TLA-50
PUSH
OUTPUTS
100V 50/60 HZ
SIDE CHAIN
FUSE
115V 50/60 HZ SUMMIT AUDIO INC.
CARMEL, CA USA
+4 BAL.
-10 UNBAL.
INSERT
LINK
INPUT +4 BAL. -10 UNBAL.
Signal Out of Mixer Signal Return to Mixer
To Ring
To Tip
Tip TLA-50 Input
Ring TLA-50 Output
Channel Insert
INSERT CABLE
Signal is sent out on tip of plug and returned to mixer via ring of plug.
Mixer
8
Summit Audio, Inc.
Applications
Basic In-line Connection of the TLA-50
Inline Connection
TLA-50
20 WATTS MAX
CLASS A -TUBE LEVELER MODEL TLA-50
PUSH
MIC PREAMP
SIDE CHAIN 20 WATTS MAX
CLASS A -TUBE PREAMP MODEL
PUSH
OUTPUTS
OUTPUTS
100V 50/60 HZ
100V 50/60 HZ
FUSE
115V 50/60 HZ SUMMIT AUDIO INC.
CARMEL, CA USA
+4 BAL.
-10 UNBAL.
INSERT
LINK
INPUT +4 BAL. -10 UNBAL.
FUSE
115V 50/60 HZ SUMMIT AUDIO INC.
CARMEL, CA USA
+4 BAL.
-10 UNBAL.
INPUT +4 BAL. -10 UNBAL.
Input
Output
Channel Input
Mixer
Model TLA-50 Tube Leveling Amplifier
9
Applications
Compressing a Stereo Mix
Insert a 1/4" cable into two TLA-50's link jacks, set the attack and release switches and gain reduction on both units to the same settings. The channel with the strongest signal will lead both units.
TLA-50
20 WATTS MAX
CLASS A -TUBE LEVELER MODEL TLA-50
PUSH
TLA-50
SIDE CHAIN 20 WATTS MAX
CLASS A -TUBE LEVELER MODEL TLA-50
PUSH
OUTPUTS
OUTPUTS
100V 50/60 HZ
100V 50/60 HZ
SIDE CHAIN
FUSE
115V 50/60 HZ SUMMIT AUDIO INC.
CARMEL, CA USA
+4 BAL.
-10 UNBAL.
INSERT
LINK
INPUT +4 BAL. -10 UNBAL.
FUSE
115V 50/60 HZ SUMMIT AUDIO INC.
CARMEL, CA USA
+4 BAL.
-10 UNBAL.
INSERT
LINK
INPUT +4 BAL. -10 UNBAL.
1/4" mono phone cable
Set controls to the same settings on both units.
De-essing
Plug a TRS insert cable into the side chain jack on the back of the TLA-50. Plug the send (tip) of the insert cable to the input of an EQ, and the return (ring) of the cable to the EQ output. Boost the frequencies on the EQ that you want to compress (de-ess).
EQUALIZER
Input Output
20 WATTS MAX
TLA-50
CLASS A -TUBE LEVELER MODEL TLA-50
PUSH
OUTPUTS
100V 50/60 HZ
SIDE CHAIN
FUSE
115V 50/60 HZ SUMMIT AUDIO INC.
CARMEL, CA USA
+4 BAL.
-10 UNBAL.
INSERT
LINK
INPUT +4 BAL. [. . . ] The balanced output drivers provide a low output impedance for driving cables and 600 loads.
Model TLA-50 Tube Leveling Amplifier
13
Electrical Connections
Electrical Connections
Input
Note: The Input connector accepts either a 1/4" phone plug or an XLR connector.
Unbalanced 1/4" jack
Sleeve - - Ground Tip - - - - (+) Signal
Balanced 3-pin XLR
Pin 1 - - Ground Pin 2 - - (+) Signal Pin 3 - - (-) Signal
Output Unbalanced 1/4" jack
Sleeve - - Ground Tip - - - - (+) Signal
Balanced 3-pin XLR
Pin 1 - - Ground Pin 2 - - (+) Signal Pin 3 - - (-) Signal
Side Chain
Tip - - - - Signal output to EQ Ring - - - Signal input (from EQ) Sleeve- - Ground
Stereo Link
Tip - - - - Signal Sleeve- - Ground Use a shielded patch cord with 1/4" plug. 14
Summit Audio, Inc.
Specifications
Specifications
Output
+4 dBm corresponds to 0 VU. The output is electronically balanced or unbalanced. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE SUMMIT TLA-50
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.