Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual SYLVANIA QHE T8 ISN CC. We hope that this SYLVANIA QHE T8 ISN CC user guide will be useful to you.
Lastmanuals help download the user guide SYLVANIA QHE T8 ISN CC.
Manual abstract: user guide SYLVANIA QHE T8 ISN CCDATASHEET
Detailed instructions for use are in the User's Guide.
[. . . ] www. sylvania. com
QUICKTRONIC® T8 Instant Start Universal Voltage
High Efficiency Series
Type CC Lamp Striation Control Normal Ballast Factor
QHE T8 ISN CC
Lamp/Ballast Guide
32W T8 - OCTRON 1-lamp QHE1x32T8/UNV-ISN-SC-1 2-lamp QHE2x32T8/UNV-ISN-SC-1 3-lamp QHE3x32T8/UNV-ISN-SC-1 4-lamp QHE4x32T8/UNV-ISN-SC-1
®
SYLVANIA QUICKTRONIC High Efficiency, (QHE) Type CC energy saving electronic T8 ballasts offer four major advantages: 1. [. . . ] of (lm) Lamps
2800 3000 2850 2725 2475 2800 3000 2850 2725 2475 2800 3000 2850 2725 2475 2800 3000 2850 2725 2475 1 1 1 1 1 2 2 2 2 2 3 3 3 3 3 4 4 4 4 4
Ballast Factor System (BF) Lumens
0. 87 0. 87 0. 87 0. 87 0. 87 0. 87 0. 87 0. 87 0. 87 0. 87 0. 87 0. 87 0. 87 0. 87 0. 87 0. 87 0. 87 0. 87 0. 87 0. 87 2435 2610 2480 2370 2155 4870 5220 4960 4740 4305 7305 7830 7440 7110 6460 9745 10, 440 9920 9485 8615
Mean Lumens
2190 2455 2330 2230 2025 4385 4905 4660 4455 4050 6575 7360 6990 6685 6070 8770 9815 9325 8915 8095
Input Wattage (W)
28 28 27/26 25/24 23/22 55 55 52 48/47 44/43 82/81 82/81 77/76 72/71 65/64 109/107 109/107 102 95/94 87/86
BEF1
3. 11 3. 11 3. 35 3. 63 3. 95 1. 58 1. 58 1. 67 1. 85 2. 02 1. 07 1. 07 1. 14 1. 23 1. 36 0. 81 0. 81 0. 85 0. 93 1. 01
Data based upon SYLVANIA OCTRON® lamps shown. QUICKTRONIC® QHE Instant Start ballasts are also compatible with other manufacturers equivalent lamp types that meet ANSI specifications. QHE Instant Start ballasts will also operate F17, F25, F32 and the U-Bend equivalent & energy saving T8 lamps. Complete performance data is available in the QUICKSYSTEMS section of the SYLVANIA Electronic Ballast Catalog.
NEW!
QHE T8 ISN CC
QHE2x32T8/UNV-ISN-SC-1 49383
49384 Banded Pack Pallet Pack
QHE3x32T8/UNV-ISN-SC-1 49385
49386 Banded Pack Pallet Pack
Specifications Data based on F32T8
Starting Method: Instant Start Ballast Factor: 0. 87 Circuit Type: Parallel Lamp Frequency: >40kHz Lamp CCF: Less than 1. 7 Starting Temp: 2 -20°F (-29°C) for OCTRON T8 lamps; 60°F (16°C) for SUPERSAVER® T8 lamps 0°F (-18°C) for FO40T8 Input Frequency: 50/60 Hz Low THD: <10% Power Factor: >98% Voltage Range: ±10% of 120-277V rated line (108-305V) UL Listed Class P, Type 1 Outdoor UL Type CC Rated CSA Certified 70°C Max Case Temperature FCC 47 CFR Part 18 Non-Consumer Class A Sound Rating ANSI 62. 41 Cat. A Transient Protection GFCI compatible Emergency ballast compatible Remote Mounting (Max wire length from ballast case to lampholder): · 20 ft: full wattage T8s · 10 ft: energy saving T8s · 4 ft: 25W energy saving T8s
2 Operation below 50°F (10°C) may affect light output or lamp operation see "Low Temp. Starting" definition.
QHE4x32T8/UNV-ISN-SC-1 49387
49388 Banded Pack Pallet Pack
Banded Pack contains 10 pieces, (add "-B" to Description). Pallet Pack contains 840 pieces, (add "-PAL" to Description). 1: Ballast Efficiency Factor (BEF) shown = (Ballast Factor x 100) divided by Input Power (Note: calculation based on lowest wattage value).
Black White Red Blue Blue
Black/White White Red
Blue
BALLAST
BALLAST
LAMP LAMP LAMP
Note: For one lamp application, cap any blue lead. [. . . ] OSRAM SYLVANIA National Customer Service and Sales Center 1-800-LIGHTBULB (1-800-544-4828) www. sylvania. com 25
QUICKTRONIC 4x32
Dimensions: Overall: 9. 5" L x 1. 68" W x 1. 18" H Mounting: 8. 90" Product Weight: 1. 6 lbs each (approx)
Wiring: Leads only (no connectors provided)
Height 8. 70 mm Slot Width Mounting Length Length
Item Number QUICKTRONIC High Efficiency Number of Lamps Primary Lamp Wattage
Specifications subject to change without notice.
49383 QHE 2 x 32T8 / UNV ISN - SC - 1
UL Type CC Case Size Starting/Ballast Factor Line Voltage (120-277V) [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE SYLVANIA QHE T8 ISN CC
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.
Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual SYLVANIA QHE T8 ISN CC will begin.