User manual SUMMIT TLA-50

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual SUMMIT TLA-50. We hope that this SUMMIT TLA-50 user guide will be useful to you.

Lastmanuals help download the user guide SUMMIT TLA-50.


Mode d'emploi SUMMIT TLA-50
Download
Manual abstract: user guide SUMMIT TLA-50

Detailed instructions for use are in the User's Guide.

[. . . ] As with the Attack Switch, there are three settings: Fast, Medium and Slow. The release time setting is also controlled by the program material. The slower the release time setting, the more the program material determines and the release time. Meter Switch This control switches the front panel meter to monitor either the output level or the amount of gain reduction taking place. Gain This control sets the overall gain of the TLA-50. [. . . ] The TLA-50 providing the most compression will always control the other unit. To "stereo link" two units: 1. 3. Connect a standard 1/4" cable between the two units. Set the controls on both units the same. Set the BYPASS switch on the front panel to LINK. Balanced Input The dual purpose input jack accepts XLR plugs for balanced inputs and standard 1/4" plugs for unbalanced inputs. Maximum signal input level is +26dBm. 6 Summit Audio, Inc. Basic Operation Important: For proper operation of the TLA-50 (or any vacuum tube device for that matter), allow the unit to warm up with power on for 15 minutes before use. Four Easy Steps 1. 4. Set the Gain Reduction control to 0 and adjust the Gain control for 0 VU on the meter. Switch the attack to slow and the release to fast. Adjust for the desired amount of gain reduction and recheck the output level. Try different attack and release settings, depending upon the program. No Gain Reduction Important: Do not block the cooling holes and allow adequate ventilation. OUTPUT LEVEL INPUT LEVEL As the amount of gain reduction is increased, the processed audio follows a smooth reduction curve, thereby changing the compression ratio. If a large peak is detected, the unit will automatically increase the compression ratio to keep the audio output controlled. Model TLA-50 Tube Leveling Amplifier 7 Applications Applications Tracking, Live Sound Mixing Plug the TLA-50 into the insert jack or patch bay of your mixing console. If you're using an external microphone preamplifier, connect the TLA-50 directly after the preamp. Insert Connection 20 WATTS MAX TLA-50 CLASS A -TUBE LEVELER MODEL TLA-50 PUSH OUTPUTS 100V 50/60 HZ SIDE CHAIN FUSE 115V 50/60 HZ SUMMIT AUDIO INC. CARMEL, CA USA +4 BAL. -10 UNBAL. INSERT LINK INPUT +4 BAL. -10 UNBAL. Signal Out of Mixer Signal Return to Mixer To Ring To Tip Tip TLA-50 Input Ring TLA-50 Output Channel Insert INSERT CABLE Signal is sent out on tip of plug and returned to mixer via ring of plug. Mixer 8 Summit Audio, Inc. Applications Basic In-line Connection of the TLA-50 Inline Connection TLA-50 20 WATTS MAX CLASS A -TUBE LEVELER MODEL TLA-50 PUSH MIC PREAMP SIDE CHAIN 20 WATTS MAX CLASS A -TUBE PREAMP MODEL PUSH OUTPUTS OUTPUTS 100V 50/60 HZ 100V 50/60 HZ FUSE 115V 50/60 HZ SUMMIT AUDIO INC. CARMEL, CA USA +4 BAL. -10 UNBAL. INSERT LINK INPUT +4 BAL. -10 UNBAL. FUSE 115V 50/60 HZ SUMMIT AUDIO INC. CARMEL, CA USA +4 BAL. -10 UNBAL. INPUT +4 BAL. -10 UNBAL. Input Output Channel Input Mixer Model TLA-50 Tube Leveling Amplifier 9 Applications Compressing a Stereo Mix Insert a 1/4" cable into two TLA-50's link jacks, set the attack and release switches and gain reduction on both units to the same settings. The channel with the strongest signal will lead both units. TLA-50 20 WATTS MAX CLASS A -TUBE LEVELER MODEL TLA-50 PUSH TLA-50 SIDE CHAIN 20 WATTS MAX CLASS A -TUBE LEVELER MODEL TLA-50 PUSH OUTPUTS OUTPUTS 100V 50/60 HZ 100V 50/60 HZ SIDE CHAIN FUSE 115V 50/60 HZ SUMMIT AUDIO INC. CARMEL, CA USA +4 BAL. -10 UNBAL. INSERT LINK INPUT +4 BAL. -10 UNBAL. FUSE 115V 50/60 HZ SUMMIT AUDIO INC. CARMEL, CA USA +4 BAL. -10 UNBAL. INSERT LINK INPUT +4 BAL. -10 UNBAL. 1/4" mono phone cable Set controls to the same settings on both units. De-essing Plug a TRS insert cable into the side chain jack on the back of the TLA-50. Plug the send (tip) of the insert cable to the input of an EQ, and the return (ring) of the cable to the EQ output. Boost the frequencies on the EQ that you want to compress (de-ess). EQUALIZER Input Output 20 WATTS MAX TLA-50 CLASS A -TUBE LEVELER MODEL TLA-50 PUSH OUTPUTS 100V 50/60 HZ SIDE CHAIN FUSE 115V 50/60 HZ SUMMIT AUDIO INC. CARMEL, CA USA +4 BAL. -10 UNBAL. INSERT LINK INPUT +4 BAL. [. . . ] The balanced output drivers provide a low output impedance for driving cables and 600 loads. Model TLA-50 Tube Leveling Amplifier 13 Electrical Connections Electrical Connections Input Note: The Input connector accepts either a 1/4" phone plug or an XLR connector. Unbalanced 1/4" jack Sleeve - - Ground Tip - - - - (+) Signal Balanced 3-pin XLR Pin 1 - - Ground Pin 2 - - (+) Signal Pin 3 - - (-) Signal Output Unbalanced 1/4" jack Sleeve - - Ground Tip - - - - (+) Signal Balanced 3-pin XLR Pin 1 - - Ground Pin 2 - - (+) Signal Pin 3 - - (-) Signal Side Chain Tip - - - - Signal output to EQ Ring - - - Signal input (from EQ) Sleeve- - Ground Stereo Link Tip - - - - Signal Sleeve- - Ground Use a shielded patch cord with 1/4" plug. 14 Summit Audio, Inc. Specifications Specifications Output +4 dBm corresponds to 0 VU. The output is electronically balanced or unbalanced. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE SUMMIT TLA-50

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual SUMMIT TLA-50 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag