User manual SUUNTO COBRA 3

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual SUUNTO COBRA 3. We hope that this SUUNTO COBRA 3 user guide will be useful to you.

Lastmanuals help download the user guide SUUNTO COBRA 3.


Mode d'emploi SUUNTO COBRA 3
Download
Manual abstract: user guide SUUNTO COBRA 3

Detailed instructions for use are in the User's Guide.

[. . . ] EN COBRA3 USER'S GUIDE Time Tank pressure 1. WELCOME TO THE WORLD OF SUUNTO DIVING INSTRUMENTS . . . . . . . . . . . . . . . . WARNINGS, CAUTIONS, AND NOTES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SUUNTO AT A GLANCE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] The ascent time (ASC TIME) is the minimum amount of time needed to reach the surface in a decompression dive. It includes: · the time needed to ascend to the ceiling at an ascent rate of 10 m/33 ft per minute. The ceiling is the shallowest depth to which you should ascend · the time needed at the ceiling · the time needed at the Mandatory Safety Stop (if any) · the time needed to reach the surface after the mandatory decompression dives have been completed 29 NOTE WARNING In addition, there may also be Mandatory Safety Stops which are not displayed in ASC TIME. YOUR ACTUAL ASCENT TIME MAY BE LONGER THAN DISPLAYED BY THE INSTRUMENT!The ascent time will increase if you: · remain at depth · ascend slower than 10 m/33 ft per minute · make your decompression stop deeper than at the ceiling These factors will also increase the amount of air required to reach the surface. Ceiling, ceiling zone, floor and decompression range When in decompression, it is important that you understand the meaning of ceiling, floor, and decompression range. · The ceiling is the shallowest depth to which you should ascend when in decompression. At this depth, or below, you must perform all stops · The ceiling zone is the optimum decompression stop zone. It is the zone between the minimum ceiling and 1. 2 m/4 ft below the minimum ceiling · The floor is the deepest depth at which the decompression stop time will not increase. Decompression will start when you pass this depth during your ascent · The decompression range is the depth range between the ceiling and floor. Within this range, decompression takes place. However, it is important to remember that the decompression will be very slow at, or close to, the floor The depth of the ceiling and floor will depend on your dive profile. The ceiling depth will be fairly shallow when you enter the decompression mode, but if you remain at depth, it will move downward and the ascent time will increase. Likewise, the floor and ceiling may change upwards while you are decompressing. When conditions are rough, it may be difficult to maintain a constant depth near the surface. In such cases, it is more manageable to maintain an additional distance below the ceiling, to make sure that the waves do not lift you above the ceiling. Suunto recommends that decompression takes place deeper than 4 m/13 ft, even if the indicated ceiling is shallower. NOTE WARNING It will take more time and more air to decompress below the ceiling than at the ceiling. You must not ascend above the ceiling during your decompression. In order to avoid doing so by accident, you should stay somewhat below the ceiling. Display below the floor The blinking ASC TIME and an upward pointing arrow indicate that you are below the floor. You should start your ascent immediately. The ceiling depth is shown on the left side, and the minimum total ascent time on the right side, of the center window. Below is an example of a decompression dive without Deep Stops, below the floor. [. . . ] The value is either the CNS% or the OTU%. Oxygen percentage or oxygen fraction in the breathing gas. Limits the maximum depth to which the nitrox mixture can be safely used. The maximum partial pressure limit for enriched air diving is 1. 4 bar. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE SUUNTO COBRA 3

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual SUUNTO COBRA 3 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag