Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual SUUNTO COBRA. We hope that this SUUNTO COBRA user guide will be useful to you.
Lastmanuals help download the user guide SUUNTO COBRA.
Detailed instructions for use are in the User's Guide.
[. . . ] EN
SUUNTO COBRA
USER'S GUIDE
Arrows: - Decompression Stop at the Ceiling Depth - Mandatory Safety Stop Zone - Ascent Recommended - Must Descend
Present Depth Dive Counter
Maximum Depth Ceiling Depth on Decompression Stop Mandatory Safety Stop Depth Average Depth in Logbook Oxygen Partial Pressure AM/PM Indicator Safety Stop Warning Safety Stop Indicator Fast Ascent Warning (SLOW)
Bookmark Symbol
DIVE
CEILING
m ft
Diver Attention Symbol
Bar Graph: - Ascent Rate Indicator - Battery Power Indicator - Logbook Page Indicator
Quick Reference Guide
Bar Graph: - Mode Indicator - Consumed Bottom Time - Oxygen Limit Fraction
NO O2%SURF
OK SELECT
S L O AVGPO2 MAX W STOP ASC TIME QUIT
Do Not Fly Icon
Remaining Air Time / Oxygen Percentage in Nitrox Mode
Current Time Display Surface Interval Time No Flying Time No-Decompression Time Total Ascent Time Safety Stop Time
AIR TIME
NO DEC TIME
Altitude Adjustment Mode
The Smart Button: - Activation - Backlight - Mode Operations Smart Button Indicators
Personal Adjustment Mode
OLF C B T °F°Cbar °Cbar
psi
OPTIONS
DIVE TIME
Cylinder Pressure Temperature Week Day Mode Text
Low Battery Warning Dive Time Time Month, Day Daily/DiveTime/Depth Alarm On Indicator Time (alternative display) Button Scroll Button (decrease value, descend)
Scroll Button Indicators
Plan Button Scroll Button (increase value, ascend)
DEFINITION OF WARNINGS, CAUTIONS AND NOTES
Throughout this manual, special references are made when deemed important. Three classifications are used to separate these references by their order of importance. WARNING CAUTION NOTE is used in connection with a procedure or situation that may result in serious injury or death. is used in connection with a procedure or situation that will result in damage to the product. [. . . ] SLOW and STOP warnings will appear (Fig. the Mandatory Safety Stop ceiling is exceeded. A downward pointing arrow will appear (Fig. the decompression ceiling depth is exceeded. An error warning Er and a downward pointing arrow appear. You should immediately descend to, or below, the ceiling. The instrument will otherwise enter a permanent Error Mode within three minutes, indicated by a permanent Er (Fig. 3. 19. ).
35
You are able to preset alarms before the actual dive. The user programmable alarms can be set for maximum depth, dive time and time. The alarms activate when: · The preset maximum depth is reached - continuous beep series for 24 seconds or until any button is pressed. - the maximum depth blinks as long as the present depth value exceeds the adjusted value. The preset dive time is reached - continuous beep series for 24 seconds or until any button is pressed. - the dive time blinks for one minute, if no button is pressed. The preset alarm time is reached - the current time is shown. - continuous beep series for 24 seconds or until any button is pressed. - the current time blinks for one minute, if no button is pressed.
·
·
OXYGEN ALARMS IN NITROX MODE
Three double beeps and the backlight activated for 5 seconds occur, when: the OLF bar graph reaches 80%. The segments exceeding the 80% limit start to blink (Fig. 3. 24. ) · the OLF bar graph reaches 100%. The blinking of the segments exceeding 80% will stop, when the OLF is not loading anymore. At that point the PO2 is less than 0. 5 bar. Continuous beeps for 3 minutes and the backlight activated for 5 seconds occur, when: · the set oxygen partial pressure limit is exceeded. The maximum depth is replaced with a current blinking PO2 value. [. . . ] The maximum amount of time a diver may remain at a particular depth without having to make decompression stops during the subsequent ascent. No-decompression dive Any dive which permits a direct, uninterrupted ascent to the surface at any time. NO DEC TIME OLF Abbreviation for no-decompression time limit. 69 OEA = EAN = EANx Abbreviation for Oxygen Enriched Air Nitrox.
HP Multi-level dive
NITROX NOAA
No-decompression time
Oxygen Tolerance Unit Is used to measure the Whole-Body-Toxicity. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE SUUNTO COBRA
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.
Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual SUUNTO COBRA will begin.