User manual SYLVANIA QTP T8 ISN DATASHEET

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual SYLVANIA QTP T8 ISN. We hope that this SYLVANIA QTP T8 ISN user guide will be useful to you.

Lastmanuals help download the user guide SYLVANIA QTP T8 ISN.


Mode d'emploi SYLVANIA QTP T8 ISN
Download
Manual abstract: user guide SYLVANIA QTP T8 ISNDATASHEET

Detailed instructions for use are in the User's Guide.

[. . . ] www. sylvania. com QUICKTRONIC® T8 Instant Start Universal Voltage Normal Ballast Factor Professional Series Lamp / Ballast Guide 32W T8 - OCTRON® 1-lamp QTP1x32T8 ISN-SC 2-lamp QTP2x32T8 ISN-SC 3-lamp QTP3x32T8 ISN-SC 4-lamp QTP4x32T8 ISN-SC Also operates: FBO32, FBO31, FO25, FBO24, FO17, FBO16, FO30/SS (30W), FBO30/SS (30W), FBO29/SS (29W), FO28/SS (28W) & FO25/SS (25W) FO40T8 operation: 1 lamp on 2L ballast, 2 lamps on 3L ballast, 3 lamps on 4L ballast SYLVANIA QUICKTRONIC SYSTEM 32 UNV electronic T8 ballasts offer several advantages: 1. [. . . ] Complete performance data is available in the QUICKSYSTEMS section of the SYLVANIA Electronic Ballast Catalog. Universal Voltage (120-277V) Item Number 49905 49941 49942 OSRAM SYLVANIA Description QTP1x32T8/UNV ISN-SC Banded Pack 10-Pack Pallet Pack Input Current (AMPS) Lamp Type Rated Ballast Input System Lumens No. of Factor System Mean Power Efficacy (lm) Lamps (BF) Lumens Lumens (W) (lm/W) BEF 1 2800 3000 2850 2725 2475 2800 3000 2850 2725 2475 2800 3000 2850 2725 2475 2800 3000 2850 2725 2475 1 1 1 1 1 2 2 2 2 2 3 3 3 3 3 4 4 4 4 4 0. 88 0. 88 0. 88 0. 88 0. 88 0. 88 0. 88 0. 88 0. 88 0. 88 0. 88 0. 88 0. 88 0. 88 0. 88 0. 88 0. 88 0. 88 0. 88 0. 88 2465 2640 2510 2400 2180 4930 5280 5015 4795 4355 7390 7920 7525 7195 6535 9855 10560 10030 9590 8710 2220 2480 2360 2255 2050 4435 4965 4715 4510 4095 6650 7445 7075 6760 6140 8870 9925 9430 9015 8190 30 30 28 26 23 59 59 55 52 46 86 86 81 76 67 112 112 105 98 88 82 88 90 91 95 84 89 91 92 95 86 92 93 95 98 88 94 96 98 99 2. 93 2. 93 3. 14 3. 38 3. 83 1. 49 1. 49 1. 60 1. 69 1. 91 1. 02 1. 02 1. 09 1. 16 1. 31 0. 79 0. 79 0. 84 0. 90 1. 00 0. 26/0. 11 FO32/700 0. 26/0. 11 FO32/XP 0. 25/0. 11 FO30/SS 0. 23/0. 10 FO28/SS 0. 20/0. 09 FO25/SS 0. 50/0. 21 FO32/700 0. 50/0. 21 FO32/XP 0. 46/0. 20 FO30/SS 0. 43/0. 19 FO28/SS 0. 39/0. 16 FO25/SS 0. 72/0. 31 FO32/700 0. 72/0. 31 FO32/XP 0. 69/0. 30 FO30/SS 0. 65/0. 28 FO28/SS 0. 58/0. 25 FO25/SS 0. 95/0. 40 FO32/700 0. 95/0. 40 FO32/XP 0. 91/0. 39 FO30/SS 0. 85/0. 37 FO28/SS 0. 74/0. 31 FO25/SS QTP2x32T8/UNV ISN-SC 49906 49943 49944 Banded Pack 10-Pack Pallet Pack Specifications Data based on F32T8 Starting Method: Instant Start Ballast Factor: 0. 88 Circuit Type: Parallel Lamp Frequency: >40kHz Lamp CCF: Less than 1. 7 Starting Temp:2 -20°F (-29°C) for OCTRON® T8 lamps; 60°F (16°C) for SUPERSAVER® T8 lamps 0°F (-18°C) for FO40T8 Input Frequency: 50/60 Hz Low THD: <10% Power Factor: >98% Voltage Range: ±10% of 120-277V rated line (108-305V) UL Listed Class P, Type 1 Outdoor CSA Certified 70°C Max Case Temperature 75°C Max Case Temp. (4-lamp model) FCC 47CFR Part 18 Non-Consumer Class A Sound Rating ANSI C62. 41 Cat. A Transient Protection GFCI compatible Emergency ballast compatible Remote Mounting (Max. wire length from ballast case to lampholder): · 20 ft: full wattage T8s · 10 ft: energy saving T8s · 4 ft: 25W energy saving T8s 2 Operation below 50°F (10°C) may affect light output or lamp operation ­ see "Low Temp. Starting" definition. QTP3x32T8/UNV ISN-SC 49907 49945 49946 Banded Pack 10-Pack Pallet Pack QTP4x32T8/UNV ISN-SC 49908 49947 49948 Banded Pack 10-Pack Pallet Pack Q TP T8 ISN Banded Pack, (add "-B" to Description). Banded Pack and 10-Pack contain 10 pieces each. Pallet Pack contains 840 pieces, (add "-PAL" to Description). [. . . ] OSRAM SYLVANIA National Customer Service and Sales Center 1-800-LIGHTBULB (1-800-544-4828) www. sylvania. com 29 QUICKTRONIC 4x32 Dimensions: Overall: 9. 5" L x 1. 68" W x 1. 18" H Mounting: 8. 90" Product Weight: 1. 6 lbs each (approx) Wiring: Leads only (no connectors provided) Height 8. 70 mm Slot Width Mounting Length Length Item Number QUICKTRONIC PROFESSIONAL Number of Lamps 49907 QTP 3 x 32T8 / UNV ISN - SC Case Size Starting/Ballast Factor Line Voltage (120-277V) Primary Lamp Wattage Specifications subject to change without notice. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE SYLVANIA QTP T8 ISN

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual SYLVANIA QTP T8 ISN will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag