Manual abstract: user guide SUUNTO SK-5POCKET GUIDE
Detailed instructions for use are in the User's Guide.
[. . . ] The hose cover ensures that the SM-26/36 pressure gauge fits properly on the CB-ONE module.
If the Suunto Quick Release is used, the hose cover is not to be used (See section CB-ONE module assembly using the SUUNTO Quick Release). After attaching the hose cover the pressure hose and gauge are assembled on the CB-ONE front cover according to the picture.
After the pressure gauge is in place the CB-ONE back cover (or alternatively the CB-71/SK-7/DS compass) is attached with four screws.
5
CB-ONE Module Assembly when using the SUUNTO Quick Release
If the SUUNTO Quick Release (QR) is used the hose cover should be attached on the high pressure hose below the female end of the QR. The male part is attached to the pressure gauge which is then fitted onto the CB-ONE front cover according to the picture below.
CB-IN-LINE Module Assembly
The CB-IN-LINE module fits the Suunto Vyper, Gekko, Solution, Favor/Fusion, Octopus II and Companion dive computers or the SM-16 round depth gauge. The Vyper locks in place on the IN-LINE module back cover. [. . . ] For the other instruments there are lugs on the back cover aiding the orientation.
The Solution, Favor and Companion can be fitted with display shield V5615. The display shield is attached after the console has been assembled by bending the console so that the shield fits between the computer and the console cover. The Vyper is delivered with a pre-attached display shield (V5875).
6
SUUNTO Console Compasses CB-71/SK-7/STD and CB-71/SK-7/DS
The high-quality, liquid-filled Suunto diving compasses are durable, reliable and easy to use. The CB-71/SK-7 is available in two versions: the CB-71/SK-7/STD for attachment on top of the combo modules or the Cobra dive computer, and the CB-71/SK-7/DS for attachment on the back side of the CB-ONE module.
Compass use for divers
General instructions Usually a compass must be held precisely in a horizontal position, otherwise the needle will sting. The SK-7 compass may however be inclined about ±30 degrees. Sighting a compass bearing Hold the compass so that the compass is in a horizontal position and the direction line points away from you. Turn with the compass until the direction line points at your destination, then turn the direction ring until the magnetic North needle is aligned between the slit marks. The front end of the direction line on the SK-7 shows your compass bearing, and as long as the North needle is aligned between the slit marks, the direction points toward your destination. The SK-7 compasses also have a side reading window, which also enables you to take a bearing by directing the compass towards the destination and by reading the compass bearing from the side window. This bearing can be memorized by turning the direction ring to that bearing. Setting a given bearing or direction The scale division on the SK-7 is 360 degrees clockwise from 0 degrees at North. Repeated unnecessary adjustments may cause excessive wear to the seals and eventual leakage. Do not attempt to adjust the water entry port located at the left side of gauge. Tampering with the port can cause damage to internal components. Always immerse the gauge in water while pressure testing it. Pressure gauge: The hose has an end fitting with 7/16" 20 UNF-thread. If your regulator has a different thread size in the high pressure (HP-output) port, ask your dealer for the correct adapter. Always inspect the o-ring at the male thread to be sure it is clean and undamaged before connecting it to the regulator. Always turn the pressure gauge dial face away from your face when turning on the air supply. Do not overtighten the hose at the gauge, the fitting is pressure proof even when tightened with fingers.
Service
Avoid subjecting the gauges to excessive shock loads such as those that might occur from being dropped or hit against an immovable object. Do not subject the gauges to pressures beyond their maximum range. In general, the gauges should not be exposed to temperatures to which you would not expose yourself. [. . . ] Do not subject the gauges to pressures beyond their maximum range. In general, the gauges should not be exposed to temperatures to which you would not expose yourself. After use: Rinse the gauges or the console with fresh water and store them out of direct sunlight, in a dry place at room temperature. Do not attempt to clean the gauges with anything other than water. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE SUUNTO SK-5
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.