User manual SUUNTO ZOOP

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual SUUNTO ZOOP. We hope that this SUUNTO ZOOP user guide will be useful to you.

Lastmanuals help download the user guide SUUNTO ZOOP.


Mode d'emploi SUUNTO ZOOP
Download
Manual abstract: user guide SUUNTO ZOOP

Detailed instructions for use are in the User's Guide.

[. . . ] EN SUUNTO ZOOP USER'S GUIDE Quick reference guide ZOOP Maximum Depth Ceiling Depth on Decompression Mandatory Safety Stop Depth Average Depth on Logbook Oxygen Partial Pressure AM/PM Indicator Safety Stop Warning Safety Stop Indicator Fast Ascent Warning (SLOW) Bar Graph: - Ascent Rate Indicator - Battery Power Indicator - Logbook Page Indicator Arrows: - Decompression Stop at the Ceiling Depth - Mandatory Safety Stop Zone - Ascent Recommended - Must Descend Present Depth Dive Counter Logbook Symbol Dive Attention Symbol Bar Graph: - Mode Indicator - Consumed Botton Time - Oxygen Limit Fraction Do Not Fly Icon Current Time Display Surface Interval Time No Flying Time No-Decompression Time Total Ascent Time Safety Stop Time The Smart Button: - Activation - Mode Operations Indicators for the Smart Button Oxygen Percentage in Nitrox Mode High Altitude Mode Personal Adjustment Mode °C Low Battery Warning Dive Time Time Month, Day DiveTime/Depth Alarm On Indicator Time (alternative display) Button Scroll Button (decrease value, descend) Temperature Week Day Mode Text Indicators for the Scroll Buttons Dive Planning Button Scroll Button (increase value, ascend) DEFINITION OF WARNINGS, CAUTIONS AND NOTES Throughout this manual, special references are made when deemed important. Three classifications are used to separate these references by their order of importance. WARNING CAUTION NOTE is used in connection with a procedure or situation that may result in serious injury or death. is used in connection with a procedure or situation that will result in damage to the product. [. . . ] The blinking of the segments exceeding 80% will stop, when the OLF is not loading anymore. At that point the PO2 is less than 0. 5 bar. Continuous beeps for 3 minutes occur, when: the set oxygen partial pressure limit is exceeded. The maximum depth is replaced with a current blinking PO2 value. You should immediately ascend above the PO2 depth limit (Fig. 3. 23. ). - WARNING! WHEN THE OXYGEN LIMIT FRACTION INDICATES THAT THE MAXIMUM LIMIT IS REACHED, YOU MUST IMMEDIATELY ASCEND UNTIL THE WARNING STOPS BLINKING!Failure to take action to reduce oxygen exposure after the warning is given can rapidly increase the risk of oxygen toxicity and the risk of injury or death. 3. 7. HIGH ALTITUDE DIVES AND PERSONAL ADJUSTMENT The dive computer can be adjusted both for diving at altitude and also to increase the conservatism of the mathematical nitrogen model. 3. 7. 1. Altitude Adjustment When programming the instrument for the correct altitude, you need to select the correct Altitude Mode according to Table 3. 4. The dive computer will adjust its mathematical model according to the entered altitude mode, giving shorter nodecompression times at higher altitudes (see Section 6. 1. "Operating Principles", Table 6. 1. ALTITUDE ADJUSTMENT RANGES Altitude mode A0 A1 A2 Symbol on display Altitude range 0 - 300 m [0 - 1000 ft] 300 - 1500 m [1000 - 5000 ft] 1500 - 3000 m [5000 - 10000 ft] The entered Altitude Adjustment Mode is indicated by mountain symbols (A0, A1 = one mountain, or A2 = two mountains). " Personal Adjustments" describes how the Altitude Mode is adjusted. 34 Traveling to a higher elevation can temporarily cause a change in the equilibrium of dissolved nitrogen in the body. It is recommended that you acclimate to the new altitude by waiting at least three hours before making a dive. 3. 7. 2. Personal Adjustment There are adverse personal factors for DCI which divers can predict in advance and input into the decompression model. Factors that may affect susceptibility to decompression illness vary between divers and also for the same diver from one day to another. The three-step Personal Adjustment Mode is available, if a more conservative dive plan is desired. The personal factors which tend to increase the possibility of DCI include, but are not limited to: - cold exposure - water temperature less than 20°C [68°F] - the diver is below average physical fitness level - diver fatigue - diver dehydration - previous history of DCI - stress - obesity The Personal Adjustment Mode is indicated by a diver symbol and plus signs (P0 = a diver, P1 = diver +, or P2 = diver ++). " Personal Adjustments" describes how the Personal Mode is adjusted. This feature should be used to adjust the computer to be more conservative, according to personal preference, by entering the suitable Personal Adjustment Mode with the help of Table 3. 5. In ideal conditions, retain the default setting, P0. If conditions are more difficult or other mentioned factors which tend to increase the possibility of DCI exist, select P1 or even the most conservative P2. [. . . ] OLF Abbreviation for Oxygen Limit Fraction. OTU Abbreviation for Oxygen Tolerance Unit. Oxygen Tolerance Unit Is used to measure the Whole-Body-Toxicity. 67 Oxygen Limit Fraction A term used by SUUNTO for the values displayed in the Oxygen Toxicity bargraph. The value is either the CNS% or the OTU%. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE SUUNTO ZOOP

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual SUUNTO ZOOP will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag